HomeMy WebLinkAboutB16-0029_A111 - LEVEL 1 FINISH PLAN - DOORS - COMMON SPACE WINDOWS_1478906085.pdfDN
DN
UP
UP
DN
DN
FD FD
FD
FD
FD
FD
FD
FD FD
FD
FD
1
2
3
5
6
7
8
9
10
11
12
13
14
15
16
17
G
G
H
H
D
D
E
E
C
C
B-1
B-1
B
B
A
A
RR
QQ
PP
NN
I
I
F
F
J
J
K
K
BB
AA
CC
DD
EE
HH GG
FF
JJ
KK LL MM
NEW EXPOSED AGGREGATE
POOL DECK WITH SNOWMELT
9'-0"
20'-0"
20'-0"
20'-0"
23'-0"
23'-0"
23'-0"
23'-0"
22'-9"
25'-7"
26'-8" 5'-0" 12'-0" 16'-0" 25'-6" 25'-6" 19'-7" 12'-8 3/4" 14'-10 1/4" 5'-0" 12'-0"
174'-10"
44'-7"
23'-0"23'-0"
12'-0"5'-0"14'-10 1/4"12'-8 3/4"
13'-0"23'-0"
A404
1
A405
1
A407
1
A401
1
A410
1
32'-7 1/4"
32'-8 1/4"
RAMP DOWN RAMP DOWN
LA ROCHE
PORCELAIN TILE
OR
BORDEAUS GRIS
LIMESTONE
IN BIRGOGNE
PATTERN (SEE
HOA SCOPE
PLANS)
UUU
XXX
ZZZ
NEW ENTRY
ROOF AND
VESTIBULE
NEW 90DEG
HOLD OPEN
DOORS FOR
STAIRWELL TO
LOBBY
REMOVE WINDOWS IN STAIR TOWER;
FRAME OPENING AND FINISH W/ TWO LAYERS GYP.
INTERIOR AND PLYWOOD WITH WATER RESISTANT
MEMBRANE EXTERIOR
REMOVE WINDOWS IN STAIR TOWER;
FRAME OPENING AND FINISH W/ TWO LAYERS GYP.
INTERIOR AND PLYWOOD WITH WATER RESISTANT
MEMBRANE EXTERIOR
UNIT
111
UNIT
105
UNIT
113LL
UNIT
109LL
UNIT
107LL
UNIT
103LL
UNIT
101
UNIT
102
UNIT
104
UNIT
106
UNIT
115
REPLACE/REFURBISH BUILDING UTIILITY
DOORS
WITH IN-KIND HARDWARE AND RATING
(TYP. FOR "BUILDING STANDARD UTILITY
DOORS
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOORS
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
CARPET
CARPET
STAIR
02
STAIR
05
STAIR
06
STAIR
09
STAIR
10
STAIR
01
WD-02
UNIT ABOVE
321
SD-02
SD-01
WD-03
SD-06
HM-01
SF-01
WD-07
HM-04 HM-05
HM-03
SD-03
GD-01 GD-02
SD-04
SG-01
GD-03
HM-10
GD-04
HM-07
HM-06
HM-08
HM-02
HM-09
PG-01
BUILDING STANDARD
UTILITY DOOR
STAIR
07
WD-01
CW-09
ALL EXISTING FEATURES OF THE
CURRENT LOCKERS ROOMS TO BE
DEMOLISHED
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
2/22/2016 2:22:23 PM
A111
LEVEL 1 FINISH
PLAN / DOORS /
COMMON SPACE
WINDOWS
VAIL SPA
CONDOMINIUMS
MEW
MEW
02/19/2016
VSRP - 2016
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1 LEVEL 1 FINISH PLAN
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13.
SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE
DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS
SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR
SIZE AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED
IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR
KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON
PLANS
12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY
CONSTRUCTED TO MATCH EXISTING, U.N.O
13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
14. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER STRUCTURAL DRAWINGS
15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATE OR MATCH EXISTING
16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR
TRANSITIONS
17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR
LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT
BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN
AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED
BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN.
CLEAR HEIGHT
18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBL
No. Description Date
1 PROGRESS/PRICIN
G
2 OCT
15
2 DRB REVIEW 12 OCT
15
3 PROGRESS/PRICIN
G 2
23 DEC
15
4 CDs/PERMIT 21 JAN
16
5 CDs/PERMIT 2 19 FEB
16
COMMON AREA AND BUILDING STANDARD DOORS
Mark Hardware
Fire
Rating Comments
Cont
ract
1002 Passage w Lock N/A Solid core, flush, sound sealed 2016
1003 Passage w Lock N/A Solid core, flush 2016
1004 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
1005 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016
1006 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016
1008 Passage w Lock N/A Solid core, flush, sound sealed 2016
1009 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016
1010 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016
1011 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
1012 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
1013 Passage w Lock N/A Solid core, flush 2016
1014 Handle, deadbolt N/A Solid core, flush 2016
1015 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
1016 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
1017 Passage w Lock N/A Solid core, flush 2016
1018 Passage w Lock N/A Re-use existing stall door, refinish, new
hardware
2016
GD-01 Handle, deadbolt,
keypad
N/A Tempered, frameless glass, pivot hinges,
keypad
2016
GD-02 Handle, deadbolt,
keypad
N/A Tempered, frameless glass, pivot hinges,
keypad
2016
GD-03 Handle, deadbolt,
keypad
N/A Tempered, frameless glass, pivot hinges,
keypad
2016
GD-04 Handle, deadbolt,
keypad
N/A Tempered, frameless glass, pivot hinges,
keypad
2016
HM-01 Egress, master lock N/A Flush Hollow Metal - egress hardware,
refinish
2016
HM-02 Egress, master lock 90m Flush Hollow Metal - egress hardware,
refinish
2016
HM-03 Storage, keypad lock N/A Flush Hollow Metal -keypad and master key,
refinish
HOA
HM-04 Storage, keypad lock N/A Flush Hollow Metal -keypad and master key,
refinish
HOA
HM-05 Passage and keypad 90m Flush Hollow Metal -keypad and master key,
refinish
2016
HM-06 Passage, Deadbolt 90m Flush Hollow Metal - with venting, seals HOA
HM-07 Passage and keypad 90m Flush Hollow Metal -keypad and master key,
refinish
2016
HM-08 Passage, Deadbolt 90m Double Flush Metal - deadbolt, refinish HOA
HM-09 Panic Egress, lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-10 Panic Egress, lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-12 Panic Egress, lock 90m Flush Hollow Metal - egress hardware,
refinish
2016
HM-13 Handle, deadbolt N/A Flush Hollow Metal - passage, deadbolt,
refinish
2016
HM-14 Handle, deadbolt N/A Double Flush Metal - deadbolt, refinish 2016
HM-15 Handle, deadbolt N/A Double Flush Metal - deadbolt, refinish 2016
HM-16 Passage and keypad 120m Flush Hollow Metal -keypad and master key,
refinish
2016
HM-17 Egress, master lock N/A Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-18 Panic Egress, lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-19 Handle, deadbolt 90m Double Flush Metal - deadbolt, seals,refinish HOA
HM-20 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-21 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-22 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-23 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-24 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-25 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-26 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-27 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-28 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-29 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-30 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
HM-31 Egress, master lock 120m Flush Hollow Metal - egress hardware,
seals,refinish
2016
SD-01 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SD-02 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SD-03 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SD-04 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SD-05 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SD-06 Mag Hold-opens,
egress
20m Wood/glass, smoke seals, mag hold-opens 2016
SF-01 Egress, master lock N/A Storefront system door 2016
SG-01 Motion Slide, keypad N/A Storefront system door 2016
WD-01 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-02 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-03 Egress, master lock,
keypad
N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-04 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-05 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-06 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-07 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-08 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-09 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-10 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
WD-11 Egress, master lock N/A Jeld-wen provided (See Window and Door
Package)
2016
COMMON WINDOW LOCATIONS NOTED ON PLAN - SEE WINDOW PROVIDERS PACKAGE FOR MORE INFORMATION
SEE A603 FOR PG-01 INFORMATION
04/13/16