Loading...
HomeMy WebLinkAboutB16-0029_A111 - LEVEL 1 FINISH PLAN - DOORS - COMMON SPACE WINDOWS_1479389480.pdfDN DN UP UP DN DN FD FD FD FD FD FD FD FD FD FD FD 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 G G H H D D E E C C B-1 B-1 B B A A RR QQ PP NN I I F F J J K K BB AA CC DD EE HH GG FF JJ KK LL MM NEW EXPOSED AGGREGATE POOL DECK WITH SNOWMELT 9'-0" 20'-0" 20'-0" 20'-0" 23'-0" 23'-0" 23'-0" 23'-0" 22'-9" 25'-7" 26'-8" 5'-0" 12'-0" 16'-0" 25'-6" 25'-6" 19'-7" 12'-8 3/4" 14'-10 1/4" 5'-0" 12'-0" 174'-10" 44'-7" 23'-0"23'-0" 12'-0"5'-0"14'-10 1/4"12'-8 3/4" 13'-0"23'-0" A404 1 A405 1 A407 1 A401 1 A410 1 32'-7 1/4" 32'-8 1/4" RAMP DOWN RAMP DOWN LA ROCHE PORCELAIN TILE OR BORDEAUS GRIS LIMESTONE IN BIRGOGNE PATTERN (SEE HOA SCOPE PLANS) UUU XXX ZZZ NEW ENTRY ROOF AND VESTIBULE NEW 90DEG HOLD OPEN DOORS FOR STAIRWELL TO LOBBY REMOVE WINDOWS IN STAIR TOWER; FRAME OPENING AND FINISH W/ TWO LAYERS GYP. INTERIOR AND PLYWOOD WITH WATER RESISTANT MEMBRANE EXTERIOR REMOVE WINDOWS IN STAIR TOWER; FRAME OPENING AND FINISH W/ TWO LAYERS GYP. INTERIOR AND PLYWOOD WITH WATER RESISTANT MEMBRANE EXTERIOR UNIT 111 UNIT 105 UNIT 113LL UNIT 109LL UNIT 107LL UNIT 103LL UNIT 101 UNIT 102 UNIT 104 UNIT 106 UNIT 115 REPLACE/REFURBISH BUILDING UTIILITY DOORS WITH IN-KIND HARDWARE AND RATING (TYP. FOR "BUILDING STANDARD UTILITY DOORS BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOORS BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOOR CARPET CARPET STAIR 02 STAIR 05 STAIR 06 STAIR 09 STAIR 10 STAIR 01 WD-02 UNIT ABOVE 321 SD-02 SD-01 WD-03 SD-06 HM-01 SF-01 WD-07 HM-04 HM-05 HM-03 SD-03 GD-01 GD-02 SD-04 SG-01 GD-03 HM-10 GD-04 HM-07 HM-06 HM-08 HM-02 HM-09 PG-01 BUILDING STANDARD UTILITY DOOR STAIR 07 WD-01 CW-09 ALL EXISTING FEATURES OF THE CURRENT LOCKERS ROOMS TO BE DEMOLISHED Scale Date Drawn By Checked By Project Number 1/16" = 1'-0" 2/22/2016 2:22:23 PM A111 LEVEL 1 FINISH PLAN / DOORS / COMMON SPACE WINDOWS VAIL SPA CONDOMINIUMS MEW MEW 02/19/2016 VSRP - 2016 710 W. LIONSHEAD CIRCLE 1/16" = 1'-0" 1 LEVEL 1 FINISH PLAN GENERAL PLAN NOTES 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. 2. FURNITURE IS NIC, U.N.O. 3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES AND GARAGE AND OTHER UNCONDITIONED AREAS. 4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13. 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL BE COORDINATED WITH STRUCTURAL. 7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT PERPENDICULAR WALL SHALL BE 4" U.N.O. 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES & GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. BARRIER ON EXT. WHERE SIDING SHOWN). 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04. 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON PLANS 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY CONSTRUCTED TO MATCH EXISTING, U.N.O 13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM NOTED FROM FACE OF FINISH TO FACE OF FINISH. 14. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED PER STRUCTURAL DRAWINGS 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR RATE OR MATCH EXISTING 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR TRANSITIONS 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBL No. Description Date 1 PROGRESS/PRICIN G 2 OCT 15 2 DRB REVIEW 12 OCT 15 3 PROGRESS/PRICIN G 2 23 DEC 15 4 CDs/PERMIT 21 JAN 16 5 CDs/PERMIT 2 19 FEB 16 COMMON AREA AND BUILDING STANDARD DOORS Mark Hardware Fire Rating Comments Cont ract 1002 Passage w Lock N/A Solid core, flush, sound sealed 2016 1003 Passage w Lock N/A Solid core, flush 2016 1004 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 1005 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016 1006 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016 1008 Passage w Lock N/A Solid core, flush, sound sealed 2016 1009 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016 1010 Handle, no lock N/A Tempered, frameless glass, pivot hinges 2016 1011 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 1012 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 1013 Passage w Lock N/A Solid core, flush 2016 1014 Handle, deadbolt N/A Solid core, flush 2016 1015 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 1016 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 1017 Passage w Lock N/A Solid core, flush 2016 1018 Passage w Lock N/A Re-use existing stall door, refinish, new hardware 2016 GD-01 Handle, deadbolt, keypad N/A Tempered, frameless glass, pivot hinges, keypad 2016 GD-02 Handle, deadbolt, keypad N/A Tempered, frameless glass, pivot hinges, keypad 2016 GD-03 Handle, deadbolt, keypad N/A Tempered, frameless glass, pivot hinges, keypad 2016 GD-04 Handle, deadbolt, keypad N/A Tempered, frameless glass, pivot hinges, keypad 2016 HM-01 Egress, master lock N/A Flush Hollow Metal - egress hardware, refinish 2016 HM-02 Egress, master lock 90m Flush Hollow Metal - egress hardware, refinish 2016 HM-03 Storage, keypad lock N/A Flush Hollow Metal -keypad and master key, refinish HOA HM-04 Storage, keypad lock N/A Flush Hollow Metal -keypad and master key, refinish HOA HM-05 Passage and keypad 90m Flush Hollow Metal -keypad and master key, refinish 2016 HM-06 Passage, Deadbolt 90m Flush Hollow Metal - with venting, seals HOA HM-07 Passage and keypad 90m Flush Hollow Metal -keypad and master key, refinish 2016 HM-08 Passage, Deadbolt 90m Double Flush Metal - deadbolt, refinish HOA HM-09 Panic Egress, lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-10 Panic Egress, lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-12 Panic Egress, lock 90m Flush Hollow Metal - egress hardware, refinish 2016 HM-13 Handle, deadbolt N/A Flush Hollow Metal - passage, deadbolt, refinish 2016 HM-14 Handle, deadbolt N/A Double Flush Metal - deadbolt, refinish 2016 HM-15 Handle, deadbolt N/A Double Flush Metal - deadbolt, refinish 2016 HM-16 Passage and keypad 120m Flush Hollow Metal -keypad and master key, refinish 2016 HM-17 Egress, master lock N/A Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-18 Panic Egress, lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-19 Handle, deadbolt 90m Double Flush Metal - deadbolt, seals,refinish HOA HM-20 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-21 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-22 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-23 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-24 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-25 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-26 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-27 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-28 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-29 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-30 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 HM-31 Egress, master lock 120m Flush Hollow Metal - egress hardware, seals,refinish 2016 SD-01 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SD-02 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SD-03 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SD-04 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SD-05 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SD-06 Mag Hold-opens, egress 20m Wood/glass, smoke seals, mag hold-opens 2016 SF-01 Egress, master lock N/A Storefront system door 2016 SG-01 Motion Slide, keypad N/A Storefront system door 2016 WD-01 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-02 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-03 Egress, master lock, keypad N/A Jeld-wen provided (See Window and Door Package) 2016 WD-04 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-05 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-06 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-07 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-08 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-09 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-10 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 WD-11 Egress, master lock N/A Jeld-wen provided (See Window and Door Package) 2016 COMMON WINDOW LOCATIONS NOTED ON PLAN - SEE WINDOW PROVIDERS PACKAGE FOR MORE INFORMATION SEE A603 FOR PG-01 INFORMATION 04/13/16