HomeMy WebLinkAboutB16-0029_A411 - STANDARD MOUNTING HEIGHTS - ADA_1478906156.pdf5' - 0"
MOP HOLDER 2' - 8"
3' - 2" 4' - 0"
3' - 7"
5' - 5"
5' - 10"
3' - 4" MAX.
3' - 6" 2' - 8" MAX. 3' - 2" MIN. 2' - 6"
6" MAX.
4' - 0" MIN.
6" MAX. 6" MAX. 3' - 2" MIN. 2" MAX.
3' - 10" MIN. 3' - 2" MIN.
2' - 8" MAX. 8" MAX.
4' - 10" MIN.
2' - 0" MIN. TO TOP 2' - 9"
TO 3' - 0"
9"
1' - 0" MAX.
5' - 0"
2' - 0" MAX. 2' - 0" MIN.
TO TOP
2' - 9"
TO 3' - 0"
1' - 0" MIN.
HEAD END CONTROL
END
GRAB BARS AT TUB
(WITHOUT PERMANENT SEATS)
GRAB BAR REINFORCEMENT AT TOILET
(ADAPTABLE UNITS)
GRAB BAR REINFORCEMENT AT TUB
(ADAPTABLE UNITS)
GRAB BAR REINF. AT
SHOWER (ADAPTABLE UNITS)
TOWEL BAR MEDICINE
CABINET
SHELF & ROD SHELF & ROD
ALL WALLS,
TYPICAL
CONTROL
END: (HEAD
END SIM)
CONTROL VALVE AREA
HAND-HELD
SHOWER
SPRAY UNIT
W/ 60" HOSE
CONTROL VALVE
AREA
SEAT
GRAB BARS
SEAT
REFLECTIVE SURFACE
3' - 4"
MAX. BOTT
. OF
T.O. TOWEL SLOT
4' - 0" MAX.
T.O. COIN SLOT 4' - 0" MAX
1' - 7" MIN.
2' - 6" MAX.
T. O. SLOT 4' - 0" MAX. MIRROR PAPER TOWEL
DISPENSER
NAPKIN/TAMPON
VENDOR
NAPKIN DISPOSAL TOILET SEAT
COVER DISPENSER
SHELF SOAP DISPENSER ROBE HOOKS 4' - 0" MAX.
PUSH BUTTON 4' - 0" MAX. TO
4' - 0"
1' - 0"
9" MIN.
6" MAX.
8" MIN. 2' - 5" MIN.
2' - 10"
MAX.
1' - 5" MIN.
LAVATORY
1' - 3" MIN.
T.O. RIM
1'- 5"
MAX T.O. RIM
1' - 8"
T. O. HANDLE
3' - 8 1/32" MAX.
15" - 19"
T.O. SEAT - TYPE A & B UNITS
17" - 19"
T.O. SEAT PUBLIC ACCESS
1' - 3" MIN. 7"-9"
1 1/2" MIN. 1' - 0" 3' - 6"
TO TOP
2' - 9" TO 3' - 0"
39" - 41"
1' - 6"
39" - 41" GRAB BARS AND TOILET
TISSUE DISPENSER
17" - 19" AMBULATORY
16" - 18" ACCESSIBLE
2' - 0" 1' - 0"
REAR GRAB BAR @
WHEELCHAIR
ACCESSIBLE
CONFIGURATIONS
SIDEWALL
GRAB BARS.
PROVIDE ON
EACH SIDE OF
AMBULATORY
STALL
INSULATE ALL
EXPOSED
PIPING
URINAL SHOWER
BACK WALL
SHOWER
CONTROL WALL
FOLDING SHOWER
SEAT PLAN
DRINKING FOUNTAINS 1' - 7"
1' - 5" TO 3" TO 6"
4' - 0" MAX.
5' - 0"
1' - 3"
MAX.
1' - 3"
CONTINUOUS
GRAB BAR
FOLDING
SHOWER SEAT
CONTROL
VALVE
AREA
HAND-HELD
SHOWER SPRAY
UNIT W/ 60" HOSE
14" - 15"
3' - 0"
15" - 16"
22" - 23"
17" - 19"
2' - 3" MIN.
MIN.
9"
6" MAX
MIN.
8"
T.O. SPOUT
3' - 4"
6"
3' - 6"
3' - 2"
LIGHT SWITCH
DOOR LEVER
6' - 8" 4' - 0"
DOOR & DEVICES
WALL OUTLET
THERMOSTAT, PHONE,
FIRE ALARM PULL
STATION, HC DOOR
BUTTON OR CARD
READER, IF NOT
OBSTRUCTED
FIRE ALARM
SPEAKER/STROBE
6' - 8" TO 8' - 0"
1' - 6"
ELEVATOR CONTROLS ELEVATOR CAR CONTROLS ROOM SIGN OUTLET AT COUNTER FIRE EXTINGUISHER
CABINET
MAIL DROP MAIL BOX
IN FIRE
EMERGENCY
DO NOT USE
ELEVATOR
USE STAIRS
FIREFIGHTERS OPERATION
TO RE CALL ELEVA TORS
INSERT FIRE KEY AND TURN T O "ON"
NORMAL OPERATION
KEY BYPASS, THEN KEY "OFF"
OFF O
N
B
Y
P
A
S
S
FIRE
6' - 0" MIN.
5' - 0"
3' - 6"
RAISED &
BRAILLE
CHARACTERS
ON HOISTWAY
JAMB
CALL BUTTON
HALL LANTERN
CONTROL INDICATORS
RAISED & BRAILLE
CHARACTERS (5/8" MIN)
FLOOR BUTTONS
4' - 6" MAX.CONTROL BUTTONS
2' - 11"
MAX.
COMPLY W/ 703.2.9 & TABLE 703.2.4
5' - 0"
9"
3' - 4" - CAB. DEPTH 20" - 25"3' - 8" - CAB. DEPTH < 20"
T.O. HANDLE
4' - 0" MAX.
& TOP OF DROP LIP
4' - 0" MAX T.O. HANDLE
TO PATRON LOCK
5' - 7 1/32" MAX.
2' - 4" MIN.
1 1/2"
MAX.
GENERAL NOTES
1. DIMENSIONS GIVEN ARE COMPLIANT WITH ANSI A117.1-2003.
2. NOT ALL FIXTURES AND DEVICES INDICATED MAY BE USED IN THE PROJECT.
3. INSTALL GRAB BARS TO WITHSTAND A DOWNWARD LOAD OF 250 LBF WHEN
TESTED ACCORDING TO METHODS IN ASTM F-446.
4. ACCESSORIES IN BATHING AREAS THAT PROJECT MORE THAN 1" BEYOND
FINISHED SURFACES SHALL BE INSTALLED TO WITHSTAND A DOWNWARD LOAD
OF 250 LBF WHEN TESTED ACCORDING TO METHODS IN ASTM F-446.
5. MOUNTING HEIGHTS INDICATED MAY BE SUPERCEDED BY MORE SPECIFIC
INFORMATION ELSEWHERE IN THE DOCUMENTS.
6. ALL APPLIANCES AND PLUMBING FIXTURES MUST COMPLY WITH APPLICABLE
ANSI AND ADA REQUIREMENTS.
7. DOOR THRESHOLDS MUST HAVE A MAXIMUM HEIGHT OF 1/2" WITH A 1:2 BEVEL.
8. ALL ACCESSIBLE SINKS SHALL HAVE A MAXIMUM HEIGHT OF 34" TO THE RIM
OR COUNTER (WHICHEVER IS HIGHER) AND PROVIDE A 27" MINIMUM HIGH KNEE
SPACE.
9. PROVIDE AND INSTALL BLOCKING / REINFORCEMENT FOR ALL ACCESSORIES
PER MANUFACTURER'S INSTRUCTIONS.
10. PROVIDE AND INSTALL BLOCKING IN ALL ADAPTIVE USE SPACES.
1' - 6"
4" MAX. 3" TO 6"
1' - 6" MIN.
3' - 0"
TO FINISHES
3' - 0" MIN.
TO TOP
2' - 9"
TO 3' - 0"
4" MAX.
1' - 6" MIN. MAX.
1' - 3"
3' - 2" MIN.
2 1/2" MAX.
3" MAX.
2" MAX.
3' - 10" MIN. 3' - 2" MAX. 2' - 8" MIN. GRAB BAR REINFORCEMENT AT TOILET 3' - 6"
2' - 8"
3' - 2" GRAB BAR REINF.
@ SHOWER
TOWEL BAR
ALL
WALLS
TYPICAL
LEGEND
ACCESSIBLE
4" MAX. PROTRUSION
2' - 10"
4' - 0" MIN.
5' - 0" MAX.
TACTILE
AREA OF
REFUGE
SIGNAGE
2' - 0"
2' - 0"
TO TOP
2' - 9"
TO 3' - 0" 6"
VERT.
REINFORCEMENT
@ CONTROL END
ONLY
6"
VERTICAL
REINFORCEMENT
@ CONTROL END
ONLY
ACCESSIBLE LAV.
2' - 10"
6"
2' - 0"
PARCEL BOX
36" - 48" MAX.
INTERIOR
1' - 3"
MIN. B.O.
3' - 1" 6" 2' - 0"
8" MAX.
4' - 10" MIN.
3' - 1" 6"
2' - 0" 2" MAX.
3' - 4" MIN.
3' - 8" MIN. 2' - 8" MAX.
8" MAX.
4' - 2" MIN.
FOLDING GRAB BAR REINFORCEMENT AT
TOILET (ADAPTABLE UNITS)
2' - 8" 6" MIN.
1' - 0"
VERIFY WITH MANUFACTURER
SPECIFIC REINFORCING
REQUIREMENTS
2' - 8" MAX. 3' - 2" MIN. MIN.
2' - 0"
MIN.
2' - 0"
TOILET AT CENTER
2' - 0" MIN.
TO TOP
2' - 9"
TO 3' - 0"
9" 1' - 0" MAX.
RECESSED WIDTH
1' - 3" MAX.
HEAD END CONTROL
END
GRAB BARS AT TUB
(WITH PERMANENT SEATS)
HAND-HELD
SHOWER
SPRAY UNIT
W/ 60" HOSE
SEAT
GRAB BARS
4" MAX.
3" TO 6"
1' - 6" MIN.
TO TOP
2' - 9"
TO 3' - 0"
BACK WALL
2' - 8" MAX.
3' - 2" MIN.
MIN.
2' - 0"
MIN.
2' - 0"
TOILET AT CENTER
EXTERIOR DOOR THRESHOLD DETAILS
MAX. ALLOWABLE HEIGHT DIFFERENCE
BETWEEN INT. FLOOR LEVEL AND EXT. FLOOR LEVEL
LEVEL DIFFERENCE AT PRIMARY ENTRY DOOR:
0" PERVIOUS CONSTRUCTION
(WOOD DECKING)
1/2" IMPERVIOUS CONSTRUCTION
(CONCRETE)
LEVEL DIFFERENCE AT SECONDARY ENTRY DOOR:
1/2" PERVIOUS CONSTRUCTION
(WOOD DECKING)
4" IMPERVIOUS CONSTRUCTION
(CONCRETE)
3/4" MAX
1 1/2" MIN
1/2" MAX
1 1/2" MIN
1/4" MAX
2 1/2" MIN AT 1:2
3/4" MAX
3/4" MAX
1/2" MAX
1 1/4" MAX
Scale
Date
Drawn By
Checked By
Project Number
1/2" = 1'-0"
2/22/2016 2:30:25 PM
A411
STANDARD
MOUNTING HEIGHTS
- ADA
VAIL SPA
CONDOMINIUMS
MEW
MEW
02/19/2016
VSRP - 2016
710 W. LIONSHEAD CIRCLE
1/2" = 1'-0"
1
STANDARD MOUNTING HEIGHTS
No. Description Date
1 CDs/PERMIT 2 19 FEB
16
04/13/16