Loading...
HomeMy WebLinkAboutB16-0029_E2.0_1479389570.pdfTELDAT W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S. W.S.W.S.W.S. 4OUTL 2OUTL 4OUTL CLOCK OUTLET W.S. W.S. NOTE : ALL EXPOSED CONDUIT IN FITNESS ROOM TO BE RE- ROUTED INTO WALLS COMPUTER STATION UP DN FD FD FD FD FD FD FD FDFD FD FD FD FD FD FD FD G D E C F HH JJ KK ADA POOL LIFT LANDSCAPE AREA CONCPAVERS CONCPAVERS DOWN DOWN DOWN DOWN DOWN DOWN DOWN METAL FENCE METAL FENCE POLE LIGHT POLE LIGHT POLE LIGHT POLE LIGHT POLE LIGHT POLE LIGHT STEP LIGHT STEP LIGHT STEP LIGHTSTEP LIGHTSTEP LIGHTSTEP LIGHT STEP LIGHT STEP LIGHT STEP LIGHTSTEP LIGHT STEP LIGHTSTEP LIGHT STEP LIGHT STEP LIGHT STEP LIGHT STEP LIGHT STEP LIGHT S TEP LIGHT STEP LIGHT STEP LIGHT STEP LIGHT S TEP LIGHT STEP LIGHT 200 AMP PANEL BELOW NOTE: ALL POOL AREA LIGHTING TO BE WIRED TO VAULT 200 S TEP LIGHT STEP LIGHT F ADA SAUNA 9 ADA STEAMROOM 10 ADA TOILET 12 URINAL 13 SHOWER 14 ADA SHOWER 15 MEN'S MASSAGE 16 42' - 9" 42' - 9" 42' - 9" 42' - 9" RECESSED CAN LIGHTING THROUGHOUT RECESSED CAN LIGHTING THROUGHOUT RECESSED CAN LIGHTING THROUGHOUT EXISTING STRUCTURAL COLUMN TO REMAIN NOTE: LOCATE EXISTING HVAC SUPPLY & RETURNS, TO REMAIN EXISTING STRUCTURAL COLUMN TO REMAIN SLOPE 1/8"/12" MASTER DIM W. SCONCE. HEATER GFI W. SCONCE. W. SCONCE. SAUNA CONTROLS STEAM LIGHT CONTACTOR CONTROL BOX FOR SAUNA GFI GFI STEAMER CLOSET REMOVABLE ACCESS PANEL ON WALL FACE TO 400 AMP PANEL IN WOMENS LOCKER ROOM EXIT MOTION ADA SAUNA 1 ADA STEAM ROOM 2 ADA TOILET 3 TOILET 4 WOMEN'S LOCKER ROOM 5 WOMEN'S MASSAGE 6 ADA SHOWER 7 SHOWER 8 RECESSED CAN LIGHTING THROUGHOUT RECESSED CAN LIGHTING THROUGHOUT NOTE: LOCATE EXISTING HVAC SUPPLY & RETURNS, TO REMAIN EXISTING STRUCTURAL COLUMN TO REMAIN 42' - 9" 42' - 9" 42' - 9" 42' - 9" SLOPE 1/8"/12" MASTER DIM W. SCONCE. CONTACTOR CONTROL BOX FOR SAUNA SAUNA CONTROL STEAMER CONTROL GFI GFI PANEL BOX GFI HEATER W. SCONCE. GFI GFI W. SCONCE. 400 AMP PANEL GFI EMERGENCY LIGHT EXIT MOTION PANEL P PANEL P1 TO P-4 5 A, 120V P-15 TO P-3 5 A, 120V P-15 TO B-2 & P-2 10 A, 120V P-13 TO B-1 & P-1 10 A, 120V P-11 AT MECHANICAL ROOM CONNECT WS FIXTURES AT CORRIDOR, POOL AND EXERCISE ROOM TO EXISTING LIGHTING CIRCUIT. EXISTING LIGHTING CIRCUIT HAS (10) 150W FIXTURES REMOVED, (19) 25 WATT FIXTURES ADDED FOR A NET POWER REDUCTION OF 1025 WATTS ON THE EXISTING LIGHTING CIRCUIT. PANEL POOL PROVIDE NEW CIRCUITS AT POOL PANEL AS FOLLOWS: (2) 20A1P GFI CIRCUITS, POOL-40,42 FOR LANDSCAPE LIGHTING (1) 20A1P CIRCUIT, POOL-30 FOR BOILER AND FRACTIONAL HP PUMPS (1) 20A1P, POOL-32 FOR CONTROLLER P1-19,21 SAUNA 8KW, 240V 50A2P PROVIDE (3#6 CU, #10 CU G)1"C & 50A2P BREAKER P1-20,22 SAUNA 8KW, 240V 50A2P PROVIDE (3#6 CU, #10 CU G)1"C & 50A2P BREAKER P1-44,46 STEAM SHOWER 116 FLA, 208V 1P PROVIDE (3#1/0 CU, #6 CU G)1-1/2"C & 150A2P BREAKER 5A 120V CONTROL P1-8 P1-1 P1-3 P1-4 P1-6 CONNECT MEN'S LIGHTING TO P1-2 CONNECT WOMEN'S LIGHTING TO P1-2 REUSE EXISTING CIRCUIT REUSE EXISTING CIRCUIT PROVIDE GFI PROTECTION FOR POOL LIGHTS 500W 120V 1P WALL HTRS P1-7 GENERAL NOTE: REFERENCE THIS PLAN FOR POWER PLANNING ONLY. REFERENCE ARCHITECTURAL PLANS FOR LIGHTING DESIGN. POOL & SPA NOTES 1. COORDINATE GROUNDING WITH POOL/SPA CONTRACTOR TO ENSURE ALL METAL PARTS WITHIN 5'-0" HORIZONTALLY OF POOL/SPA INSIDE WALLS ARE GROUNDED AND APPROPRIATE BONDING LOCATIONS ARE ESTABLISHED. ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH THE POOL/SPA INCLUDING PANELBOARDS, CONDUIT, JUNCTION BOXES, MOTORS, ETC. SHALL BE GROUNDED PER NEC 680.6. 2. UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL/SPA OR THE AREA EXTENDING 5'-0" HORIZONTALLY FROM THE INSIDE WALLS OF THE POOL/SPA UNLESS NECESSARY TO SUPPLY ASSOCIATED EQUIPMENT IN THIS AREA PERMITTED BY CODE. REF NEC 680.10. 3. ALL OUTLETS SUPPLYING POOL/SPA EQUIPMENT SHALL BE GFI PROTECTED. REF NEC 680.21(C). 4. CIRCULATION/SANITATION MOTOR RECEPTACLES SHALL BE LOCATED A MINIMUM OF 10'-0" FROM THE INSIDE WALLS OF THE POOL/SPA. ALL OTHER RECEPTACLES SHALL BE A MINIMUM OF 6'-0" FROM THE INSIDE WALLS OF THE POOL/SPA, MEASURED BY CORD LENGTH. ALL 120V RECEPTACLES BEYOND 6'-0" AND WITHIN 20'-0" OF THE POOL/SPA SHALL HAVE GFI PROTECTION. DISTANCES MEASURED BY CORD LENGTH. REF NEC 680.22(A). 5. NO LIGHTS SHALL BE ALLOWED UNDER 5'-0" AFG WITHIN 5'-0" HORIZONTALLY FROM THE INSIDE WALLS OF THE POOL/SPA. LIGHTS UNDER 5'-0" AFG BEYOND 5'-0" AND WITHIN 10'-0" HORIZONTALLY SHALL HAVE GFI PROTECTION. REF NEC 680.22(B). 6. REFERENCE NEC 680.26 FOR DETAILED BONDING REQUIREMENTS. PROVIDE #8 GROUNDING CONDUCTORS TO BOND THE FOLLOWING, BUT NOT LIMITED TO THE FOLLOWING: 6.1. CONDUCTIVE POOL SHELLS 6.2. POOL/SPA PERIMETER SURFACE WITHIN 3'-0" HORIZONTALLY FROM INSIDE WALLS OF POOL/SPAS 6.3. ALL METALLIC COMPONENTS OF THE POOL/SPA STRUCTURE 6.4. WET NICHE LIGHT FIXTURE SHELL/MOUNTING BRACKETS 6.5. ASSOCIATED METAL FITTINGS ATTACHED TO THE POOL/SPA STRUCTURE 6.6. ALL METAL PARTS OF POOL/SPA EQUIPMENT AND ELECTRICAL EQUIPMENT 6.7. ALL FIXED METAL PARTS SUCH AS METAL SHEATHED CABLES/RACEWAYS, METAL PIPING/AWNINGS/FENCES/WINOW AND DOOR FRAMES, ETC. 6.8. POOL WATER WITH A MINIMUM CONDUCTIVE SURFACE AREA OF 9 SQ. IN. 7. FOR ALL SPA INSTALLATIONS OTHER THAN SINGLE-FAMILY DWELLINGS, A CLEARLY LABELED EMERGENCY SHUTOFF SWITCH SHALL BE PROVIDED WITHIN SIGHT OF AND ADJACENT TO THE SPA, A MINIMUM OF 5'-0" AWAY FROM THE SPA, TO SHUT OFF ALL CIRCULATION AND JET PUMPS. REF NEC 680.41. of Drawn By: Checked By: DATE: ISSUE: PROGRESS AEC PROJECT #: VAIL SPA CONDOMINIUMS 710 W. LIONSHEAD CIRCLE 16057 07/25/16 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV PERMIT 07/29/16 51* #'% .'8'.  '.'%64+%#. 2.#0 '   NORTH LEVEL 1 ELECTRICAL PLAN SCALE: 3/16" = 1'0" 11/16/16