HomeMy WebLinkAboutB16-0029_E2.01_1478906188.pdf(LBS) WT. OPER. REMARKS SERVICE TOTAL CLG. TYPE COMPRESSOR DATA NOM. TONS FPI EVAPORATOR DATA # ROWS TAG UNIT MANUFACTURER & MODEL NO. LOCATION LEVEL NOISE (dBA) ELECTRICAL DATA HZ V PH MCA OR APPROVED EQUIVALENT POOL ROOM 108 70.1 3 10 8 SCROLL X 900 230 60 1 INDOOR CONSTRUCTION, VERTICAL DISCHARGE, & WATER FLOW SWITCH. PROVIDE CERTIFIED TRAINED TECHNICIAN STARTUP. PROVIDE REMOTE AIR COOLED CONDENSER (CU-1). DEHUMIDIFICATION (MBH) SENS. CLG. (MBH) CAPACITIES 35.8 DEHUMID. (LBS/HR) $7 ƒ $1'  5+ ,1'225 74 BLOWER DATA ESP 3500 0.8 HP @ ESP 3 @ 1" TOTAL CFM O.A. CFM 800 (LBS) WT. OPER. REMARKS SERVICE CLG. CAP. CONDENSER DATA TAG UNIT MANUFACTURER & MODEL NO. LOCATION LEVEL NOISE (dBA) ELECTRICAL DATA HZ V PH MCA OR APPROVED EQUIVALENT CU POOL ROOM DESERT AIRE RC SERIES 75 2 @ 1/2 SEE PLANS 61.5 329 230 60 1 XXX XXX XXX 1 DEHUMIDIFICATION (MBH) FAN HP 11 X 95 SEER REFRIG TYPE 410A AMBIENT 7(03 ƒ HTG. (MBH) 59.3 DHU 1 FOR LOCATION TAG UNIT MANUFACTURER & MODEL NO. PUMP SCHEDULE SERVICE LOCATION TYPE GPM TOTAL HEAD RPM REMARKS ELECT. DATA HP V PH HZ OPER. WT. (LBS) MAX. (FT) OR APPROVED EQUIVALENT CIRCULATOR 10 10.0 INTERLOCK W/ DHU-1 TSTAT. HWC-1 UP 26-64F GRUNDFOS P 1 POOL EQUIP. ROOM 1/12 X 12 1 60 115 DESERT AIRE "EXPERT AIRE" MODEL LV08 MECHANICAL STORAGE 053 MODEL RC5S063C equipment, etc. furnish by mechanical - refer to both electrical and existing electrical apparatus as shown on one-line diagram and mechanical drawing for scope and work and additinal infor- Complete connection of HVAC/Plumbing motor(s), water heater(s), Fire alarm system is NIC. All fire alarm requirements shall be Complete feeder(s) installation as required for new and/or devices, new control devices, etc. for a complete system. including new panelboards, new conduits, new wires, new wiring Complete wiring system for new and reworked power as shown, contract. Electrical work shall include, but not be limited to, these major as indicated on drawings, as specified, and as necessary to complete the SCOPE: Furnish all materials and labor required to execute work 3. 4. 6. 5. Provide grounding and bonding facilities as required. Complete any electrical demolition required. mation. 1. ELECTRICAL SPECIFICATIONS and plans. A. items: CONDUCTOR SIZES AND TYPES: Use only copper wire, 600 volt insulation, stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. In sizes #1 and smaller, use types TW, THHN or THW. In sizes larger than #1, use THW or XHHW. Use type THHN for wires entering or passing MC cable permitted per local codes. through fluorescent lighting fixtures. CONDUIT AND WIRE: B. 13. A. and contractor shall have written approvals from building owner prior Core drilling and patching of existing building structure required for Provide operating, maintenance, and identification instruction manuals, if electrical work. Core drilling shall follow Building Standard procedures Applicable codes: National Electric Code (2008) PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- tions, examinations and fees or charges necessary for execution and and to the requirements of federal, state, or other city agencies local electrical code, pertinent NFPA publications, Conform to the prevailing edition and amendments thereto of the to start of any work. Test entire system to verify completion. REGULATIONS AND CODES: having jurisdiction. completion of electrical work. A. 7. 9. 8. 10. any. A. General Requirements 14. decora style. Finish per owner or architect. Convenience receptacles will be 20 amp, commercial grade ELECTRICAL DEVICES A. Support all electrical equipment independent of accessible ceilings as required by NEC. SUPPORT A. All mounting heights will conform to ADA guidelines. Typical receptacle B. heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise. At fire rated wall space electrical boxes on opposite sides of a wall shall be located no less than 24" horizontal distance. ELECTRICAL BOXES A. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. C. 2. 12. 11. designed/provided by others. ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) RECESSED OR SURFACE DOWNLIGHT WALL MOUNTED LIGHT FIXTURE RECESSED FLUOR. LIGHT FIXTURE SURFACE FLUOR. LIGHT FIXTURE Aa Aa FIXTURE DESIGNATIONS: UPPER CASE - FIXTURE TYPE LOWER CASE - SWITCH DESIGNATION SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP FLUORESCENT STRIP FIXTURE TRACK LIGHT AS NOTED OR SCHEDULED WALL WASHER POLE-MOUNTED FIXTURE POST (BOLLARD) FIXTURE CEILING OR WALL MOUNTED EXIT LIGHT EMERGENCY BATTERY LIGHTS DUPLEX RECEPTACLE @ 18" UNLESS NOTED DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED SPECIAL OUTLET AS NOTED FLUSH FLOOR DUPLEX RECEPTACLE DUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTED TELE-POWER POLE JUNCTION BOX IN FLOOR, CEILING OR IN WALL MULTI-OUTLET PLUG STRIP COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING TELEPHONE BACKBOARD CIRCUIT HOMERUN CONDUIT RUN BELOW FLOOR OR GRADE CONDUIT STUB-UP - CAP & MARK LIGHT SWITCH AT 48" UNLESS NOTED SUBSCRIPTS: 2 = 2-POLE SWITCH 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH K = KEY-OPERATED SWITCH TO = THERMAL OVERLOAD SWITCH P = SWITCH WITH PILOT LIGHT DIMMER SWITCH W/ WATTAGE MAGNETIC MOTOR STARTER DISCONNECT SWITCH TRANSFORMER GROUND PUSHBUTTON CONTROL STATION PHOTOELECTRIC CELL TIME SWITCH THERMOSTAT AT 60" UNLESS NOTED DIVISION 15 EQUIPMENT FOOD SERVICE EQUIPMENT PC TS T ABBREVIATIONS - ABOVE COUNTER AC AFF - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE AFG - ALUMINUM AL - DESIGNATION DESIG. - EMERGENCY EM - ELECTRIC WATER COOLER EWC - GROUND GND - GROUND FAULT INTERRUPTER GFI - NOT FUSED NF NIC - NOT IN CONTRACT NL - NIGHT LIGHT NTS - NOT TO SCALE UG - UNDERGROUND WP - WEATHER PROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE AFF OR AFG TELEVISION OUTLET DISTRIBUTION EQUIPMENT SYMBOLS DISCONNECT SWITCH FUSES CIRCUIT BREAKER CURRENT TRANSFORMER TRANSFORMER METER CU - COPPER EMP - ENERGY MANAGEMENT PANEL STEP LIGHT M = MOTION-OPERATED SWITCH POP-UP RECEPTACLE Scale Date Drawn By Checked By Project Number As Noted VAIL SPA CONDOMINIUMS bw wjm 1/21/2016 43808 710 W. LIONSHEAD CIRCLE No. Description Date 1 PROGRESS DRAWINGS 18 DEC 15 2 CD'S & PERMIT 21 JAN 16 "PEOPLE & PRODUCTS YOU CAN COUNT ON" PO BOX 810 825A CHAMBERS AVENUE EAGLE, CO 81631 800.543.9365 www.randhmechanical.com 3 CD'S & PERMIT 2 19 FEB 16 E2.01 x of x ELECTRICAL SCHEDULES AND SPECIFICATIONS 04/13/16