HomeMy WebLinkAboutB16-0029_P S 9_1478906275.pdf1
2
8
9
10
11
12
13
14
14
15
16
17
G
G
H
H
D
D
E
E
C
C
B-1
B-1
B
B
A
A RR
QQ
PP
NN
I
I
F
F
J
J
K
K
BB
AA
CC
DD
EE
HH
GG
FF
JJ
KK
LL
MM
32'-6 1/4" 32'-6 1/4" 32'-6 1/4" 32'-6 1/4"
UUU
XXX
UNIT
303
UNIT
301LL
UNIT
305LL
UNIT
309LL
UNIT
307UL
UNIT
313
UNIT
319
UNIT
321UL
UNIT
317LL
UNIT
315LL
UNIT
311LL
UNIT
302LL
UNIT
304
UNIT
308LL
UNIT
312
UNIT
310LL
UNIT
314LL
UNIT
316LL
UNIT
320LL
UNIT
322LL
UNIT
326LL
UNIT
324
UNIT
318
UNIT
306LL
EGRESS STAIR TO BE REMOVED.
ALL CONNECTIONS TO BUILDING TO BE PATCHED. UNIT 700
DOOR TO STAIR TO BE REPLACED WITH WINDOW.
MAINT. OFFICE
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING
STANDARD
UTILITY DOOR
REPLACE TRAFFIC COATING ON EXTERIOR
LANDINGS; REPAIR/REPAINT RAILINGS; COVER
GLULAM WITH COPPER AND COUNTER FLASH
UNDER TRAFFIC COATING
REPLACE TRAFFIC COATING ON EXTERIOR
LANDINGS; REPAIR/REPAINT RAILINGS; COVER
GLULAM WITH COPPER AND COUNTER FLASH
UNDER TRAFFIC COATING
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
1/27/2016 12:55:02 PM
A113
LEVEL 3 FINISH
PLAN
VAIL SPA
CONDOMINIUMS
MEW
MEW
01/21/2016
VSRP - 2016
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1 LEVEL 3 FINISH PLAN
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER
NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE
DEPT- 2 EXISTING BOXES ARE AT FDC LOCATIONS
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS
SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR
SIZE AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED
IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR
KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON
PLANS
12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY
CONSTRUCTED TO MATCH EXISTING, U.N.O
13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
14. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER STRUCTURAL DRAWINGS
15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATE OR MATCH EXISTING
16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR
TRANSITIONS
17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR
LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT
BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN
AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED
BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN.
CLEAR HEIGHT
18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBL
No. Description Date
1 PROGRESS/PRICIN
G
2 OCT
15
2 DRB REVIEW 12 OCT
15
3 PROGRESS/PRICIN
G 2
23 DEC
15
4 CDs/PERMIT 21 JAN
16
EMERGENCY EGRESS
Stair
Core 5
Stair
Core 3
Phase 1 closed
to public.
Maintain paths
of egress for
construction
personnel
CLOSED TO PUBLIC
Construction Logistic & Public Safety Plan: 6/01/16 - 6/14/16
04/13/16