HomeMy WebLinkAboutB16-0031_A10.0_1478903318.pdfTELEPHONE/
DATA
GFI
WP
220
TV
FAN
3
D
DUPLEX OUTLET
SWITCHED OUTLET (ONE SIDE ONLY)
GROUND FAULT INTERRUPT OUTLET
WATER PROOF GFI OUTLET
220 OUTLET
FLOOR MOUNTED DUPLEX
TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V
2 CAT V TELEPHONE
RECESSED DIRECTIONAL DOWN LIGHT
FLAT OR SLOPED CEILING
RECESSED 4-LIGHT MULTIPLE
DIRECTIONAL DOWN LIGHT
SURFACE MOUNTED FIXTURE @ WALL
WALL MOUNTED UP LIGHT FIXTURE
WALL MOUNTED STEP LIGHT FIXTURE
SURFACE MOUNTED FLORESCENT
SURFACE MOUNTED ON CEILING
LED LIGHTING UNDER CABINET LIGHTING
SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD
JUNCTION BOX
EXHAUST FAN
SWITCH
3-WAY SWITCH / 4-WAY SWITCH
DIMMER SWITCH (MAY BE SHOWN AS 3-WAY)
MONOPOINT
J-BOX
MOTORIZED SHADE W/ BUILT-IN POCKET
TRU- FIG DUPLEX OUTLET
TF
DUPLEX OUTLET W/ (2) USB PORTS
USB
K
K1
LIGHTING CONTROL KEY PAD
SMART SWITCH CONNECTED TO
LIGHTING CONTROL
GENERAL NOTES:
1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF
ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL,
STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
2. OUTLETS TO BE LOCATED HORIZONTAL AND CENTERED IN THE BASE BOARD, AND SWITCHES 42" ABOVE
FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT
THE ARCHITECT.
3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE ALARM
SYSTEM AS REQ'D PER T.O.V.
4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO
ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE.
5. PROVIDE GFI OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
6. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE PLANS AND
INTERIOR DOCUMENTS
7. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE
DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM.
8. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY
LOCATION & HEIGHT WITH OWNER
9. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS.
10. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC.
11. COORDINATE OUTLET W/ FURNITURE PLANS PER OWNER
12. COORDINATE KITCHEN POWER STRIP W/ OWNER AND PER SPEC - POWER STRIP TO BE LOCATED ON
UNDERSIDE OF CABINET AT JUNCTURE WITH WALL
13. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS
14. PROVIDE LIGHTING CONTROL SYSTEM AND LOW VOLTAGE CONTROL SYSTEM PER OWNER'S DIRECTION.
15. SEE WINDOW SCHEDULE FOR ALL WINDOWS THAT HAVE LUTRON MOTORIZED SHADE. ALL WINDOW HEADERS
TO BE FRAMED WITH 5" TALL X 4 3/4" DEEP POCKET. SEE DETAILS ON A6.5.
16. PROVIDE TYPE L2 - FLEXIBLE LED LIGHT STRIP @ BATHROOM VANITY TOE KICKS. TO BE SWITCHED W/ VANITY
SCONCES.
17. PROVIDE PRICING OPTION FOR ELECTRICAL TRANSFORMER @ ALL HALO CAN LIGHTS.
18. PROVIDE DEDUCTIVE PRICING OF HIGH QUALITY HALOGEN MR16 LAMP INSTEAD OF LED LIGHT SPECIFIED.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
3/24/2016
9:05:10 AM
A10.0
ELECTRICAL
SCHEDULE
AND NOTES
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
ELECTRICAL LEGEND
Lighting Fixture Schedule
Type Mark Type Manufacturer Model Type Comments Count
25
A FLAT CEILING RECESSED CAN -
EFFICACY
HALO H36LVICAT - 3004WHH OR
3009WHWB
3004WHH - WHITE W/HAZE REFLECTOR @ DRYWALL CEILING.
3009WHWB - WHITE W/WHITE BAFFLE @ DRYWALL CEILING. WALL
WASHER LOCATIONS - 3" LOW VOLTAGE UNIVERSAL IC HOUSING -
PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP
97
A2 FLAT CEILING MOISTURE RESISTANT
RECESSED CAN
HALO H36LVICAT - 3007WHC WHITE W/ SPECULAR CLEAR REFLECTOR - 3" LOW VOLTAGE UNIVERSAL
IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K
LAMP
7
A3 FLAT CEILING RECESSED CAN - LED
LIGHT
LIGHTOLIER 1050RNDLCDW -
1050LRN0927
5" LED RECESSED IC LOWNLIGHT, LENSED, ROUND TRIM, IC AND WET
RATED, CLEAR DIFFUSE WHITE FLANGE, ELECTRIC BALLAST - PROVIDE
SORAA VIVID2 LED MR16 35 DEGREE FL, 2700K LAMP
14
A5 FLAT CEILING RECESSED CAN - WINE
ROOM
2
B SLOPED CEILING RECESSED CAN -
HIGH EFFICACY
HALO H36LVICAT - 3004TBZ OR
3009TBZBB
3004TBZ - TUSCAN BRONZE W/ TUSCAN BRONZE REFLECTOR @ WOOD
CEILING. 3009TBZBB - TUSCAN BRONZE W/ BLACK BAFFLE @ WOOD
CELING WALL WASHER. 3" LOW VOLTAGE UNIVERSAL IC HOUSING -
PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP
61
B2 SLOPED CEILING MOISTURE
RESISTANT RECESSED CAN
HALO H36LVICAT - 3007WHC WHITE W/ SPECULAR CLEAR REFLECTOR - 3" LOW VOLTAGE UNIVERSAL
IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K
LAMP
2
B3 SLOPED CEILING RECESSED CAN -
LED LIGHT
3
C 7
D1 MASTER BATHROOM SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/
INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE
2
D2 BATHROOM #2 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/
INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE
3
D3 BATHROOM #3 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/
INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE
3
D5 BATHROOM #5 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/
INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE
5
D6 MAIN LEVEL POWDER ROOM
SCONCE
FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/
INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE
2
D9 BUNK BED READING LIGHT SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 2'- 10" AND 5'-10" AFF.
VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW
VOLTAGE
6
E WALL MOUNTED EXTERIOR SCONCE HEVI HL-374-BZ, MOUNTED @
6'-0" ABOVE FINISHED
FLOOR
PAR-20 BRONZE POWDER COAT FINISH (BZ) 2
F WALL MOUNTED CLOSET LIGHT -
HIGH EFFICACY
CREATIVE ILLUMINATIONS UC-132EL LINEAR UNDER CABINET LIGHT, 4' NOMINAL LENGTH ELECTRONIC
BALAST, WHITE METAL HOUSING, ADJUST LENGTH AS REQ'D.
MOUNTED ABOVE CLOSET DOOR WITH JAMB SWITCH
5
H 1X4 FLORESCENT - HIGH EFFICACY CREATIVE ILLUMINATIONS 102-32 (2) F32T8 3000K 80+
CRI LAMPS
LINEAR INDUSTRIES STRIPLIGHT, NOMINAL 4' ELECTRIC BALLAST.
SURFACE MOUNTED @ MECH. AND GARAGE TYPE LOCATIONS.
6
H2 48" LENSED FLORESCENT SURFACE
MOUNT
PRUDENTIAL LIGHTING S1-2T5-04'-WA-YGW-120-S
UR-X3
WHITE ACRYLIC LENS. PHILIPS ALTO: (2) 28W T5, 3000K 80+ CRI 5
L UNDER CABINET LED ROPE LIGHT-
HIGH EFFICACY
PARADIGM LED LB36 - LENGTH - SSAP -
100
COORDINATE TRANSFORMER AND TRANSFORMER LOCATION,
EXTRUDED HOUSING, 36 LED/FOOT, 30W DIMMABLE POWER SUPPLY
5/8" DEEP X 1.2" WIDE, AVAILABLE 6", 1', 2', 3', 4' LENGTHS WITH
COUPLERS.
21
L2 LED ROPE LIGHT- HIGH EFFICACY 8
M MONOPOINT SURFACE MOUNTED -
HIGH EFFICACY
HEVI LITE HL-384-BZ INTEGRAL LOW VOLTAGE TRANSFORMER, BRONZE FINISH - PROVIDE
SORAA VIVID 2 LED MR16 35 BULB
12
P PENDANT LIGHT TECH LIGHTING 700-FJ-CON-W-S LOW VOLTAGE CONE PENDANT, WHITE FINISH 2
Q EXTERIOR STEP LIGHT- HIGH
EFFICACY
WAC WL-LED200TR-C-WT TRIMLESS, WALL MOUNTED - CENTER OF BOX @ 1' - 6" AFF 32
Q2 INTERIOR STEP LIGHT - HIGH
EFFICACY
WAC WL-LED200-C-BZ WALL MOUNTED - CENTER OF BOX @ 1' - 6" AFF 8
S LIGHTED MIRROR- HIGH EFFICACY SCOTT LAMP 9228 24X40, (2) 14 W AND (2) 21 WATT T-5 LAMPS,AMOUNT OUTLET @ 5'-3" AFF
@ CENTER OF MIRROR
8
U IN-FLOOR UP LIGHT WINSCAPE LAURELL LA-0-12V-L2-BRS-FO-SH6-
PC-MOD, PROVIDE W/
THERMAL PROTECTOR
VERIFY FINISH WITH INTERIOR DESIGNER, PROVIDE CONCRETE POUR
COLLAR, HONEY COMB LOUVER LINEAR LENSE, PROVIDE SORAA VIVID
2 LED MR16 35 DEGREE FL, 2700K LAMP
15
Grand total: 363
LIGHTING EFFICACY CALCULATIONS:
PER SECTION R404.1 IN THE 2015 IECC A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS, WITH THE
EXCEPTION THAT LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO UTILIZE HIGH EFFICACY LAMPS.
506 TOTAL FIXTURES ARE PROPOSED WITH 421 BEING LOW VOLTAGE, PER THE EXCEPTION ABOVE 85 FIXTURES WILL BE USED IN THE CALCULATION. 2,351 LAMPS ARE PROPOSED IN
PROJECT. 2,327 LAMPS ARE HIGH EFFICACY.
2327/2351=.989
98% OF THE LAMPS IN THE HOUSE ARE HIGH EFFICACY WHICH EXCEEDS THE REQUIREMENT OF 75% IN R404.1 IN THE 2015 IECC.
LIGHTING SUBSTITUTION:
- CONTRACTOR MAY SPECIFY A 3" OR 4" NORA LIGHTING PRODUCT TO SUBSTITUTE FOR THE HALO BRAND RECESSED CAN LIGHTS.
No. Revision Date
Revision
Description
1 MARCH 22,
2016
BUILDING
PERMIT
COMMENTS
04/11/16