Loading...
HomeMy WebLinkAboutB16-0031_A10.0_1480363226.pdfTELEPHONE/ DATA GFI WP 220 TV FAN 3 D DUPLEX OUTLET SWITCHED OUTLET (ONE SIDE ONLY) GROUND FAULT INTERRUPT OUTLET WATER PROOF GFI OUTLET 220 OUTLET FLOOR MOUNTED DUPLEX TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V 2 CAT V TELEPHONE RECESSED DIRECTIONAL DOWN LIGHT FLAT OR SLOPED CEILING SURFACE MOUNTED FIXTURE @ WALL WALL MOUNTED UP LIGHT FIXTURE WALL MOUNTED STEP LIGHT FIXTURE SURFACE MOUNTED FLORESCENT SURFACE MOUNTED ON CEILING LED LIGHTING UNDER CABINET LIGHTING SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD JUNCTION BOX EXHAUST FAN SWITCH 3-WAY SWITCH / 4-WAY SWITCH DIMMER SWITCH (MAY BE SHOWN AS 3-WAY) MONOPOINT J-BOX MOTORIZED SHADE W/ BUILT-IN POCKET TRU- FIG DUPLEX OUTLET TF DUPLEX OUTLET W/ (2) USB PORTS USB K K1 LIGHTING CONTROL KEY PAD SMART SWITCH CONNECTED TO LIGHTING CONTROL GENERAL NOTES: 1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES. 2. OUTLETS TO BE LOCATED HORIZONTAL AND CENTERED IN THE BASE BOARD, AND SWITCHES 42" ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT THE ARCHITECT. 3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM AS REQ'D PER T.O.V. 4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE. 5. PROVIDE GFI OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS. 6. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE PLANS AND INTERIOR DOCUMENTS 7. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM. 8. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY LOCATION & HEIGHT WITH OWNER 9. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS. 10. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC. 11. COORDINATE OUTLET W/ FURNITURE PLANS PER OWNER 12. COORDINATE KITCHEN POWER STRIP W/ OWNER AND PER SPEC - POWER STRIP TO BE LOCATED ON UNDERSIDE OF CABINET AT JUNCTURE WITH WALL 13. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS 14. PROVIDE LIGHTING CONTROL SYSTEM AND LOW VOLTAGE CONTROL SYSTEM PER OWNER'S DIRECTION. 15. SEE WINDOW SCHEDULE FOR ALL WINDOWS THAT HAVE LUTRON MOTORIZED SHADE. ALL WINDOW HEADERS TO BE FRAMED WITH 5" TALL X 4 3/4" DEEP POCKET. SEE DETAILS ON A6.5. 16. PROVIDE TYPE L2 - FLEXIBLE LED LIGHT STRIP @ BATHROOM VANITY TOE KICKS. TO BE SWITCHED W/ VANITY SCONCES. 17. PROVIDE PRICING OPTION FOR ELECTRICAL TRANSFORMER @ ALL HALO CAN LIGHTS. 18. PROVIDE DEDUCTIVE PRICING OF HIGH QUALITY HALOGEN MR16 LAMP INSTEAD OF LED LIGHT SPECIFIED. 19. PROVIDE SINGLE BUTTON LUTRON KEYPAD @ ALL BEDROOMS FOR MOTORIZED SHADE 20. ALL EXTERIOR LIGHTING TO BE ON LIGHTING CONTROL SYSTEM. PROVIDE KEYPAD TO OPERATE EXTERIOR LIGHTING PER CODE Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/16/2016 10:40:41 AM A10.0 ELECTRICAL SCHEDULE AND NOTES CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/4" = 1'-0" ELECTRICAL LEGEND Lighting Fixture Schedule Type Mark Type Manufacturer Model Type Comments Count 13 A FLAT CEILING RECESSED CAN - EFFICACY NORA LIGHT W/ HALO TRIM NLIC-401 - 3004WHH OR 3009WHWB 3004WHH - WHITE W/HAZE REFLECTOR @ DRYWALL CEILING. 3009WHWB - WHITE W/WHITE BAFFLE @ DRYWALL CEILING. WALL WASHER LOCATIONS - 3" LOW VOLTAGE UNIVERSAL IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP 98 A2 FLAT CEILING MOISTURE RESISTANT RECESSED CAN NORA LIGHT W/ HALO TRIM NLIC-401 - 3007WHC WHITE W/ SPECULAR CLEAR REFLECTOR - 3" LOW VOLTAGE UNIVERSAL IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP 7 A3 FLAT CEILING RECESSED CAN - LED LIGHT LIGHTOLIER 1050RNDLCDW - 1050LRN0927 5" LED RECESSED IC LOWNLIGHT, LENSED, ROUND TRIM, IC AND WET RATED, CLEAR DIFFUSE WHITE FLANGE, ELECTRIC BALLAST - PROVIDE SORAA VIVID2 LED MR16 35 DEGREE FL, 2700K LAMP 14 A5 FLAT CEILING RECESSED CAN - WINE ROOM 2 B SLOPED CEILING RECESSED CAN - HIGH EFFICACY NORA LIGHT W/ HALO TRIM NLIC-401 - 3004TBZ OR 3009TBZBB 3004TBZ - TUSCAN BRONZE W/ TUSCAN BRONZE REFLECTOR @ WOOD CEILING. 3009TBZBB - TUSCAN BRONZE W/ BLACK BAFFLE @ WOOD CELING WALL WASHER. 3" LOW VOLTAGE UNIVERSAL IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP 61 B2 SLOPED CEILING MOISTURE RESISTANT RECESSED CAN NORA LIGHT W/ HALO TRIM NLIC-401 - 3007WHC WHITE W/ SPECULAR CLEAR REFLECTOR - 3" LOW VOLTAGE UNIVERSAL IC HOUSING - PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP 2 B3 SLOPED CEILING RECESSED CAN - LED LIGHT 5" LED RECESSED IC LOWNLIGHT, LENSED, ROUND TRIM, IC AND WET RATED, CLEAR DIFFUSE WHITE FLANGE, ELECTRIC BALLAST - PROVIDE SORAA VIVID2 LED MR16 35 DEGREE FL, 2700K LAMP 3 C UP-LIGHT SCONCE BELFER 6230 VARIAL 100 W HALOGEN BULB. WHITE @ DRYWALL, BLACK @ STEEL BEAMS. 7 D1 MASTER BATHROOM SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE 2 D2 BATHROOM #2 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE 3 D3 BATHROOM #3 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE 3 D5 BATHROOM #5 SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-6" AFF. VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE 2 D7 BEDROOM #5 SCONCE WALL MOUNTED SCONCE - CENTER OF BOX @ 5'-0" AFF 2 D9 BUNK BED READING LIGHT SCONCE FIXTURE TBD BY INTERIOR DESIGNER WALL MOUNTED SCONCE - CENTER OF BOX @ 2'- 10" AND 5'-10" AFF. VERIFY W/ INTERIOR DESIGNER - COORDINATE LINE VOLTAGE OR LOW VOLTAGE 6 E WALL MOUNTED EXTERIOR SCONCE HEVI HL-374-BZ, MOUNTED @ 6'-0" ABOVE FINISHED FLOOR PAR-20 BRONZE POWDER COAT FINISH (BZ) 2 F WALL MOUNTED CLOSET LIGHT - HIGH EFFICACY CREATIVE ILLUMINATIONS UC-132EL LINEAR UNDER CABINET LIGHT, 4' NOMINAL LENGTH ELECTRONIC BALAST, WHITE METAL HOUSING, ADJUST LENGTH AS REQ'D. MOUNTED ABOVE CLOSET DOOR WITH JAMB SWITCH 5 H 1X4 FLORESCENT - HIGH EFFICACY CREATIVE ILLUMINATIONS 102-32 (2) F32T8 3000K 80+ CRI LAMPS LINEAR INDUSTRIES STRIPLIGHT, NOMINAL 4' ELECTRIC BALLAST. SURFACE MOUNTED @ MECH. AND GARAGE TYPE LOCATIONS. 6 H2 48" LENSED FLORESCENT SURFACE MOUNT PRUDENTIAL LIGHTING S1-2T5-04'-WA-YGW-120-S UR-X3 WHITE ACRYLIC LENS. PHILIPS ALTO: (2) 28W T5, 3000K 80+ CRI 5 J-BOX J-BOX CEILING FAN RATED 16 L UNDER CABINET LED ROPE LIGHT- HIGH EFFICACY PARADIGM LED LB36 - LENGTH - SSAP - 100 COORDINATE TRANSFORMER AND TRANSFORMER LOCATION, EXTRUDED HOUSING, 36 LED/FOOT, 30W DIMMABLE POWER SUPPLY 5/8" DEEP X 1.2" WIDE, AVAILABLE 6", 1', 2', 3', 4' LENGTHS WITH COUPLERS. 21 L2 LED ROPE LIGHT- HIGH EFFICACY 8 M MONOPOINT SURFACE MOUNTED - HIGH EFFICACY HEVI LITE HL-384-BZ INTEGRAL LOW VOLTAGE TRANSFORMER, BRONZE FINISH - PROVIDE SORAA VIVID 2 LED MR16 35 BULB 12 P PENDANT LIGHT TECH LIGHTING 700-FJ-CON-W-S LOW VOLTAGE CONE PENDANT, WHITE FINISH 2 Q EXTERIOR STEP LIGHT- HIGH EFFICACY WAC WL-LED200-C-BZ WALL MOUNTED - CENTER OF BOX @ 1' - 6" AFF 33 Q2 INTERIOR STEP LIGHT - HIGH EFFICACY WAC WL-LED200TR-C-WT TRIMLESS, WALL MOUNTED - CENTER OF BOX @ 1' - 6" AFF 8 U IN-FLOOR UP LIGHT WINSCAPE LAURELL LA-0-12V-L2-BRS-FO-SH6- PC-MOD, PROVIDE W/ THERMAL PROTECTOR VERIFY FINISH WITH INTERIOR DESIGNER, PROVIDE CONCRETE POUR COLLAR, HONEY COMB LOUVER LINEAR LENSE, PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP 25 Grand total: 368 LIGHTING EFFICACY CALCULATIONS: PER SECTION R404.1 IN THE 2015 IECC A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS, WITH THE EXCEPTION THAT LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO UTILIZE HIGH EFFICACY LAMPS. 506 TOTAL FIXTURES ARE PROPOSED WITH 421 BEING LOW VOLTAGE, PER THE EXCEPTION ABOVE 85 FIXTURES WILL BE USED IN THE CALCULATION. 2,351 LAMPS ARE PROPOSED IN PROJECT. 2,327 LAMPS ARE HIGH EFFICACY. 2327/2351=.989 98% OF THE LAMPS IN THE HOUSE ARE HIGH EFFICACY WHICH EXCEEDS THE REQUIREMENT OF 75% IN R404.1 IN THE 2015 IECC. LIGHTING SUBSTITUTION: - CONTRACTOR MAY SPECIFY A 3" OR 4" NORA LIGHTING PRODUCT TO SUBSTITUTE FOR THE HALO BRAND RECESSED CAN LIGHTS. - UPATED ELECTRICAL LEGEND - CAN LIGHT SPECIFICATION UPDATED - J-BOX COUNT UPDATED No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16