HomeMy WebLinkAboutB16-0031_A10.3_1478903137.pdfA4.3
A4.4
1
1
A4.1
A4.2
1
1
A4.5
2
A4.5
3
1
A5.5
1
A5.7
1
A5.6
2
A5.5
A4.5
1
1
A5.1
4
A5.5
2
A5.7
1
A5.2
1
A5.3
1
A5.4 2
A5.4
3
A5.5
STAIRS
213
OFFICE
216
CLOSET
217
W.C.
219
BATHROOM #2
218
BEDROOM #2
215
BRIDGE
214
BEDROOM #4
207
OFFICE
212
W.C.
211
SHOWER
210
BATH #4
209
CLOSET
208
BEDROOM #3
201
BATH #3
204 CLOSET
202
W.C.
205
1
A5.8
1
A5.9
1
1
2
2
3
3
4
4
5
5 6
6 7
7 8
8 9
9
10
10 11
11 12
12
A
A
B
B
C
C
D
D
E
E
F
F
H
H
K
K
L
L
M
M
G1
G4
GD
GD
GC
GC
GA
GA
GB
GB
I I
J J
G5
G2
2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4"
82' - 2"
17' - 4 1/2"
6' - 7 1/2"
5' - 9"
29' - 9"
1' - 9 1/2"8' - 6 1/2"13' - 2"
23' - 6"
1' - 2"
1' - 0"1' - 4"10" 12' - 3" 3' - 6" 1' - 7" 7' - 6 9/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 8"
G3
1
A5.10
Q
Q Q
Q
Q
L2
CLG
FAN
B
B
B
B
B
B2
D2
D2
D2
D2
A A
B
B
B B
B B
B B
CLG
FAN
B
B
B
B
B
B
B2
B
B
B
B
FAN
FAN
FAN
A
A
FAN
A
A
A
A
B3
B3
B
B
D9
L
D3 D3 D3
FAN
B3
B
D9
A3
A3
A2
B
B B
B
A2
L
CLG
FAN
A
A
L
L2
L2
FAN
6" / 12" 6" / 12"
6" / 12" 6" / 12"
2 1/2" / 12"
6" / 12"
6" / 12"
2 1/2" / 12"
6" / 12"6" / 12"
2 1/2" / 12"
2 1/2" / 12"
4" / 12" 4" / 12"
4" / 12"
4" / 12"
32' - 11 1/4"
10X WOOD TRIM
10X WOOD TRIM
10X14 RIDGE BEAM
8X8 RAFTER
10X14 RIDGE BEAM
8X8 RAFTER
READING SCONCE
AND ELECTRICAL
OUTLET @ UPPER
AND LOWER BUNK
READING
SCONCE AND
ELECTRICAL
OUTLET @
UPPER AND
LOWER BUNK
4
A8.1
10
A8.1
GFI
GFI
CNTR
CABINET
CNTR
CABINET
GFI
GFI
GFI CNTR
GFI CNTR
220
CNTR
CABI
NET
2 1/2" / 12"
TV
2 1/2" / 12"
MOTORIZED SHADES @ WINDOWS TRANSOM
GAS
4
A8.1 GFI
GFI
TV
SHOWER
203
PROVIDE ACCESS PANEL FOR STEAM GENERATOR
BENCH
1/8" / 12"
A
L
L
UNDER CABINET
LED LIGHTING
FLOOR LAMPS
1/8" / 12"
4' - 0"
4' - 0"
4' - 6 3/16" 4' - 6 3/16" 4' - 6 3/16"
K K
K
A
A2
A2
8X8 RAFTER
2
A6.6
L
L
4
A4.5
B.O. GWB @ 9' - 6" AFF
B.O. GWB @ 9' - 6" AFF
B.O. GWB @ 9' - 6" AFF
B.O. GWB @ 9' - 6" AFF
B.O. GWB @ 10' - 2"
10
A8.1
24" X 24"
ACCESS
HATCH FOR
BEDROOM #3
FANCOIL. RE:
MECH. PLANS
A
A TELEPHONE/DATA
TELEPHO
NE/
DATA
TELEPHONE/
DATA
TELEPHONE/
DATA
TELEPHONE/DATA
TV
TV
A
G
G
A4.3 3
Q
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
3/2/2016
5:16:24 PM
A10.3
UPPER
LEVEL RCP
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1/4" = 1'-0" 1
UPPER LEVEL REFLECTED CEILING
PLAN
GENERAL NOTES:
1) EXTERIOR LIGHTING:
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 14 LIGHTS ARE ALLOWED. 14 EXTERIOR LIGHTS MORE THAN 18"
ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES.
2) (21) MOTORIZED SHADES SHOWN ON THIS LEVEL.
3) PROVIDE SHADE POCKETS @ ALL WINDOWS U.N.O.
4) PREWIRE FOR MOTORIZED SHADES @ ALL WINDOWS.
No. Revision Date
Revision
Description
04/11/16