HomeMy WebLinkAboutB16-0031_A5.4_1478903178.pdfMAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" 1 A5.7 1 A5.6 2 A5.7 B.O. STRUCT. @ 9' - 1 3/8" AFF B.O. CEILING @ 9' - 0" AFF LINE OF EXISTING GRADE BEDROOM #4 207 BEDROOM #3 201 KITCHEN 108 POWDER 112 MUDROOM 113 WET STORAGE 004 FAMILY ROOM 001 4' - 0" 1 A5.8 B.O. CEILING @ 10' - 2" AFF A B C D E F H K L M I J 1' - 2"1' - 0"1' - 4" 10" 12' - 3" 10" 2' - 8" 1' - 7" 7' - 6 9/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 8" A6.4 3 A6.5 3 T.O. CONC 3' - 7 1/4" A6.9 5 T.O. STL. BEAM @ 22' - 0 3/4" 12' - 0" 10' - 5" 1 A5.10 B.O. STRUCT. TO CONC. 7' - 0 1/8" B.O. CELING STRUCT. @ 7' - 6 5/8" AFF B.O. CEILING @ 9' - 6" AFF 1' - 8 3/8" B.O. CEILING @ 9' - 6" AFF 1/8" / 12" 1/8" / 12" B.O. BEAM @ 9' - 9 5/8" AFF T.O. MAT SLAB @ 2 1/2" W12X26 T.O. STL. BEAM @ 23' - 6 3/4" T.O. CONC. TO B.O. STRUCT. 9' - 2 1/8" B.O. BEAM @ 9' - 9 5/8" AFF B.O. SOFFIT @ 9' - 0" AFF W12X30 5 1/2" LVL FLOOR FRAMING RE: STRUCT. FAN COIL FOR BEDROOM #3 A/C LOCATED ABOVE LAUNDRY ROOM CEILING. RE: RCP FOR ACCESS HATCH LOCATION AND RE: MECH PLANS. T.O. CONC. @ 11' - 6" T.O. CONC. LEDGE @ 10' - 8 3/4" 7' - 6" G 12" X 12" AIR SUPPLY DUCT. RE: MECH PLANS. 2' - 1 1/4" MAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" 2 A5.5 3 A5.5 T.O. PLATE @ 9' - 8" T.O. PLATE @ 11' - 0" LINE OF EXISTING GRADE OFFICE 212 GARAGE 114 BEDROOM #4 207 4' - 0" 2 1/2" / 12" 6" / 12" 11.2° A6.7 1 GD GC GA GB 5/8" TYPE X GYP. BOARD 13' - 2" 8' - 6 1/2" 1' - 9 1/2" 23' - 6" B.O. CEILING @ 10' - 0" ABOVE CONC. T.O. MAT SLAB @ 2' - 1 1/4" T.O. CONC. @ 10' - 1 1/8" A6.10 1 A6.1 2 1' - 1" A6.2 1 T.O. STRUCTURE @ 39' - 2 1/8" 0' - 7 3/8" B.O. HEADER @ 8' - 6 3/8" 7 1/2" A6.11 3 2' - 0 3/16" 4 A4.5 W18X35 T.O. STL. BEAM @ 22' - 6 7/8" T.O. STL. BEAM @ 37' - 9 3/8" W14X22 B.O. STRUCT. @ 12' - 7 1/4" ABOVE CONC. T.O. TOPPING SLAB @ 2' - 3 1/4" CONC. PAVER DRIVEWAY 1/4" / 12" T.O. CONC. LEDGE @ 9' - 4" T.O. CONC. @ 10' - 5 7/8" T.O. CONC. @ 10' - 8" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 3/2/2016 5:11:40 PM A5.4 BUILDING SECTIONS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/4" = 1'-0" 1 Section 4 1/4" = 1'-0" 2 Section 5 No. Revision Date Revision Description 04/11/16