Loading...
HomeMy WebLinkAboutB16-0031_A5.7_1478903183.pdfMAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" T.O. PLATE @ 10' - 0" 1 A5.1 BEDROOM #2 215 MASTER BEDROOM 105 LIVING ROOM 106 DINING ROOM 107 KITCHEN 108 HEARTH ROOM 111 BEDROOM #3 201 CLOSET 202 FAMILY ROOM 001 MECHANICAL ROOM 008 W.C. 010 BATH #5 011 4 A5.5 1 A5.2 1 A5.3 1 A5.4 LINE OF EXISTING GRADE 6" / 1 2" 6" / 12" 6 " / 1 2 " A6.9 1 A6.8 1 1 A5.9 T.O. PLATE @ 10' - 6 3/4" T.O. PLATE @ 9' - 9" T.O. PLATE @ 9' - 9" A6.4 4 1 2 3 4 5 6 7 8 9 10 11 12 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" A7.1 6 2' - 6" A6.11 3 B.O. STRUCT. @ 9' - 2 1/8" AFF SIM KITCHEN HOOD TO BE VENTED OUT CHIMNEY T.O. MAT SLAB @ 2 1/2" 2 1/2" / 12" B.O. HEADER @ 10' - 4 7/8" B.O. HEADER @ 8' - 8 7/8" 44' - 6 3/4" T.O. STL. BEAM @ 22' - 0 3/4" 10' - 5" 12' - 0" BATH #5 SHOWER 011B 2' - 1" B.O. STRUCT. @ 10' - 9 1/8" AFF 1/8" / 12" T.O. TOPPING SLAB @ 8 1/2" T.O. TOPPING SLAB @ 6 5/8" T.O. PLATE @ 11' - 9" T.O. STL. BEAM @ 38' - 0 5/8" W16X36 T.O. STL. BEAM @ 38' - 0" W14X22 W21X44 T.O. STL. BEAM @ 23' - 6 3/4" W10X19 T.O. STL. BEAM @ 23' - 6 3/4" W18X65 B.O. CEILING @ 8' - 3" AFF B.O. STRUCT. @ 10' - 9 1/8" AFF T.O. STL. BEAM @ 11' - 6" T.O. CONC. TO B.O. STRUCT. 9' - 2 1/8" 8" 10 A8.1 A6.11 3 W12X30 T.O. MAT SLAB @ 2 1/2" 1/8" / 12" OVER FRAMING ROOF CRICKETE RE: ROOF PLAN PRE-FABRICATED STL. SPIRAL STAIRCASE B.O. BEAM @ 9' - 11 5/8" AFF SEE SHEET A7.3 FOR LIVING ROOM FIREPLACE INFORMATION ROOF CRICKET RE: ROOF PLAN SIM NON-COMBUSTIBLE FLOOR STRUCTURE BELOW FIREPLACE RE: FIREPLACE SHEET AND STRUCT. 4" ROUND TUBE STL. COLUMN TO SUPPORT STAIR AND DECK STRUCT. RE: STRUCT. FRESH AIR IN-TAKE DUCT.RE: MECH. PLANS 5 1/2" LVL FLOOR STRUCT. OVER BATH #5. RE: STRUCT. A6.5 4 A6.8 5 1' - 0" T.O. CONC. SLAB @ 11' - 6 1/4" T.O. CONC. LEDGE @ 10' - 11 1/4" T.O. STL. BEAM @ 11' - 2 1/4" T.O. STL. BEAM @ 10' - 8 1/8" 9 1/4" 1' - 1" A7.3 4 MAINTAIN 1' CLEAR FROM B.O. AIR IN-TAKE LOUVER TO T.O. GRADE. RE: MECH. 12" MIN. SEE SHEET A7.1 FOR HEARTH ROOM FIREPLACE INFORMATION 2' - 10 1/2" MAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" 4 A5.5 1 A5.4 Q T.O. PLATE @ 10' - 2 1/2" T.O. PLATE @ 11' - 9 1/8" 2 1/2" / 12" 8 9 10 11 12 3' - 4" 14' - 3" 9' - 3" 2' - 0" 28' - 10" A7.2 3 Q B.O. HEADER @ 8' - 8 1/8" 3' - 0" 12' - 0" BUILDING HEIGHT LIMIT 33' ABOVE EXISTING GRADE @ ROOF RIDGE EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT *4A T.O. STRUCTURE @ 39' - 4 3/4" MOTORIZED SHADE POCKETS INDICATED WITH DASHED LINE AND HATCH RE: RCP 32' - 9 3/4" EXISTING GRADE @ 6' - 7" 2' - 6" 28 28 4 A8.1 7 A6.8 4 A8.1 10 A8.1 7 A8.1 28 10 12 9 15 24 T.O. CONC. @ 13' - 9" B.O. HEADER @ 10' - 4 1/8" 6 A8.1 T.O. DOOR HEADER @ 8' - 8 1/8" 3 A8.1 6" / 12" 6" / 12" Q Q Q B.O. HEADER @ 8' - 8 1/8" B.O. HEADER @ 10' - 4 1/8" 5 A8.1 11 A8.1 39 112 38 112 40 112 43 112 42 112 39 112 38 112 37 111 35 111 34 111 36 111 62 207 62 207 61 207 61 207 66 209 65 209 64 209 67 209 622 110B 8 A6.9 9" 4 A6.8 T.O. CONC. LEDGE @ 11' - 8" 6 A6.5 3 A6.5 2 A6.3 SEE SHEET A7.2 FOR OUTDOOR LIVING ROOM FIREPLACE INFORMATION Q MATERIALS 1. STANDING SEAM METAL ROOF - COPPER RE: SPEC 2. SYNTHETIC SHAKE ROOF RE: SPEC 3. 6X10 WOOD RAFTERS. RE: STRUCT 4. 8X10 RAFTERS RE: STRUCT 5. 2X10 FASCIA 6. 10X14 WOOD OUTLOOK BEAM RE: STRUCT. 7. 8X12 WOOD EAVE BEAM 8. COPPER SHINGLE SIDING RE: SPEC 9. DRY STACKED STONE VENEER RE: SPEC & FINISH SCHEDULE 10. RECLAIMED VERTICAL WOOD SHIP LAP SIDING W/ NO REVEAL BETWEEN BOARDS RE: SPEC & FINISH SCHEDULE 11. HORIZONTAL SHIP LAP SIDING W/ 1/4" REVEAL RE: SPEC & FINISH SCHEDULE 12. 3X3 WOOD TRIM 13. LIFT AND SLIDE DOOR SYSTEM 14. STEEL C-CHANNEL WINDOW HEADER. RE: STRUCT 15. PFSM CLAD PANEL SIDING PAINTED TO MATCH WINDOWS 16. CUT STONE CAP W/ 10 PERCENT MIN. SLOPE AT TOP TO SHED WATER 17. STEEL BEAM. RE: STRUCT 18. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND LAG BOLTED TO STEEL BEAM 19. TYPICAL STEEL HANDRAIL PAINTED CUSTOM BLUE/BLACK COLOR 20. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT. PIPE UNDERGROUND TO DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND PROVIDE POWER FOR HEAT TAPE. 21. 10X10 WOOD DECK COLUMN OVER STEEL CAP AND 4X4 HSS COLUMN BASE 22. CUSTOM STEEL CHIMNEY CAP 23. 4" THICK STONE CHIMNEY CAP 24. WOOD BEAM 25. WOOD OUTLOOK BEAM 26. CURVED GLULAM BEAM RE: STRUCT 27. STEEL SPIRAL STAIRCASE 28. PROVIDE RECESS SHADE POCKET ABOVE WINDOW Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 3/2/2016 5:11:59 PM A5.7 BUILDING SECTIONS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/4" = 1'-0" 1 Section 11 1/4" = 1'-0" 2 Section 12 No. Revision Date Revision Description 04/11/16