Loading...
HomeMy WebLinkAboutB16-0031_A6.10_1478903191.pdfGRID LINE T.O. PLATE RE: ELEVS AND SECTIONS RE: ROOF PLAN 8X8 WOOD STRUT STL. BEAM RE: STRUCT. 12 RE: ROOF PLAN STANDING SEAM METAL ROOFING ASSEMBLY RE: ELEVATIONS AND SPEC HIGH TEMP VYCOR ICE AND WATER SHIELD - EXTENDS UP WALL 3' MIN. RE: SPEC 6 1/8" INSULATION PANEL: 5/8" PLYWOOD SHEATHING GLUED TO 5 1/2" CONTINUOUS RIGID FOAM INSULATION PANEL RE: SPEC 6X10 WOOD RAFTERS @ 48" O.C. INTERIOR CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. GROUT / MORTAR UP TO BOTTOM OF DRAINAGE MEMBRANE BUT DO NOT BLOCK. ROOFS TO BE PROTECTED THROUGHOUT WITH ENGINEERED SNOW GUARDS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: ROOF PLAN FOR LOCATION 2X6 T&G DECKING W/ 1/8" X 1/8" GAP BETWEEN BOARDS EXTERIOR *SIM NOTE INDICATES EAVE W/O WOOD BEAM AND STRUT 9" SEE ELEVATIONS 3" 11 7/8" SIDING RE: ELEVATIONS FOR TYPE AND LOCATIONS. GRID LINE RAFTERS OR GLULAM RE: STRUCT./SPEC. CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 1/2" 1/2" 2 5/8" INSULATION PANEL CONSISTING OF: 2" OF RIGID FOAM GLUED TO 5/8" PLYWOOD TOP SHEET R -12.9+/- SCREW TO WALL W/ MIN. 5" LONG SCREWS IN PATTERN PER DETAIL 5/A6.3 AND PER PANEL MANUF. RECOMMENDATION RE: SPEC SIDING RE: ELEVATIONS FOR TYPE / NOTES AND FINISHED SCHEDULE 3D DRAINAGE MEDIUM CONT. BEHIND STONE TO AIR VENT MATERIAL AT TOP OF WOOD SIDING. HOLD DOWN 1/2" FROM B.O. SIDING 4' X8' - (30) FASTENERS/BD. 3" 1' - 9" 2' - 0" 2' - 0" 1' - 9" 3" 1' - 0" 8" 8" 8" 8" 4" PROVIDE FASTENERS @ MIN 8" O.C. AND PER INSULATION PANEL MANUFACTURER RECOMMENDATIONS PROVIDE BLOCKING FOR FASTENERS AS RECOMMENDED BY PANEL MANUFACTURER FLASHING EXTENDS OVER STANDING SEAM ROOFING 6" MIN. AND OVER 2X BUILD UP AND UP WALL UNDER BUILDING 6" MIN. ROOF SHEATHING RE: STRUCT. WOOD I-JOIST RE: STRUCT. BLKG. RE: STRUCT. FILL CAVITY W/ BLOWN-IN INSULATION RE: SPEC STANDING SEAM ROOFING RE: _ / A_._ VYCOR ICE AND WATER SHIELD - EXTENDS UP WALL 3' MIN. RE: SPEC 6 1/8" INSULATION PANEL WITH 5/8" PLYWOOD SHEATHING GLUED TO 5 1/2" CONTINUOUS RIGID FOAM INSULATION PANEL RE: SPEC SLOPE RE: ROOF PLAN / SECTIONS GRID LINE FILL CAVITY W/ BLOWN- IN INSULATION RE: SPEC. TYPICAL STONE VENEER ASSEMBLY RE: DETAIL 1/A6.1 2X LEDGER RE: STRUCTURAL DRAINAGE MEDIUM AND AIR FILTRATION BARRIER LAPS OVER FLASHING TO ALLOW WALL TO DRAIN SOLID WOOD BLOCKING RE: STRUCT. MIN 8" MIN 3" 11 7/8" 4" X 4" STL. ANGLE LAG BOLTDE INTO SOLID WOOD BLOCKING. GRID LINE TYPICAL STONE VENEER WALL ASSEMBLY SEE 1/A6.1 T.O. PLATE RE: ELEVS AND SECTIONS 8X8 WOOD STRUT 8X14 WOOD BEAM RE: STRUCT. STANDING SEAM METAL ROOFING ASSEMBLY RE: ELEVATIONS AND SPEC 6X10 WOOD RAFTERS @ 50 1/2" O.C. GARAGE CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. GROUT / MORTAR UP TO BOTTOM OF DRAINAGE MEMBRANE BUT DO NOT BLOCK. ROOFS TO BE PROTECTED THROUGHOUT WITH ENGINEERED SNOW GUARDS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: ROOF PLAN FOR LOCATION 2X6 T&G DECKING W/ 1/8" X 1/8" GAP BETWEEN BOARDS EXTERIOR *SIM NOTE INDICATES EAVE W/O WOOD BEAM AND STRUT ICE AND WATERSHIELD CONT. UP WALL 36" MIN. RE: SPEC. 2X6 BLOCKING BUILDUP RE: STRUCT. TYP. WOOD SIDING SEE 7/A6.4 LAP SELF ADHERING BITUTHANE FLASHING OVER COPPER WALL FLASHING 3" 9" 5/8" TYPE 'X' GWB @ GARAGE WALLS AND CEILING SIMPSON HANGER RE: STRUCT. 12 3 1/2" 16.3° 2X6 FASCIA GRID LINE TYPICAL STONE VENEER WALL ASSEMBLY SEE 1/A6.1 T.O. PLATE RE: ELEVS AND SECTIONS 8X8 WOOD STRUT 8X14 WOOD BEAM RE: STRUCT. STANDING SEAM METAL ROOFING ASSEMBLY RE: ELEVATIONS AND SPEC 6X10 WOOD RAFTERS RE: STRUCT. GARAGE CONT. BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. GROUT / MORTAR UP TO BOTTOM OF DRAINAGE MEMBRANE BUT DO NOT BLOCK. SEE 3/A6.10 ROOFS TO BE PROTECTED THROUGHOUT WITH ENGINEERED SNOW GUARDS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: ROOF PLAN FOR LOCATION 2X6 T&G DECKING W/ 1/8" X 1/8" GAP BETWEEN BOARDS EXTERIOR *SIM NOTE INDICATES EAVE W/O WOOD BEAM AND STRUT ICE AND WATERSHIELD CONT. UP WALL 36" MIN. RE: SPEC. 2X10 BLOCKING BUILDUP RE: STRUCT. 3" 9" 5/8" TYPE 'X' GWB @ GARAGE WALLS AND CEILING SIMPSON HANGER RE: STRUCT. 12 3 1/2" 16.3° TYP. COPPER SHINGLE SIDING SEE 11/A6.4 LAP SELF ADHERING BITUTHANE FLASHING OVER COPPER FLASHING INTERIOR 3D DRAINAGE MEDIUM BEHIND STONE CONT. UP OVER T.O. STONE. RE: SPEC. VALLEY FLASHING WITH SPLASH DIVERTER LAP 2ND LAYER OF W.P. MEMBRANE MIN. 3" OVER FLASHING AND 3'-0" MIN. UP VALLEY ROOF SHEATHING RE: STRUCT. RAFTERS RE: STRUCT. BLOWN IN CELLULOSE INSULATION FINISHED CEILING RE: RCP PROVIDE HEAT TAPE ON EACH SIDE OF ALL ROOF VALLEYS EACH SIDE TO BE SEPARATE WIRE SO IF ONE FAILS THE OTHER STILL WORKS OVERFRAMING SYNTHETIC SHAKE ROOFING 9" FLASHING COVERS EDGE OF STANDING SEAM ROOFING SYNTHETIC SHINGLE ROOFING ROOF SHEATHING RE: STRUCT. WOOD I-JOIST RE: STRUCT. BLKG. RE: STRUCT. BLOWN IN INSULATION RE: SPEC AND COVER SHEET OVER FRAMED AREA UPPER ROOF UNDERLAYMENT LAP OVER VALLEY FLASHING MIN. 4" STANDING SEAM METAL ROOFING VYCOR ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE ROOF TRANSITION RE: SPEC 6 1/8" INSULATION PANEL WITH 5/8" PLYWOOD SHEATHING GLUED TO 5 1/2" CONTINUOUS RIGID FOAM INSULATION PANEL RE: SPEC. MAY STACK 2 OR MORE LAYER OF FOAM TO OBTAIN R-25 AND 5 1/2" INSULATION SLOPE RE: ROOF PLAN / SECTIONS SLOPE RE:ROOF PLAN /SECTIONS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 3/2/2016 5:13:22 PM A6.10 ROOF DETAILS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1 1/2" = 1'-0" 1 TYP. ROOF EAVE @STANDING SEAM W/ WOOD BEAM AND STRUT 6" = 1'-0" 3 BUG SCREEN DETAIL @ ROOF EAVE 1 1/2" = 1'-0" 8 FASTENER DETAIL @ INSULATION PANEL 1 1/2" = 1'-0" 2 ROOF TO WALL CONNECTION @ STONE VENEER 1 1/2" = 1'-0" 7 ROOF EAVE @ WOOD BEAM AND STRUT @ GARAGE 1 1/2" = 1'-0" 4 ROOF EAVE @ WOOD BEAM AND STRUT @ GARAGE 2 1 1/2" = 1'-0" 6 ROOF VALLEY FLASHING DETAIL @ SYNTHETIC SHAKE ROOF 1 1/2" = 1'-0" 5 STANDING SEAM ROOF TO SYNTHETIC SHAKE ROOF TRANSITION No. Revision Date Revision Description 04/11/16