HomeMy WebLinkAboutB16-0031_A6.10_1478903191.pdfGRID
LINE
T.O. PLATE
RE: ELEVS AND SECTIONS
RE: ROOF PLAN
8X8 WOOD STRUT
STL. BEAM RE: STRUCT.
12
RE:
ROOF
PLAN
STANDING SEAM METAL ROOFING ASSEMBLY
RE: ELEVATIONS AND SPEC
HIGH TEMP VYCOR ICE AND
WATER SHIELD - EXTENDS UP
WALL 3' MIN.
RE: SPEC
6 1/8" INSULATION PANEL: 5/8" PLYWOOD
SHEATHING GLUED TO 5 1/2" CONTINUOUS
RIGID FOAM INSULATION PANEL
RE: SPEC
6X10 WOOD RAFTERS @
48" O.C.
INTERIOR
CONT. BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO
CREATE MIN 1/2" VENT AT TOP OF THE WALL.
GROUT / MORTAR UP TO BOTTOM OF
DRAINAGE MEMBRANE BUT DO NOT BLOCK.
ROOFS TO BE PROTECTED
THROUGHOUT WITH ENGINEERED
SNOW GUARDS PER MANF.
RECOMMENDATIONS PER ROOF
PITCH AND SNOW LOADS RE: ROOF
PLAN FOR LOCATION
2X6 T&G DECKING W/ 1/8"
X 1/8" GAP BETWEEN
BOARDS
EXTERIOR
*SIM NOTE INDICATES
EAVE W/O WOOD BEAM
AND STRUT
9"
SEE ELEVATIONS
3"
11 7/8"
SIDING RE: ELEVATIONS FOR
TYPE AND LOCATIONS.
GRID
LINE
RAFTERS OR GLULAM
RE: STRUCT./SPEC.
CONT. BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO
CREATE MIN 1/2" VENT AT TOP OF THE
WALL.
1/2"
1/2"
2 5/8" INSULATION PANEL CONSISTING OF:
2" OF RIGID FOAM GLUED TO 5/8" PLYWOOD
TOP SHEET R -12.9+/- SCREW TO WALL W/
MIN. 5" LONG SCREWS IN PATTERN PER
DETAIL 5/A6.3 AND PER PANEL MANUF.
RECOMMENDATION RE: SPEC
SIDING
RE: ELEVATIONS FOR TYPE / NOTES
AND FINISHED SCHEDULE
3D DRAINAGE MEDIUM CONT. BEHIND
STONE TO AIR VENT MATERIAL AT TOP OF
WOOD SIDING. HOLD DOWN 1/2" FROM
B.O. SIDING
4' X8' - (30) FASTENERS/BD.
3" 1' - 9" 2' - 0" 2' - 0" 1' - 9" 3"
1' - 0" 8" 8" 8" 8" 4"
PROVIDE FASTENERS @ MIN 8" O.C. AND PER
INSULATION PANEL MANUFACTURER RECOMMENDATIONS
PROVIDE BLOCKING FOR FASTENERS
AS RECOMMENDED BY PANEL
MANUFACTURER
FLASHING EXTENDS OVER
STANDING SEAM ROOFING
6" MIN. AND OVER 2X BUILD
UP AND UP WALL UNDER
BUILDING 6" MIN.
ROOF SHEATHING RE: STRUCT.
WOOD I-JOIST RE: STRUCT.
BLKG. RE: STRUCT.
FILL CAVITY W/
BLOWN-IN
INSULATION RE: SPEC
STANDING SEAM ROOFING
RE: _ / A_._
VYCOR ICE AND WATER
SHIELD - EXTENDS UP
WALL 3' MIN.
RE: SPEC
6 1/8" INSULATION PANEL WITH
5/8" PLYWOOD SHEATHING
GLUED TO 5 1/2" CONTINUOUS
RIGID FOAM INSULATION PANEL
RE: SPEC
SLOPE RE:
ROOF PLAN /
SECTIONS
GRID
LINE
FILL CAVITY W/ BLOWN-
IN INSULATION RE:
SPEC.
TYPICAL STONE VENEER
ASSEMBLY RE: DETAIL 1/A6.1
2X LEDGER RE: STRUCTURAL
DRAINAGE MEDIUM AND
AIR FILTRATION BARRIER
LAPS OVER FLASHING TO
ALLOW WALL TO DRAIN
SOLID WOOD BLOCKING RE:
STRUCT.
MIN 8"
MIN 3"
11 7/8"
4" X 4" STL. ANGLE LAG
BOLTDE INTO SOLID WOOD
BLOCKING.
GRID
LINE
TYPICAL STONE VENEER WALL ASSEMBLY
SEE 1/A6.1
T.O. PLATE
RE: ELEVS AND SECTIONS
8X8 WOOD STRUT
8X14 WOOD BEAM RE: STRUCT.
STANDING SEAM METAL
ROOFING ASSEMBLY
RE: ELEVATIONS AND SPEC
6X10 WOOD RAFTERS @
50 1/2" O.C.
GARAGE
CONT. BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO
CREATE MIN 1/2" VENT AT TOP OF THE WALL.
GROUT / MORTAR UP TO BOTTOM OF
DRAINAGE MEMBRANE BUT DO NOT BLOCK.
ROOFS TO BE PROTECTED
THROUGHOUT WITH ENGINEERED
SNOW GUARDS PER MANF.
RECOMMENDATIONS PER ROOF
PITCH AND SNOW LOADS RE: ROOF
PLAN FOR LOCATION
2X6 T&G DECKING W/ 1/8"
X 1/8" GAP BETWEEN
BOARDS
EXTERIOR
*SIM NOTE INDICATES
EAVE W/O WOOD BEAM
AND STRUT
ICE AND WATERSHIELD CONT.
UP WALL 36" MIN. RE: SPEC.
2X6 BLOCKING BUILDUP RE: STRUCT.
TYP. WOOD SIDING
SEE 7/A6.4
LAP SELF ADHERING BITUTHANE
FLASHING OVER COPPER WALL
FLASHING
3"
9"
5/8" TYPE 'X' GWB @ GARAGE
WALLS AND CEILING
SIMPSON HANGER RE: STRUCT.
12 3
1/2"
16.3°
2X6 FASCIA
GRID
LINE
TYPICAL STONE VENEER WALL ASSEMBLY
SEE 1/A6.1
T.O. PLATE
RE: ELEVS AND SECTIONS
8X8 WOOD STRUT
8X14 WOOD BEAM RE:
STRUCT.
STANDING SEAM METAL
ROOFING ASSEMBLY
RE: ELEVATIONS AND SPEC
6X10 WOOD RAFTERS RE:
STRUCT.
GARAGE
CONT. BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO
CREATE MIN 1/2" VENT AT TOP OF THE WALL.
GROUT / MORTAR UP TO BOTTOM OF
DRAINAGE MEMBRANE BUT DO NOT BLOCK.
SEE 3/A6.10
ROOFS TO BE PROTECTED
THROUGHOUT WITH ENGINEERED
SNOW GUARDS PER MANF.
RECOMMENDATIONS PER ROOF
PITCH AND SNOW LOADS RE: ROOF
PLAN FOR LOCATION
2X6 T&G DECKING W/ 1/8"
X 1/8" GAP BETWEEN
BOARDS
EXTERIOR
*SIM NOTE INDICATES
EAVE W/O WOOD BEAM
AND STRUT
ICE AND WATERSHIELD CONT.
UP WALL 36" MIN. RE: SPEC.
2X10 BLOCKING BUILDUP RE: STRUCT.
3"
9"
5/8" TYPE 'X' GWB @ GARAGE
WALLS AND CEILING
SIMPSON HANGER RE: STRUCT.
12
3
1/2"
16.3°
TYP. COPPER SHINGLE SIDING
SEE 11/A6.4
LAP SELF ADHERING BITUTHANE
FLASHING OVER COPPER
FLASHING
INTERIOR
3D DRAINAGE MEDIUM BEHIND STONE
CONT. UP OVER T.O. STONE. RE: SPEC.
VALLEY FLASHING WITH
SPLASH DIVERTER
LAP 2ND LAYER OF W.P.
MEMBRANE MIN. 3"
OVER FLASHING AND
3'-0" MIN. UP VALLEY
ROOF SHEATHING RE: STRUCT.
RAFTERS RE: STRUCT.
BLOWN IN CELLULOSE
INSULATION
FINISHED CEILING RE: RCP
PROVIDE HEAT TAPE ON
EACH SIDE OF ALL ROOF
VALLEYS EACH SIDE TO BE
SEPARATE WIRE SO IF ONE
FAILS THE OTHER STILL
WORKS
OVERFRAMING
SYNTHETIC SHAKE ROOFING
9"
FLASHING COVERS EDGE OF
STANDING SEAM ROOFING
SYNTHETIC SHINGLE ROOFING
ROOF SHEATHING RE: STRUCT.
WOOD I-JOIST RE: STRUCT.
BLKG. RE: STRUCT.
BLOWN IN INSULATION
RE: SPEC AND COVER SHEET
OVER FRAMED AREA
UPPER ROOF
UNDERLAYMENT LAP
OVER VALLEY FLASHING
MIN. 4"
STANDING SEAM METAL ROOFING
VYCOR ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50%
OVERLAP) FOR FIRST 4' OF ROOF
ABOVE ROOF TRANSITION
RE: SPEC
6 1/8" INSULATION PANEL WITH 5/8"
PLYWOOD SHEATHING GLUED TO 5 1/2"
CONTINUOUS RIGID FOAM INSULATION
PANEL RE: SPEC. MAY STACK 2 OR MORE
LAYER OF FOAM TO OBTAIN R-25 AND 5
1/2" INSULATION
SLOPE RE:
ROOF PLAN /
SECTIONS
SLOPE RE:ROOF PLAN /SECTIONS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
3/2/2016
5:13:22 PM
A6.10
ROOF
DETAILS
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
1
TYP. ROOF EAVE @STANDING SEAM W/
WOOD BEAM AND STRUT
6" = 1'-0"
3
BUG SCREEN DETAIL @ ROOF EAVE
1 1/2" = 1'-0"
8
FASTENER DETAIL @ INSULATION
PANEL
1 1/2" = 1'-0"
2
ROOF TO WALL CONNECTION @ STONE
VENEER
1 1/2" = 1'-0"
7
ROOF EAVE @ WOOD BEAM AND STRUT
@ GARAGE
1 1/2" = 1'-0"
4
ROOF EAVE @ WOOD BEAM AND STRUT
@ GARAGE 2
1 1/2" = 1'-0"
6
ROOF VALLEY FLASHING DETAIL @
SYNTHETIC SHAKE ROOF
1 1/2" = 1'-0"
5
STANDING SEAM ROOF TO SYNTHETIC
SHAKE ROOF TRANSITION
No. Revision Date
Revision
Description
04/11/16