HomeMy WebLinkAboutB16-0031_A7.1_1478903209.pdfGENERAL NOTES:
1.) INSTALL GAS LOG SET AND BURNER PER MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A
COPY OF THE SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY
PROPER INSTALLATION.
2.) INSTALL EXCEL MODEL RIS CHIMNEY @ LIVING ROOM, HEARTH ROOM, AND OUTDOOR FIREPLACES PER
MANUFACTURERS SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE SPECIFICATIONS AND
INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION.
A7.1
4 6
A7.1
ORTAL "FRONT 150"
FIREPLACE
CANTILEVERED 6" CUT
STONE HEARTH
PROJECTS 12" FROM
FACE OF STONE APRON
AND 25" FROM FACE OF
FIREPLACE.
2' - 6 1/16"
1' - 3 1/4"
1/8" STL. PLATE BACK
PANEL AND
FIREPLACE
SURROUND
ATTACHED WITH
FLUSH SQUARE HEAD
SCREWS PAINTED
BLACK TO BE HIDDEN.
6" DEEP X 1/2" THICK
STL. PLATE @ JAMB
HEADER.
OPENING 5' - 1 1/16"
2' - 1"
1' - 7"
U
U
MAIN LEVEL
FINISHED FLOOR
11' - 11 1/4"
UPPER LEVEL
FINISHED FLOOR
23' - 11 1/4"
LOWER LEVEL
FINISHED FLOOR
1' - 6 1/4"
MASON-LITE 42"
ARCHED FRONT
MASONRY FIREPLACE
WRAP COMBUSTIBLE
CONSTRUCTION
WITH 5/8" TYPE X DRYWALL.
MAINTAIN CLEARANCE
PER CODE AND
FIREPLACE FLUE
MANUFACTURER
3"
ORTAL FRONT FACING
"CLEAR 150" FIRPLACE
200 SQ IN WALL VENT BEHIND C-
CHANNEL PER MANUFACTURER.
FAMILY ROOM
001
HEARTH ROOM
111
CLOSET
202
2"
LED LIGHT.
6"
2"
1/2" STL.
PLATE MANTLE
6" DEEP X 1/2" THICK
STL. PLATE @ JAMB
HEADER
55" TV SHOWN ABOVE FIREPLACE.
PROVIDE NICHE IN STONE VENEER
FOR TV BRACKET FOR POWER
AND CONNECTION.
C8X13.7
CANTILEVERED 6" CUT STONE
HEARTH PROJECTS 12" FROM
FACE OF STONE APRON AND 25"
FROM FACE OF FIREPLACE.
1' - 3"
4' - 5"
CONC. SLAB FLUSH WITH
FLOOR PROJECTS 25" IN
FRONT OF FIRE PLACE AND
12" FROM EACH SIDE.
2' - 1"
CRICKET RE: ROOF
PLAN
CUSTOM STL. CHIMNEY
CAP SURROUND. SEE
1/A7.1B
4" CUT STONE CHIMNEY CAP
4"
TYP. STONE VENEER
ICC RIS CHIMNEY INSTALLED
PER MANUF. SPEC.
4" COLORADO BUFF CUT
STONE SLAB W/ SNAPPED EDGE
PROJECTS 6" BEYOND FACE OF
UPPER STONE VENEER.
FIRE PLACE FLUE INSTALLED
PER MANUF. SPEC.
PROVIDE WOOD BUILD-UP
TO SUPPORT STONE
VENEER
WOOD HEADER OVER
FIREBOX OPENING RE:
STRUCT.
10" DIA. DUCT FOR MAKE-IP AIR
STL. ANGLE FOR
ARCHED FRONT OF
MASONRY FIREPLACE
STL. BEAM FLOORING WITH METAL
DECKING IN 4" CONC. SLAB
DURA-ROCK. 10"
2"
A6.10
2
1' - 0"
4"
OBSTRUCTION FRFEE 4" MIN.
SPACING FROM T.O. FIREPLACE
FRAME. RE: MANUF. SPEC.
4"
STONE VENEER APRON
A7.1B
1
FAMILY ROOM
001
5' - 0 1/4"
3' - 6" C8X13.7
1/2" STL.
PLATE MANTLE
6" DEEP X 1/2" THICK
STL. PLATE @ JAMB
HEADER
55" TV SHOWN ABOVE FIRE PLACE.
PROVIDE NICHE IN STONE VENEER
FOR TV BRACKET FOR POWER AND
CONNECTION
CANTILEVERED 6" CUT STONE
HEARTH PROJECTS 12" FROM FACE
OF STONE VENNER AND 25" FROM
FACE OF FIREPLACE.
4" 4' - 1"
2"
ORTAL FRONT FACING
"CLEAR 150" FIRPLACE
TV
DASHED LINE REPRESENTS
60" TV DIMENSIONS
TV
8' - 5 3/4"
3' - 6"
3' - 10" 4' - 5"
DASHED LINES
REPRESENTS
60" TV DIMENSIONS.
PROVIDE NICHE IN STONE
VENEER
FOR TV BRACKET FOR
POWER AND
CONNECTION
MASON-LITE 42" ARCHED FRONT FIREPLACE
2" 4' - 8"
1/8" STEEL PLATE BACK PANEL AND
FIREPLACE SURROUND ATTACHED W/
FLUSH SQUARE HEAD SCREWS PAINTED
BLACK TO BE HIDDEN
2" PROJECTION BEYOND FACE
OF LOWER STONE VENEER.
4" COLORADO BUFF CUT
STONE SLAB W/ SNAPPED EDGE
PROJECTS 6" BEYOND FACE OF
UPPER STONE VENEER.
2" CONC. SLAB FLUSH WITH FLOOR.
PROJECTS 25" IN FRONT OF FIREPLACE
AND 12" TO EACH SIDE.
EQ EQ
LED LIGHT
3" X 72" WALL VENT BEHIND C-
CHANCEL PER MANUFACTURER.
VENT REQUIRES 200 SQ IN MIN.
3"
6' - 3 1/2"
HEARTH ROOM
111
BREAKFAST NOOK
110
6"
6"
ART
1' - 2"
1' - 3" 8"
7' - 0 1/2" 5' - 1 7/8"
144"
12"
6 1/2"
1' - 0"
FRAMING
ARCHED STL. ANGLE SUPPORT
FOR ARCHED FRONT FIREPLACE
ICC RIS CHIMNEY INSTALLED
PER MANUF. SPECS.
6 1/2"
1' - 0" FRAMING
10" DIA. DUCT FOR
MAKE-UP AIR.
RE: MECH PLANS
CHIMNEY INSTALLED PER
MANUF. SPEC.
FRAMING AT EXTERIOR
ASSEMBLY
1' - 0"
6 1/2"
5 1/2"
7' - 11 3/4"
8"
8"
1' - 4 1/4"
MIN. 2" CLR.
10 1/2"10 1/2"
8"
10"
1' - 4 1/4" 10"
10"
LINE OF FRAMING @ EXT. CHIMNEY
A7.1B
1
STONE VENEER APRON
A7.1
4 6
A7.1
U
U
MASON-LITE 42"
ARCHED FRONT
MASONRY
FIREPLACE
OPENING
3' - 6"
5/8" TYPE X DRYWALL
ON ALL SIDES OF
CHIMNEY CHASE
2' - 1"
1' - 0" 1' - 0"
2" CONC. SLAB FLUSH
WITH FLOOR.
PROJECTS 25" IN
FRONT OF FIREPLACE
AND 12" TO EACH SIDE.
8" DIA. DIRECT-VENT BY
DURA VENT CHIMNEY
FROM LOWER LEVEL
FIREPLACE.
5' - 6"
FRAMING
4' - 2"
6
A7.1
R 0' - 4"
R 0' - 8 1/8"
R 0' - 5"
8" DIA. DIRECT-VENT BY
DURA VENT CHIMNEY FROM
LOWER LEVEL FIREPLACE.
14" DIA. ICC CHIMNEY
FROM HEARTH ROOM
FIREPLACE
10" DIA. DUCT WORK FOR
MAKE UP AIR AT RANGE
HOOD
2 1/2" / 12"
1 5/8" / 12" 2 1/2" / 12"
MIN.
1' - 6"
MI N.
1' - 6"
REMOVE ABLE STEEL
SCREEN ON 4 SIDES
CUSTOM STEEL
CHIMNEY CAP SURRUND
1"
1"
STONE CHIMNEY CAP
BELOW
2X6 WOOD FRAMING
BELOW
2X6 WOOD FRAMING
BELOW
1
A7.1B
DS
14" DIA. ICC CHIMNEY FROM
HEARTH ROOM FIREPLACE
10" DIA. DUCT WORK FOR MAKE
UP AIR AT RANGE HOOD
R 0' - 4"
R 0' - 8 1/8"
R 0' - 5"
8" DIA. DIRECT-VENT BY
DURA VENT CHIMNEY FROM
LOWER LEVEL FIREPLACE.
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
3/2/2016
5:13:31 PM
A7.1
FIREPLACE
SHEET
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1/2" = 1'-0" 1
LOWER LEVEL FIREPLACE FLOOR PLAN
1/2" = 1'-0" 6
FIREPLACES SECTION
1/2" = 1'-0"
4
LOWER LEVEL AND HEARTH ROOM
FIREPLACE ELEVATION
5
LOWER LEVEL FIREPLACE
1/2" = 1'-0"
2
HEARTH ROOM FIREPLACE FLOOR PLAN
3
HEARTH ROOM FIREPLACE
1/2" = 1'-0"
7
HEARTH AND LOWER LEVEL CHIMNEY
CAP FLUE PLAN
1/2" = 1'-0"
8
UPPER LEVEL FIREPLACE FLOORPLAN
No. Revision Date
Revision
Description
04/11/16