HomeMy WebLinkAboutB16-0031_A8.1_1478903238.pdfWINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE 1/A6.1 TYP. EXT. STONE SIDING WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
1/4" SEALANT JOINT AND
BACKER ROD DO NOT LET
MORTAR TOUCH WINDOW
USE SANDED CAULK JOINT
AT STONE TO ADJACENT
WINDOW
CUSTOM WOOD JAMB PER EXTENDED WIDTH
TRIM PER INTERIOR DOCUMENTS
2 3/8"
WINDOW RE: WINDOW SCHEDULE
METAL FLASHING
WINDOW SET IN BED
OF SEALANT
CUSTOM SILL PER
INTERIOR DOCUMENTS
TRIM PER INTERIOR DOCUMENTS
2" CUT STONE TOP SILL
SLOPED TO DRAIN
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BUILDING PAPER AND
UNDER WINDOW SILL
TYP. EXT. STONE VENEER
ASSEMBLY. SEE 1/A6.1
GRID
LINE
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE 7/A6.5 FOR TYP. WOOD SIDING
WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
CUSTOM WOOD JAMB PER EXTENDED WIDTH
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
3X3 WOOD TRIM
TRIM PER INTERIOR DOCUMENTS
5 1/2"
2 3/8"
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
SEE 7 / A6.5 FOR TYP. WOOD
SIDING WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
GRID
LINE
CUSTOM SILL PER INTERIOR DOCUMENTS
INTERIOR
EXTERIOR
3X3 WOOD TRIM WITH
SLOPED TOP TO DRAIN
TRIM PER INTERIOR DOCUMENTS
CONTINUOUS 1X4
HORIZONTAL FURRING
STRIPS @ 2'-0" O.C. OVER
3D DRAINAGE MEDIUM AND
AIR INFILTRATION BARRIER
1"
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE 11/A6.5 FOR TYP. COPPER
SHINGLE SIDING WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR EXTERIOR
CUSTOM WOOD JAMB PER EXTENDED WIDTH
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
3X3 WOOD TRIM
TRIM PER INTERIOR DOCUMENTS
2 3/8"
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
SEE 11/A6.5 FOR TYP.
COPPER SHINGLE SIDING
WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
GRID
LINE
CUSTOM SILL PER INTERIOR DOCUMENTS
INTERIOR EXTERIOR
3X3 WOOD TRIM WITH
SLOPED TOP TO DRAIN
TRIM PER INTERIOR DOCUMENTS
2 3/8" 1 1/4"
PROVIDE WEEP
TYPICAL WINDOW HEADER
@ STONE VENEER
IN-FILL W/ SPRAY FOAM EXPANDING
INSULATION AND SHIM AS REQ'D RE:
SPEC
PFSM FLASHING
EXTERIOR
HEADER RE: STRUCT.
TYPICAL WOOD TRIM TO
LAP OVER T.O SHADE
VALANCE
SIDE MOUNT MOTORIZED ROLLER SHADE
W/ EXTRUDED ALUMINUM LUTRON
HOUSING WRAPPED IN WOOD PER SPEC.
LUTRON 100 DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS WITH SHADE
MANUFACTURER RE: RCP
2X BLOCKING
WINDOW RE: WINDOW SCHEDULE
ROLLER SHADE W/ REVERSE ROLL TO AVOID
CONFLICTS WITH WINDOW HANDLE
GRID
LINE
INTERIOR
REMOVABLE 3/4" TRIM
TYP. STONE VENEER ASSEMBLY
SEE 1/A6.1
5 1/4"
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
5"
B.O. HEADER
RE: ELEVATIONS
4 3/4"
5 5/8"
IN-FILL W/ SPRAY FOAM EXPANDING
INSULATION AND SHIM AS REQ'D RE:
SPEC
PFSM FLASHING
EXTERIOR
HEADER RE: STRUCT.
TYPICAL WOOD TRIM TO
LAP OVER T.O SHADE
VALANCE
8 3/8"
SIDE MOUNT MOTORIZED ROLLER SHADE
W/ EXTRUDED ALUMINUM LUTRON
HOUSING WRAPPED IN WOOD PER SPEC.
LUTRON 100 DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS WITH SHADE
MANUFACTURER RE: RCP
2X BLOCKING
WINDOW RE: WINDOW SCHEDULE
ROLLER SHADE W/ REVERSE ROLL TO AVOID
CONFLICTS WITH WINDOW HANDLE
GRID
LINE
INTERIOR
REMOVABLE 3/4" TRIM
5"
WOOD SIDING RE: SPEC AND ELEVS
FOR LOCATION
5 3/16"
3"
2 3/8"
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
AND CONT. UP WALL
4 3/4"
B.O. HEADER
RE: ELEVATIONS
4 9/16" 5 5/8"
IN-FILL W/ SPRAY FOAM EXPANDING
INSULATION AND SHIM AS REQ'D RE:
SPEC
PFSM FLASHING
EXTERIOR
HEADER RE: STRUCT.
TYPICAL WOOD TRIM TO
LAP OVER T.O SHADE
VALANCE
8 3/8"
SIDE MOUNT MOTORIZED ROLLER SHADE
W/ EXTRUDED ALUMINUM LUTRON
HOUSING WRAPPED IN WOOD PER SPEC.
LUTRON 100 DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS WITH SHADE
MANUFACTURER RE: RCP
2X BLOCKING
WINDOW RE: WINDOW SCHEDULE
ROLLER SHADE W/ REVERSE ROLL TO AVOID
CONFLICTS WITH WINDOW HANDLE
GRID
LINE
INTERIOR
REMOVABLE 3/4" TRIM 5"
COPPER SHINGLE SIDING RE:
SPEC AND ELEVS FOR LOCATION
5 1/4"
3"
2 3/8"
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
AND CONT. UP WALL
4 3/4"
B.O. HEADER
RE: ELEVATIONS
5 5/8"
IN-FILL W/ SPRAY FOAM EXPANDING
INSULATION AND SHIM AS REQ'D RE:
SPEC
PFSM FLASHING
EXTERIOR
HEADER RE: STRUCT.
HEAD TRIM AND BACKER BOARD
REMOVABLE FOR MAINTENANCE.
PROVIDE TRIM SCREWS.
SIDE MOUNT MOTORIZED ROLLER SHADE
W/ EXTRUDED ALUMINUM LUTRON
HOUSING WRAPPED IN WOOD PER SPEC.
LUTRON 100 DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS WITH SHADE
MANUFACTURER RE: RCP
2X BLOCKING
DOOR RE: DOOR SCHEDULE
ROLLER SHADE W/ REVERSE ROLL TO AVOID
CONFLICTS WITH WINDOW HANDLE
GRID
LINE
INTERIOR
5"
WOOD SIDING RE: SPEC AND ELEVS
FOR LOCATION
2 3/8"
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
AND CONT. UP WALL
B.O. HEADER
RE: ELEVATIONS
4 11/16"
JAMB EXTENSION
5 5/8"
1" 7 1/4"
WINDOW RE: WINDOW SCHEDULE
IN-FILL W/ SPRAY FOAM INSULATION
AND SHIM AS REQ'D
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
1/4" SEALANT JOINT AND BACKER ROD
SEPARATE BRONZE METAL PANELS
FROM WINDOWS W/ SEALANT AND
ICE AND WATER SHIELD TYPE
STRIP FLASHING
CUSTOM WOOD JAMB PER EXTENDED WIDTH
TRIM PER INTERIOR DOCUMENTS
3D DRAINAGE MEDIUM LAPS OVER
WATERPROOF MEMBRANE AND BUILDING
PAPER
FINISHED FLOOR RE: PLANS, SPEC &
INTERIORS
SEE 4/A6.6 FOR TYP. FLOOR/WALL
ASSEMBLY
STRUCTURAL HEADER RE: STRUCT.
8X12 APPLIED TIMBER BEAMS
ALIGN B.O. OF TIMBER BEAMS
AND B.O. REMOVABLE TRIM.
REMOVABLE TRIM FOR ACCESS TO
MOTORIZED SHADE
EXTERIOR
8 3/8"
GRID
LINE
INTERIOR
5 1/2"
3"
2 3/8"
4 3/4"
B.O. HEADER
RE: ELEVATIONS
6"
3 3/4"
WINDOW RE: WINDOW SCHEDULE
INTERIOR
IN-FILL W/ SPRAY FOAM EXPANDING
INSULATION AND SHIM AS REQ'D RE:
SPEC
PFSM FLASHING
SIDE MOUNT MOTORIZED ROLLER SHADE
W/ EXTRUDED ALUMINUM LUTRON
HOUSING WRAPPED IN WOOD PER SPEC.
LUTRON 100 DIMENSIONS SHOWN. VERIFY
ALL DIMENSIONS WITH SHADE
MANUFACTURER RE: RCP
ROLLER SHADE W/ REVERSE ROLL TO AVOID
CONFLICTS WITH WINDOW HANDLE
WOOD SIDING RE: SPEC AND ELEVS
FOR LOCATION
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
3D DRAINAGE MEDIUM LAPS
OVER BUILDING PAPER LAPS
OVER TOP OF FLASHING 1 1/2"
MIN AND CONT. UP WALL
11 7/8"
6 1/8"
11 1/4"
T.O. PLYWOOD
RE: SECTIONS/PLANS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
3" = 1'-0"
3/2/2016
5:14:53 PM
A8.1
WINDOW
AND DOOR
DETAILS
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
3" = 1'-0"
2
WINDOW JAMB DETAIL @ STONE
VENEER
3" = 1'-0"
3
WINDOW SILL DETAIL @ STONE VENEER
3" = 1'-0"
5
WINDOW JAMB DETAIL @ WOOD SIDING
3" = 1'-0" 6
WINDOW SILL DETAIL @ WOOD SIDING
3" = 1'-0"
8
WINDOW JAMB DETAIL @ COPPER
SHINGLES
3" = 1'-0"
9
WINDOW SILL DETAIL @ COPPER
SHINGLES
3" = 1'-0" 1
SHADE DETAIL @ STONE VENEER
3" = 1'-0" 4
SHADE DETAIL @ WOOD SIDING
3" = 1'-0" 7
SHADE DETAIL @ COPPER SIDING
3" = 1'-0" 10
SHADE DETAIL @ PATIO DOOR @ WOOD
SIDING
3" = 1'-0" 11
WINDOW JAMB DETAIL @ BRONZE
METAL PANEL
3" = 1'-0"
12
SHADE DETAIL @ KITCHEN TIMBER
BEAM
No. Revision Date
Revision
Description
04/11/16