HomeMy WebLinkAboutB16-0031_A8.1_1478903238.pdfWINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE 1/A6.1 TYP. EXT. STONE SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE 1/4" SEALANT JOINT AND BACKER ROD DO NOT LET MORTAR TOUCH WINDOW USE SANDED CAULK JOINT AT STONE TO ADJACENT WINDOW CUSTOM WOOD JAMB PER EXTENDED WIDTH TRIM PER INTERIOR DOCUMENTS 2 3/8" WINDOW RE: WINDOW SCHEDULE METAL FLASHING WINDOW SET IN BED OF SEALANT CUSTOM SILL PER INTERIOR DOCUMENTS TRIM PER INTERIOR DOCUMENTS 2" CUT STONE TOP SILL SLOPED TO DRAIN LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BUILDING PAPER AND UNDER WINDOW SILL TYP. EXT. STONE VENEER ASSEMBLY. SEE 1/A6.1 GRID LINE WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE 7/A6.5 FOR TYP. WOOD SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR CUSTOM WOOD JAMB PER EXTENDED WIDTH LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE SEALANT JOINT AND BACKER ROD 3X3 WOOD TRIM TRIM PER INTERIOR DOCUMENTS 5 1/2" 2 3/8" WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT SEE 7 / A6.5 FOR TYP. WOOD SIDING WALL ASSEMBLY LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BLDG. PAPER AND UNDER WINDOW SILL GRID LINE CUSTOM SILL PER INTERIOR DOCUMENTS INTERIOR EXTERIOR 3X3 WOOD TRIM WITH SLOPED TOP TO DRAIN TRIM PER INTERIOR DOCUMENTS CONTINUOUS 1X4 HORIZONTAL FURRING STRIPS @ 2'-0" O.C. OVER 3D DRAINAGE MEDIUM AND AIR INFILTRATION BARRIER 1" WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE 11/A6.5 FOR TYP. COPPER SHINGLE SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR CUSTOM WOOD JAMB PER EXTENDED WIDTH LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE SEALANT JOINT AND BACKER ROD 3X3 WOOD TRIM TRIM PER INTERIOR DOCUMENTS 2 3/8" WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT SEE 11/A6.5 FOR TYP. COPPER SHINGLE SIDING WALL ASSEMBLY LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BLDG. PAPER AND UNDER WINDOW SILL GRID LINE CUSTOM SILL PER INTERIOR DOCUMENTS INTERIOR EXTERIOR 3X3 WOOD TRIM WITH SLOPED TOP TO DRAIN TRIM PER INTERIOR DOCUMENTS 2 3/8" 1 1/4" PROVIDE WEEP TYPICAL WINDOW HEADER @ STONE VENEER IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING EXTERIOR HEADER RE: STRUCT. TYPICAL WOOD TRIM TO LAP OVER T.O SHADE VALANCE SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING WINDOW RE: WINDOW SCHEDULE ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE GRID LINE INTERIOR REMOVABLE 3/4" TRIM TYP. STONE VENEER ASSEMBLY SEE 1/A6.1 5 1/4" LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 5" B.O. HEADER RE: ELEVATIONS 4 3/4" 5 5/8" IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING EXTERIOR HEADER RE: STRUCT. TYPICAL WOOD TRIM TO LAP OVER T.O SHADE VALANCE 8 3/8" SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING WINDOW RE: WINDOW SCHEDULE ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE GRID LINE INTERIOR REMOVABLE 3/4" TRIM 5" WOOD SIDING RE: SPEC AND ELEVS FOR LOCATION 5 3/16" 3" 2 3/8" LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL 4 3/4" B.O. HEADER RE: ELEVATIONS 4 9/16" 5 5/8" IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING EXTERIOR HEADER RE: STRUCT. TYPICAL WOOD TRIM TO LAP OVER T.O SHADE VALANCE 8 3/8" SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING WINDOW RE: WINDOW SCHEDULE ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE GRID LINE INTERIOR REMOVABLE 3/4" TRIM 5" COPPER SHINGLE SIDING RE: SPEC AND ELEVS FOR LOCATION 5 1/4" 3" 2 3/8" LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL 4 3/4" B.O. HEADER RE: ELEVATIONS 5 5/8" IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING EXTERIOR HEADER RE: STRUCT. HEAD TRIM AND BACKER BOARD REMOVABLE FOR MAINTENANCE. PROVIDE TRIM SCREWS. SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING DOOR RE: DOOR SCHEDULE ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE GRID LINE INTERIOR 5" WOOD SIDING RE: SPEC AND ELEVS FOR LOCATION 2 3/8" LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL B.O. HEADER RE: ELEVATIONS 4 11/16" JAMB EXTENSION 5 5/8" 1" 7 1/4" WINDOW RE: WINDOW SCHEDULE IN-FILL W/ SPRAY FOAM INSULATION AND SHIM AS REQ'D LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE 1/4" SEALANT JOINT AND BACKER ROD SEPARATE BRONZE METAL PANELS FROM WINDOWS W/ SEALANT AND ICE AND WATER SHIELD TYPE STRIP FLASHING CUSTOM WOOD JAMB PER EXTENDED WIDTH TRIM PER INTERIOR DOCUMENTS 3D DRAINAGE MEDIUM LAPS OVER WATERPROOF MEMBRANE AND BUILDING PAPER FINISHED FLOOR RE: PLANS, SPEC & INTERIORS SEE 4/A6.6 FOR TYP. FLOOR/WALL ASSEMBLY STRUCTURAL HEADER RE: STRUCT. 8X12 APPLIED TIMBER BEAMS ALIGN B.O. OF TIMBER BEAMS AND B.O. REMOVABLE TRIM. REMOVABLE TRIM FOR ACCESS TO MOTORIZED SHADE EXTERIOR 8 3/8" GRID LINE INTERIOR 5 1/2" 3" 2 3/8" 4 3/4" B.O. HEADER RE: ELEVATIONS 6" 3 3/4" WINDOW RE: WINDOW SCHEDULE INTERIOR IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE WOOD SIDING RE: SPEC AND ELEVS FOR LOCATION LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL 11 7/8" 6 1/8" 11 1/4" T.O. PLYWOOD RE: SECTIONS/PLANS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 3" = 1'-0" 3/2/2016 5:14:53 PM A8.1 WINDOW AND DOOR DETAILS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 3" = 1'-0" 2 WINDOW JAMB DETAIL @ STONE VENEER 3" = 1'-0" 3 WINDOW SILL DETAIL @ STONE VENEER 3" = 1'-0" 5 WINDOW JAMB DETAIL @ WOOD SIDING 3" = 1'-0" 6 WINDOW SILL DETAIL @ WOOD SIDING 3" = 1'-0" 8 WINDOW JAMB DETAIL @ COPPER SHINGLES 3" = 1'-0" 9 WINDOW SILL DETAIL @ COPPER SHINGLES 3" = 1'-0" 1 SHADE DETAIL @ STONE VENEER 3" = 1'-0" 4 SHADE DETAIL @ WOOD SIDING 3" = 1'-0" 7 SHADE DETAIL @ COPPER SIDING 3" = 1'-0" 10 SHADE DETAIL @ PATIO DOOR @ WOOD SIDING 3" = 1'-0" 11 WINDOW JAMB DETAIL @ BRONZE METAL PANEL 3" = 1'-0" 12 SHADE DETAIL @ KITCHEN TIMBER BEAM No. Revision Date Revision Description 04/11/16