HomeMy WebLinkAboutinspector_summary_32427_05-02-2017-6698.pdfInspection Result:Pass
Inspector:Derek Place
Permit Type Inspection Type Address
Construction Minor Framing 3090 BOOTH CREEK DR (210102304004) (2101023040048)
Inspection Date:05/02/2017
Permit #:B16-0031.001
TMK:2101023040048
Comments:
1. Install flat top plate strapping where plates are cut out for steel columns.
2. Retail sheer-wall where overdriven.
3. Inspector Signature
4. Applicant Signature
5. Check hold down locations where questioned with engineer.