HomeMy WebLinkAboutB16-0032_A402_1478899214.pdf5
4
A202
4
2
1
3
NEW STOREFRONT TO
MATCH EXISTING SPA;
U-VALUE TO MEET
TOWN OF VAIL
REQUIREMENTS
ADD POWER FOR
POWERED SHADE
MOVE ELECTRIC
PANEL FROM
EXISTING BATHROOM
WALL TO THIS WALL
A201
1
EXISTING COLUMN; NO
OTHER STRUCTURAL
CHANGES
INSTALL VINYL
COVE BASE ON ALL
WALLS TO MATCH
EXISTING GYM
W1
W3
W1
W1
W2
REMOVE EXISTING
DOOR AND INFILL
WITH CMU
INSTALL INDIVIDUAL 1-
HOUR FIRE
PROTECTION PER IBC
TABLE 721.1 (1)
SECTION 1-7.1
INFILL EXISTING
OPENING
NEW DOOR
BETWEEN EXISTING
GYM AND NEW
GYM
NEW CONSTRUCTION
KEY
INSTALL GWB ON
7/8" FURRING STRIPS
TO ALIGN WITH
STOREFRONT
WINDOW WALL
W1 NEW OR EXISTING GYPSUM BOARD PARTITION ON 2 x 4 METAL STUDS INSULATED
(1) Layer 5/8" Type X gypsum board on each side of 2 x 4 metal studs
16" O.C. with unfaced fiberglass batts.
W2 GYPSUM BOARD PARTITION ON 2 x 6 METAL STUDS INSULATED
(1) Layer 5/8" Type X gypsum board on each side of 2 x 6 metal studs
16" O.C. with R-21 spray foam insulation.
W3 NEW GYPSUM BOARD ON 7/8" FURRING
(1) Layer 5/8" Type X gypsum board on 7/8" furring 16" O.C. on existing or new
CMU
WALL SYSTEMS:
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
600 Vail Valley Drive
Vail, Colorado 81657
A402
ENLARGED
GYM PLAN
Northwoods Gym Expansion
PROJECT # 1604
03/02/16
PRICING
1/2" = 1'-0"
A402
1 GYM EXPANSION PLAN
04/28/16