HomeMy WebLinkAboutB16-0034_M.1_1478897045.pdfGARAGE ELEV
100'-0"
ENTRY ELEV
105'-6"
REC. ELEV
100'-0"
DN 5'-6" UP 5'-6"
GARAGE
MUD
ROOM/
LAUNDRY
ENTRY
REC
ROOM
BED 1
BED 2
BED 3
MECH
PATIO
100'-0"
UP 5'
D W
ENTRY PATIO ELEV
105'-6"
dropped
dropped
BATH FAN VENT THRU WALL
BATH FAN VENTS THRU WALL
BATH FAN VENT THRU WALL
5
4 3 1
STAGE REGULATOR
1" CSST
5
GAS METER
(2) WHN 399 "KNIGHT" HIGH ALTITUDE
(2) 4" PVC INTAKE VENTS
SIT080 "LOCHENVAR" INDIRECT HWH
CONDENSING BOILERS (95% AFUE)
3/4" CSST
2 1" CSST
1" CSST
BATH FAN VENTS THRU WALL DRYER VENT THRU WALL
12" MIN. C:C
12" MIN. CLEAR TO OVERHEAD
36" MIN. ABV. ROOF
1/2" CSST
4" PERFORATED PIPE BELOW SLAB
FOR RADON MITIGATION
4" NON-PERFORATED PVC PIPE
UP TO UPPER LEVEL
1" CSST
1
2
(2) 4" PVC EXH. VENTS
1/2" CSST
M-1
2
M-1
3
BACK -FLOW
PREVENTER
PRESSURE
REDUCING VALVE
PRESSURE GA.
SYS. SUPPLY
SENSOR
AIR SEPARATOR
DCW (MAKE UP) IN
EXPANSION
TANK
LOW LOSS
HEADER
NOT TO EXCEED 4 PIPE D. OR 12" APART
BALL VALVE
(TYP.)
Y-STRAINER
BOILER
CIRC.
PRESSURE
RELIEF
VALVE
DOM. HOT WATER
CIRC.
BOILER
INDIRECT
DHW TANK TEMP. /
PRESS. GA.
BOILER
UNION
(TYP.)
DRAIN
DCW
IN
DHW OUT
ANTI-SCALD
MIXING VALVE
FLOW CHECK
VALVE
MULT-TEMP
LOOP CONTROL
LOW VOLTAGE ZONE
LOOP SENSORS
SHIELDED CABLE TO
BOILER CONTROL
ZONE 1 ZONE 2 ADD ZONES AS
REQ.
DIFFERENTIAL
PRESSURE
BYPASS VALVE
THRU
DHW RECIRC. PUMP
CHECK
VALVE
HEAT EXCHANGER
SNOW MELT
MANIFOLD
CONDESATION TO FL. DR.
P-1
P-2
P-3
P-4
P-5
P-6
BT 4X12-40 "BRAZETEK"
ZONE VALVE
ADD ZONES AS
REQ.
3 /4" SCREENED GRAVEL
6 MIL MEMBRANE
4" PERF. PVC
4" NON-PERFORATED (VTR)
SCALE:
MAIN LEVEL MECH PLAN
1
1/4" = 1'-0"
M.1 BOILER MECHANICAL LAYOUT
N.T.S. 2 M.1
MECH. PLANS
7 3 8 S A N D Y L A N E
L O T 5 V A I L / P O T A T O P A T C H S E C O N D F I L I N G
T O W N O F V A I L, C O L O R A D O
S A N D Y L A N E R E S I D E N C E
01 27 16
date
RADON MITIGATION
N.T.S. 3
04/12/16