Loading...
HomeMy WebLinkAboutBlower Door Test.pdf Page 1 of 1 12/4/2016 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com 738 Sandy Lane Blower Door Report Test Date: December 2, 2016 Builder: Holm Construction Contact: Claes Holm Site Address: 738 Sandy Lane, Vail, CO Site Visit By: Megan Gilman Background The project goal is to undergo testing at final construction to determine the final amount of air infiltration and identify any weak areas or difficult details for correction. The project is located in the Town of Vail, where the current code requires an air tightness of 3 ACH50 or less. Active Energies was contracted to perform a final blower door test to determine total air infiltration. Site Observations Construction of the building envelope was nearing completion. All exterior openings were shut and locked and interior doors were open. The ceiling did not have drywall installed and was having tongue and groove wood applied directly to the underside of the vapor barrier. Several exterior doors did not yet have hardware, so their hardware holes were covered with tape. Bath fans were installed, so their backdraft dampers were left to engage during the test. The kitchen range hood was not yet installed, so that duct was covered during the test, since the backdraft damper will be integral to the unit which is not yet installed. The blower door test was performed in lower level exit door. The pressure probe place outside. Blower Door Test The home was depressurized, utilizing blower door testing equipment to a pressure of -50 Pa. At the test pressure, the CFM50 was recorded, in order to determine the ACH50. The blower door air leakage resulted in the following measurements: 2.3 ACH50 Please call with any questions or concerns.