Loading...
HomeMy WebLinkAboutB16-0036_A0.00_1478908517.pdf1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 963 LIONS RIDGE LOOP VAIL, CO 81657 Date 1 A0.00 COVER BREAKAWAY WEST Project Number - 1428 03/04/16 DRB CHANGE TO APPROVED OWNER: BREAKAWAY WEST 963 LIONS RIDGE LOOP VAIL, CO 81657 ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE PIERCE ARCHITECTS 1650 E. VAIL VALLEY DRIVE, C1 VAIL, COLORADO 81657 P: 970.476.6342 F: 970.476.4901 E: bill@vailarchitects.com CONTRACTOR: NEDBO CONSTRUCTION ROLLIE KJESBO P.O. BOX 3419 VAIL, CO 81658 P: 970.845.1001 M: 970.977.0268 E: rollie@nedbo.com STRUCTURAL ENGINEER: BPSE BRIAN PUPPE P: 970.331.6740 E: brian@bpse.net OWNER'S REP OAC MANAGEMENT, INC. ERIK PETERSON, MATT LEWIS 275 MAIN STREET, SUITE #208 EDWARDS, COLORADO 81632 P: 970.390.0164 E: erikpeterson@oacminc.com, mattlewis@oacminc.com ADMINISTRATIVE INFO. BUILDING CODE SUMMARY PROJECT DIRECTORY BUILDING CODE: 2015 IBC CONSTRUCTION TYPE: TYPE V-A DWELLING UNITS: 12 OCCUPANCY TYPE R-2 LEGAL DESCRIPTION OF PROPERTY: Situs Address 000963 LIONS RIDGE LP Parcel Number 2103-014-09-66 Legal Summary DESC: BLDG 1 PK SP 29 Subdivision: BREAKAWAY WEST CONDOS BREAKAWAY WEST PROJECT LOCATION SHEET INDEX - PERMIT SET SHEET # DESCRIPTION BY ISSUE DATE A0.00 COVER PIERCE ARCHITECTS 03/04/16 1 SITE PLAN BRUCE DALTON 03/04/16 A1.01 GARAGE PLAN PIERCE ARCHITECTS 03/04/16 A1.02 FIRST & SECOND FLOOR PLANS PIERCE ARCHITECTS 03/04/16 A1.03 THIRD FLOOR & LOFT PLANS PIERCE ARCHITECTS 03/04/16 A1.08 ROOF PLAN PIERCE ARCHITECTS 03/04/16 A2.01 SOUTH ELEVATION PIERCE ARCHITECTS 03/04/16 A2.02 NORTH ELEVATION PIERCE ARCHITECTS 03/04/16 A2.03 EAST & WEST ELEVATIONS PIERCE ARCHITECTS 04/05/16 A5.00 STAIR DETAILS PIERCE ARCHITECTS 03/04/16 A501.1 WALL SECTIONS PIERCE ARCHITECTS 03/04/16 A501.2 WALL SECTIONS PIERCE ARCHITECTS 03/04/16 A501.3 WINDOW DETAILS PIERCE ARCHITECTS 03/04/16 A501.4 GENERAL NOTES & DETAILS PIERCE ARCHITECTS 03/04/16 A501.5 STAIR DETAILS PIERCE ARCHITECTS 03/04/16 A501.6 DETAILS PIERCE ARCHITECTS 03/04/16 A501.7 DETAILS PIERCE ARCHITECTS 03/04/16 A501.8 WINDOW INSTALLATION PIERCE ARCHITECTS 03/04/16 A9.01 3D VIEWS PIERCE ARCHITECTS 03/04/16 A9.02 3D VIEWS PIERCE ARCHITECTS 03/04/16 A9.03 3D VIEWS PIERCE ARCHITECTS 03/04/16 A9.04 3D VIEWS PIERCE ARCHITECTS 03/04/16 A9.05 PERSPECTIVES PIERCE ARCHITECTS 03/04/16 S1.1 SPECS & SECTIONS BRIAN PUPPE 03/04/16 S2.1 FIRST LVL PLAN BRIAN PUPPE 03/04/16 S2.2 SECOND LVL PLAN BRIAN PUPPE 03/04/16 S2.3 THIRD LVL PLAN BRIAN PUPPE 03/04/16 PER TABLE 503 BASIC ALLOWABLE AREA IS 12000 SQ. FT. PER STORY BUILDING CONTAINS 4092 SQ. FT. OR LESS PER STORY 04/12/16 CODE SUMMARY CHANGE 04/15/16 PERMIT COMMENT REVISIONS THE BREAKAWAY WEST BUILDING 100, 200 WAS BUILT PRIOR TO ESTABLISHED TOWN OF VAIL BUILDING CODES BEING APPLICABLE TO THIS BUILDING. UNDER THE CURRENT INTERNATIONAL BUILDING CODE 2015 (ADOPTED BY THE TOWN OF VAIL), THE BREAKAWAY WEST 100, 200 BUILDING WOULD BE CLASSIFIED AS A TYPE VA CONSTRUCTION TYPE, ALLOWING 3 STORIES IN HEIGHT. THE CURRENT BUILDING IS 4 STORIES. IF BUILDING 100, 200 WERE EQUIPPED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM IT COULD BE CONSTRUCTED 4 STORIES HIGH IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2015. IN LIEU OF INSTALLING AN AUTOMATIC FIRE EXTINGUISHING SYSTEM THE OWNERSHIP OF BREAKAWAY WEST BUILDING 100, 200 ARE INSTALLING SUBSTANTIAL IMPROVEMENTS TO THE EXISTING BUILDING IN ORDER TO INCREASE THE SAFETY OF THE BUILDING: 1. MODIFYING EXISTING STAIRWAYS TO COMPLY WITH RISE/RUN REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2015. 2. REMOVING THE EXISTING COMBUSTIBLE EXTERIOR SIDING AND REPLACING IT WITH NONCOMBUSTIBLE FIBER CEMENT SIDING AND A THREE COAT STUCCO FINISH. 3. INSTALLING EGRESS WINDOWS IN ALL SLEEPING ROOMS 4. INSTALLING 20 MINUTE RATED DOORS WITH SELF-CLOSER AND SMOKE SEAL AT ALL DOOR OPENINGS IN THE STAIRWAY/EXIT PATH. 04/19/16