HomeMy WebLinkAboutB16-0086_A505_1478906386.pdfELEVATION/PLAN/SECTION TITLE
ARCHITECTURAL REFERENCE: DETAIL NO.
ARCHITECTURAL REFERENCE: SHEET NO.
REVISION NO. (SMALL TRIANGLE)
ELEVATION MARK/TITLE
ELEVATION SHEET NUMBER
ELEVATION LOCATION-VIEW POINT
4.01
A
SHEET NUMBER
DETAIL NUMBER
GLAZING INDICATION NUMBER
FIELD APPLIED SEALANT BY GLAZING SUB CONTRACTOR
DIMENSIONAL REFERENCE / ELEVATION
DENOTES BACKER ROD OR CAULK ROPE
NOT NECESSARILY ONE PIECE
DENOTES BLOCKING OR SHIM, NOT CONTINUOUS,
FD
SD
FIELD DRILL
SHOP DRILL
S
WORKING POINT
FASTENER LOCATION
ANCHOR LOCATION
SYMBOLS
DOOR NUMBER
DESCRIPTION
1
NO.
SHEET INDEX
COVER SHEET
3
4
1
1
DETAIL SHEET
ELEVATIONS & PLAN SECTIONS
ELEVATIONS ARE VIEWED FROM
THE INTERIOR, TYPICAL.
1
TYPICAL DETAIL CALLOUT
2 INSTALLATION DETAIL SHEET
EXTRA INFORMATION
PLEASE CHECK SIZES ON DRAWINGS
CAREFULLY.
ANY CHANGES ON WIDTH OR HEIGHT WILL
REQUIRE REVISED DRAWINGS FOR FINAL
APPROVAL.
NANAWALL SYSTEMS IS ONLY A MATERIAL SUPPLIER OF SLIDING & FOLDING PANEL
SYSTEMS. NANAWALL SYSTEMS DOES NOT PROVIDE INSTALLATION AND DOES NOT
DESIGN OR ENGINEER ANY SURROUNDING CONDITIONS AROUND THE OPENINGS TO
WHICH NANAWALL'S SYSTEMS ARE TO BE INSTALLED. ANY SURROUNDING CONDITIONS
SHOWN, IF ANY, IN THESE DRAWINGS ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY
AND WHAT IS SHOWN MAY NOT BE SUITABLE FOR ANY PARTICULAR PROJECT.
AS REGULATIONS GOVERNING THE USE OF GLAZED WINDOWS, DOORS, STOREFRONTS
AND/OR PARTITIONS VARY WIDELY, IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT,
BUILDING OWNER, CONTRACTOR AND/OR CONSUMER (HEREAFTER REFERRED TO AS
"CUSTOMER") TO ENSURE THAT REGULATIONS, INCLUDING FEDERAL, STATE AND LOCAL
ARE ADHERED TO.
PROPER INSTALLATION, OPERATION AND MAINTENANCE OF NANAWALL SYSTEMS
PRODUCTS ARE ESSENTIAL FOR PROPER PERFORMANCE. WRITTEN INSTALLATION,
OPERATION AND MAINTENANCE INSTRUCTIONS ARE AVAILABLE AND PROVIDED TO ALL
CUSTOMERS. IT IS ESSENTIAL THAT THESE INSTRUCTIONS BE READ AND FOLLOWED.
IT IS HIGHLY RECOMMENDED THAT AN EXPERIENCED INSTALLER OF NANAWALL'S
PRODUCTS BE USED FOR RELEVANT ASPECTS OF INSTALLATION. INSTALLATION TO BE
PROVIDED BY OTHERS, INCLUDING BUT NOT LIMITED TO METHOD OF ATTACHMENT,
FASTENER SELECTION AND COMPLETION OF APPROPRIATE WATERPROOFING,
FLASHING AND APPLYING SEALANT OR CAULK AROUND THE PERIMETER OF THE
OPENING, IS THE SOLE RESPONSIBILITY OF THE CUSTOMER.
THE STRUCTURAL INTEGRITY OF HEADER AND/OR OVERHEAD SUPPORT FOR THE
OPENING AND ANY STACKING AREAS, TO BE PROVIDED AND INSTALLED BY OTHERS, IT
IS CRITICAL FOR PROPER PERFORMANCE AND OPERATION. AMONG OTHER FACTORS,
THE DEFLECTION UNDER FULL LIVE AND DEAD LOADS SHOULD BE THE LESSER OF L/720
OF THE SPAN OR 1/4". THE HEADER, SURROUNDING WALLS AND FLOOR MUST ALSO BE
ABLE TO SUPPORT ANY LATERAL LOADS.
WATER RESISTANCE IS RELATIVE. MANY OF NANAWALL'S SYSTEMS WITH CERTAIN
CONFIGURATIONS AND SILLS HAVE BEEN TESTED WITH VARYING DEGREES OF
PERFORMANCE RESULTS. CERTAIN SILLS SUCH AS THE RAISED SILL, IF AVAILABLE FOR
A SYSTEM, PERFORM BETTER AND OTHER SILLS NEED TO BE SITE MODIFIED BY
OTHERS WITH WEEP HOLES AND PROPER DRAINAGE FOR BETTER PERFORMANCE.
NON-STANDARD UNITS SUCH AS SEGMENTED CORNERLESS, ETC. PERFORMANCE
RATING WILL BE LESS THAN A STANDARD UNIT. SEE INFORMATION AVAILABLE IN
NANAWALL'S LITERATURE AND WEBSITE. IT IS THE SOLE RESPONSIBILITY OF THE
CUSTOMER TO DETERMINE THE LEVEL OF PERFORMANCE NEEDED FOR THEIR
SPECIFIC LOCATION AND SITE CONDITIONS AND CHOOSE THE APPROPRIATE NANAWALL
SYSTEM, SIZE AND SILL FOR IT.
ALL DRAWINGS ARE ACCURATE IN METRIC DIMENSIONS. ENGLISH DIMENSIONS SHOWN
ARE ROUNDED TO THE NEAREST 1/16". PRODUCT DRAWINGS SHOULD NOT BE SCALED.
SCALE NOTED ON DRAWINGS ARE BASED ON A 24"X36" PAPER FORMAT
GENERAL NOTES
ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING WELDING
OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS THAT MAY BE HARMFUL TO THE
APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS.
THE ROUGH OPENINGS PROVIDED MUST BE SQUARE AND WITHIN SPECIFIED BUILDING
TOLERANCES.
THESE DRAWINGS REPRESENT NANAWALL'S INTERPRETATION OF THE APPLICATION OF
PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH NANAWALL'S QUOTE
TO CUSTOMER. IT IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED
DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO ACTUAL ARCHITECT INTENT,
INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS.
FINAL APPROVAL BY THE GENERAL CONTRACTOR CONSTITUTES ACCEPTANCE OF ALL
DEVIATIONS TO THE CONTRACT DOCUMENTS MADE BY NANAWALL IN THESE
DRAWINGS.
THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH NANAWALL'S
QUOTATION OR PER AN ACCEPTED CHANGE ORDER AND OTHER APPLICABLE
CONTRACT DOCUMENTS.
NANAWALL WILL ASSUME NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE
OF THESE DRAWINGS BY OTHER TRADES.
NANAWALL DOES NOT PROVIDE NOR TAKE RESPONSIBILITY FOR SIZES, LOCATIONS OR
FREQUENCY OF PERIMETER FASTENERS. VIA OMISSION OF STRUCTURAL
CALCULATIONS, NANAWALL ASSUMES NO RESPONSIBILITY FOR ENGINEERING OF
DETAILED ALUMINUM, WOOD AND GLASS SYSTEMS.
PERIMETER FASTENERS AND SUBSTRATE MUST BE CAPABLE OF WITHSTANDING
REACTION FORCES IMPOSED BY WIND AND/OR DEAD LOAD. NANAWALL WILL NOT BE
LIABLE FOR INSUFFICIENT ANCHORING AND/OR SUBSTRATE.
9.
8.
7.
6.
5.
4.
2.
3.
1.
11.
10.
12.
13.
14.
15. USING EXPANDABLE FOAM WILL VOID NANAWALL'S WARRANTY.
ROUGH OPENING
OVERALL FRAME DIMENSION
SIMULATED DIVIDED LITE
TOP OF HORIZONTAL
=
=
=
=
=
R.O.
T.O.H.
S.D.L.
O.F.D.
DAYLIGHT OPENING
NOT IN CONTRACT
NOT BY NANA WALL
ABOVE FINISHED FLOOR
CENTER OF HORIZONTAL
GENERAL CONTRACTOR
ACCESS CONTROLLED
OPENING DIMENSION
ELEVATION
EL.
=
=
=
=
=
=
N.T.S.
O.D.
N.I.C.
N.B.N.
G.C.
F.F.
F.S.
NOT TO SCALE
FRAME SIZE
FINISHED FLOOR
=
=
=
=
=
=
=
= L
C
D.O.
D.L.O.
DIM.
A.F.F.
C.O.H.
A/C
CENTER LINE
DIMENSION
DOOR OPENING
ABBREVIATIONS
SYSTEM INFORMATION ON THESE DRAWINGS
=
WOOD
PROFILE FINISH SCHEDULE
DESCRIPTION:
LOW PROFILE SADDLE SILL
=
L.P.S.S.
VERIFY IN FIELD
UNIT WIDTH
WINDOW DIMENSION
W.P.
W.D.
WORKING POINT
=
=
=
U.W.
V.I.F.
TO BE DETERMINED
=
T.B.D.
TOP OF FINISHED FLOOR
=
T.O.F.F.
CUSTOMER:CUSTOM HOUSE CONSTRUCTION CORP
NANAWALL PRODUCT DRAWINGS
POWDER COATED ALUMINUM
ANODIZED ALUMINUM
OUTSIDE UNIT DIMENSIONS ARE SHOWN ON THESE
DRAWINGS.
PLEASE ALLOW SHIM SPACE FOR ROUGH OPENING
DIMENSIONS. INSTALLATION DEPENDS ON JOB SITE
CONDITIONS. SEE OWNERS MANUAL FOR
SUGGESTIONS.
CHOOSE FROM OUR 50 STANDARD ECO FRIENDLY
POWDER COATED FINISHES.
~UNIT WEIGHT:
WINDLOAD:
SHGC:
NFRC:
ORDER NUMBER: 19282
PROJECT NAME: PEPI'S BAR REMODEL- VAIL, CO
PLEASE ADVISE IF THERE ARE LIMITATIONS ON MAX. LENGTHS
TO BE SUPPLIED SUCH AS ELEVATOR CAPACITY, ETC
HEAD TRACK AND SILL COMPONENTS MAY BE SHIPPED IN
SEGMENTS THAT WILL BE NEED TO FIELD JOINED
HSW60 SINGLE TRACK SLIDING SYSTEM (ALUMINUM).
TYPE OF GLASS: DOUBLE GLAZED LOW E INSULATED TEMPERED AIR FILLED WITH WARM EDGE
SPACER.
GLASS SPACER BAR FINISH: SILVER GRAY.
HARDWARE ON SLIDING PANELS: TWO POINT LOCKING WITH FLAT HANDLES ON INSIDE OF PANELS
ONLY. (NOTE THAT PANELS ARE OPERABLE FROM THE INSIDE ONLY, AND THAT
THERE ARE NO LATCHES.)
FLAT HANDLE FINISH: STAINLESS STEEL WITH BRUSHED SATIN FINISH.
SILL TYPE: LOW PROFILE SADDLE.(FOR RESISTANCE AGAINST WIND DRIVEN RAIN, DRAIN
CONNECTIONS BY OTHERS NECESSARY)
SILL FINISH: CLEAR ANODIZED.
HEAD TRACK FINISH: CLEAR ANODIZED. (IF COVER INCLUDED, COVER WILL BE THE CLOSEST
POWDER COAT MATCH TO PROFILE FINISH.
CORNER CONNECTOR FINISH (ALL FOUR CORNERS EACH PANEL): CLOSEST POWDER COATED
MATCH TO PROFILE FINISH.
(+456 57$/+66#.
5*''6
14&'4
5%#.'
&4#90 $;
3716'
1(
ÄÄ
065
2,
#22418'&
#22418#.
241,'%6 0#/'
#22418'&
&9)
24+06'& 0#/'
$;
'
\initial_1_1\
A505
01/30/2013
09/20/16