Loading...
HomeMy WebLinkAboutB16-0086_A505_1478906386.pdfELEVATION/PLAN/SECTION TITLE ARCHITECTURAL REFERENCE: DETAIL NO. ARCHITECTURAL REFERENCE: SHEET NO. REVISION NO. (SMALL TRIANGLE) ELEVATION MARK/TITLE ELEVATION SHEET NUMBER ELEVATION LOCATION-VIEW POINT 4.01 A SHEET NUMBER DETAIL NUMBER GLAZING INDICATION NUMBER FIELD APPLIED SEALANT BY GLAZING SUB CONTRACTOR DIMENSIONAL REFERENCE / ELEVATION DENOTES BACKER ROD OR CAULK ROPE NOT NECESSARILY ONE PIECE DENOTES BLOCKING OR SHIM, NOT CONTINUOUS, FD SD FIELD DRILL SHOP DRILL S WORKING POINT FASTENER LOCATION ANCHOR LOCATION SYMBOLS DOOR NUMBER DESCRIPTION 1 NO. SHEET INDEX COVER SHEET 3 4 1 1 DETAIL SHEET ELEVATIONS & PLAN SECTIONS ELEVATIONS ARE VIEWED FROM THE INTERIOR, TYPICAL. 1 TYPICAL DETAIL CALLOUT 2 INSTALLATION DETAIL SHEET EXTRA INFORMATION PLEASE CHECK SIZES ON DRAWINGS CAREFULLY. ANY CHANGES ON WIDTH OR HEIGHT WILL REQUIRE REVISED DRAWINGS FOR FINAL APPROVAL. NANAWALL SYSTEMS IS ONLY A MATERIAL SUPPLIER OF SLIDING & FOLDING PANEL SYSTEMS. NANAWALL SYSTEMS DOES NOT PROVIDE INSTALLATION AND DOES NOT DESIGN OR ENGINEER ANY SURROUNDING CONDITIONS AROUND THE OPENINGS TO WHICH NANAWALL'S SYSTEMS ARE TO BE INSTALLED. ANY SURROUNDING CONDITIONS SHOWN, IF ANY, IN THESE DRAWINGS ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY AND WHAT IS SHOWN MAY NOT BE SUITABLE FOR ANY PARTICULAR PROJECT. AS REGULATIONS GOVERNING THE USE OF GLAZED WINDOWS, DOORS, STOREFRONTS AND/OR PARTITIONS VARY WIDELY, IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT, BUILDING OWNER, CONTRACTOR AND/OR CONSUMER (HEREAFTER REFERRED TO AS "CUSTOMER") TO ENSURE THAT REGULATIONS, INCLUDING FEDERAL, STATE AND LOCAL ARE ADHERED TO. PROPER INSTALLATION, OPERATION AND MAINTENANCE OF NANAWALL SYSTEMS PRODUCTS ARE ESSENTIAL FOR PROPER PERFORMANCE. WRITTEN INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ARE AVAILABLE AND PROVIDED TO ALL CUSTOMERS. IT IS ESSENTIAL THAT THESE INSTRUCTIONS BE READ AND FOLLOWED. IT IS HIGHLY RECOMMENDED THAT AN EXPERIENCED INSTALLER OF NANAWALL'S PRODUCTS BE USED FOR RELEVANT ASPECTS OF INSTALLATION. INSTALLATION TO BE PROVIDED BY OTHERS, INCLUDING BUT NOT LIMITED TO METHOD OF ATTACHMENT, FASTENER SELECTION AND COMPLETION OF APPROPRIATE WATERPROOFING, FLASHING AND APPLYING SEALANT OR CAULK AROUND THE PERIMETER OF THE OPENING, IS THE SOLE RESPONSIBILITY OF THE CUSTOMER. THE STRUCTURAL INTEGRITY OF HEADER AND/OR OVERHEAD SUPPORT FOR THE OPENING AND ANY STACKING AREAS, TO BE PROVIDED AND INSTALLED BY OTHERS, IT IS CRITICAL FOR PROPER PERFORMANCE AND OPERATION. AMONG OTHER FACTORS, THE DEFLECTION UNDER FULL LIVE AND DEAD LOADS SHOULD BE THE LESSER OF L/720 OF THE SPAN OR 1/4". THE HEADER, SURROUNDING WALLS AND FLOOR MUST ALSO BE ABLE TO SUPPORT ANY LATERAL LOADS. WATER RESISTANCE IS RELATIVE. MANY OF NANAWALL'S SYSTEMS WITH CERTAIN CONFIGURATIONS AND SILLS HAVE BEEN TESTED WITH VARYING DEGREES OF PERFORMANCE RESULTS. CERTAIN SILLS SUCH AS THE RAISED SILL, IF AVAILABLE FOR A SYSTEM, PERFORM BETTER AND OTHER SILLS NEED TO BE SITE MODIFIED BY OTHERS WITH WEEP HOLES AND PROPER DRAINAGE FOR BETTER PERFORMANCE. NON-STANDARD UNITS SUCH AS SEGMENTED CORNERLESS, ETC. PERFORMANCE RATING WILL BE LESS THAN A STANDARD UNIT. SEE INFORMATION AVAILABLE IN NANAWALL'S LITERATURE AND WEBSITE. IT IS THE SOLE RESPONSIBILITY OF THE CUSTOMER TO DETERMINE THE LEVEL OF PERFORMANCE NEEDED FOR THEIR SPECIFIC LOCATION AND SITE CONDITIONS AND CHOOSE THE APPROPRIATE NANAWALL SYSTEM, SIZE AND SILL FOR IT. ALL DRAWINGS ARE ACCURATE IN METRIC DIMENSIONS. ENGLISH DIMENSIONS SHOWN ARE ROUNDED TO THE NEAREST 1/16". PRODUCT DRAWINGS SHOULD NOT BE SCALED. SCALE NOTED ON DRAWINGS ARE BASED ON A 24"X36" PAPER FORMAT GENERAL NOTES ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING WELDING OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS. THE ROUGH OPENINGS PROVIDED MUST BE SQUARE AND WITHIN SPECIFIED BUILDING TOLERANCES. THESE DRAWINGS REPRESENT NANAWALL'S INTERPRETATION OF THE APPLICATION OF PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH NANAWALL'S QUOTE TO CUSTOMER. IT IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO ACTUAL ARCHITECT INTENT, INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS. FINAL APPROVAL BY THE GENERAL CONTRACTOR CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE BY NANAWALL IN THESE DRAWINGS. THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH NANAWALL'S QUOTATION OR PER AN ACCEPTED CHANGE ORDER AND OTHER APPLICABLE CONTRACT DOCUMENTS. NANAWALL WILL ASSUME NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESE DRAWINGS BY OTHER TRADES. NANAWALL DOES NOT PROVIDE NOR TAKE RESPONSIBILITY FOR SIZES, LOCATIONS OR FREQUENCY OF PERIMETER FASTENERS. VIA OMISSION OF STRUCTURAL CALCULATIONS, NANAWALL ASSUMES NO RESPONSIBILITY FOR ENGINEERING OF DETAILED ALUMINUM, WOOD AND GLASS SYSTEMS. PERIMETER FASTENERS AND SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY WIND AND/OR DEAD LOAD. NANAWALL WILL NOT BE LIABLE FOR INSUFFICIENT ANCHORING AND/OR SUBSTRATE. 9. 8. 7. 6. 5. 4. 2. 3. 1. 11. 10. 12. 13. 14. 15. USING EXPANDABLE FOAM WILL VOID NANAWALL'S WARRANTY. ROUGH OPENING OVERALL FRAME DIMENSION SIMULATED DIVIDED LITE TOP OF HORIZONTAL = = = = = R.O. T.O.H. S.D.L. O.F.D. DAYLIGHT OPENING NOT IN CONTRACT NOT BY NANA WALL ABOVE FINISHED FLOOR CENTER OF HORIZONTAL GENERAL CONTRACTOR ACCESS CONTROLLED OPENING DIMENSION ELEVATION EL. = = = = = = N.T.S. O.D. N.I.C. N.B.N. G.C. F.F. F.S. NOT TO SCALE FRAME SIZE FINISHED FLOOR = = = = = = = = L C D.O. D.L.O. DIM. A.F.F. C.O.H. A/C CENTER LINE DIMENSION DOOR OPENING ABBREVIATIONS SYSTEM INFORMATION ON THESE DRAWINGS = WOOD PROFILE FINISH SCHEDULE DESCRIPTION: LOW PROFILE SADDLE SILL = L.P.S.S. VERIFY IN FIELD UNIT WIDTH WINDOW DIMENSION W.P. W.D. WORKING POINT = = = U.W. V.I.F. TO BE DETERMINED = T.B.D. TOP OF FINISHED FLOOR = T.O.F.F. CUSTOMER:CUSTOM HOUSE CONSTRUCTION CORP NANAWALL PRODUCT DRAWINGS POWDER COATED ALUMINUM ANODIZED ALUMINUM OUTSIDE UNIT DIMENSIONS ARE SHOWN ON THESE DRAWINGS. PLEASE ALLOW SHIM SPACE FOR ROUGH OPENING DIMENSIONS. INSTALLATION DEPENDS ON JOB SITE CONDITIONS. SEE OWNERS MANUAL FOR SUGGESTIONS. CHOOSE FROM OUR 50 STANDARD ECO FRIENDLY POWDER COATED FINISHES. ~UNIT WEIGHT: WINDLOAD: SHGC: NFRC: ORDER NUMBER: 19282 PROJECT NAME: PEPI'S BAR REMODEL- VAIL, CO PLEASE ADVISE IF THERE ARE LIMITATIONS ON MAX. LENGTHS TO BE SUPPLIED SUCH AS ELEVATOR CAPACITY, ETC HEAD TRACK AND SILL COMPONENTS MAY BE SHIPPED IN SEGMENTS THAT WILL BE NEED TO FIELD JOINED HSW60 SINGLE TRACK SLIDING SYSTEM (ALUMINUM). TYPE OF GLASS: DOUBLE GLAZED LOW E INSULATED TEMPERED AIR FILLED WITH WARM EDGE SPACER. GLASS SPACER BAR FINISH: SILVER GRAY. HARDWARE ON SLIDING PANELS: TWO POINT LOCKING WITH FLAT HANDLES ON INSIDE OF PANELS ONLY. (NOTE THAT PANELS ARE OPERABLE FROM THE INSIDE ONLY, AND THAT THERE ARE NO LATCHES.) FLAT HANDLE FINISH: STAINLESS STEEL WITH BRUSHED SATIN FINISH. SILL TYPE: LOW PROFILE SADDLE.(FOR RESISTANCE AGAINST WIND DRIVEN RAIN, DRAIN CONNECTIONS BY OTHERS NECESSARY) SILL FINISH: CLEAR ANODIZED. HEAD TRACK FINISH: CLEAR ANODIZED. (IF COVER INCLUDED, COVER WILL BE THE CLOSEST POWDER COAT MATCH TO PROFILE FINISH. CORNER CONNECTOR FINISH (ALL FOUR CORNERS EACH PANEL): CLOSEST POWDER COATED MATCH TO PROFILE FINISH. (+456 57$/+66#.  5*''6 14&'4 5%#.' &4#90 $; 3716' 1(   ÄÄ  065 2, #22418'& #22418#. 241,'%6 0#/' #22418'& &9)  24+06'& 0#/' $; &#6' \initial_1_1\ A505 01/30/2013 09/20/16