Loading...
HomeMy WebLinkAboutCOMcheck.pdf 1141 COMcheck Software Version 4.0.1 Interior Lighting Compliance Certificate Project Information Energy Code: 2012 IECC Project Title: Pepi's Bar Remodel Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 231 East Gore Creek Drive AEC Vail, CO 81657 Avon,CO 81620 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts 1 ft2 (B X C) 1-DINING Common Space Types:Barllounge/leisure dining) '1943 1 .39 2720 Total Allowed Watts= 2720 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp l Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. DINING (Common Space Types:Bar/lounge/leisure dining 1943 sq.ft.) LED 1:A:RECESSED DL 4":LED PAR 15W: 1 26 15 390 LED 2:B:BAR PENDENT:LED A Lamp 12W: 1 6 20 120 LED 3:C:RESTROOM SCONCE:LED A Lamp 12W: 1 4 20 80 LED 5: E:RECESSED DL 5":LED PAR 11W: 1 8 11 88 LED 6:K:KABLE LIGHT SYSTEM:LED MR 7W: 1 50 8 375 LED T M:LED STRIP LIGHTING:LED Linear 10W: 1 24 12 288 LED 8:FIL:FAN/LIGHT COMBO:LED Linear BW: 1 3 8 24 Total Proposed Watts= 1365 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement; The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.1 and to comply with the mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 1 of 6 rftCOMcheck Software Version 4.0.1 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 2012 IECC Plan Review Complies? Comments/Assumptions C103.2 Plans,specifications, and/or ❑Complies [PR4]' calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed, Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 2 of 6 201.2 IECC Rough-In Electrical Inspection Complies? Comments/Assumptions • C405.2,2, :Automatic controls to shut off all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ['Not Observable ElNot Applicable C405.2.1. Independent lighting controls installed ❑Complies 1 per approved lighting plans and all ❑Does Not [EL23]2 manual controls readily accessible and ['Not Observable visible to occupants. ❑Not Applicable C405.2.1. Lighting controls installed to uniformly ❑Complies 2 reduce the lighting load by at least ElDoes Not [EL15]' 50%. [Not Observable ❑Not Applicable C405.2.2. Daylight zones provided with ❑Complies 3 individual controls that control the ElDoes Not IEL16]2 lights independent of general area lighting. [Not Observable ❑Not Applicable C405.2.3 Sleeping units have at least one ❑Complies (EL17]3 master switch at the main entry door ElDoes Not that controls wired luminaires and • switched receptacles. [Not Observable ❑Not Applicable • C405.2.2. Occupancy sensors installed in ;❑Complies 2 required spaces. •❑Does Not [E1_18]1 pilot Observable ❑Nat Applicable C405.2.2. Primary sidelighted areas are ❑Complies 3 equipped with required lighting ElDoes Not [EL20]1 controls. [Not Observable ❑Nat Applicable C405.2.2. Enclosed spaces with daylight area ;❑Complies 3 under skylights and rooftop monitors ❑Does Not [EL21]' are equipped with required lighting [Not Observable controls. ❑Not Applicable C405.2.3 Separate lighting control devices for ❑Complies [EL4]' specific uses installed per approved ❑Does Not lighting plans. [Not Observable ❑Not Applicable C405.3 Fluorescent luminaires with odd ❑Complies [E1_19]3 numbered lamp configurations that ElDoes Nat are with 10 feet center to center(if recess mounted) or are within 1 foot [Not Observable edge to edge(if pendant or surface ❑Not Applicable mounted)shall be tandem wired. C405.4 Exit signs do not exceed 5 watts per ElComplies (EL611 face. ElDoes Nat [Not Observable ❑Not Applicable C405.2.3 Additional interior lighting power ❑Complies (EL8)1 allowed for special functions per the ElDoes Nat approved lighting plans and is automatically controlled and ❑Not Observable separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 15-1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 3 of 6 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename- P:\Current Projects\16001.0❑-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 4 of 6 2012IECC Final Inspection Complies? Comments/Assumptions • C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 30 days ❑Does Not (FI16]3 of system acceptance. ['Not Observable ElNot Applicable C303.3,C4 Furnished O&M instructions for ;❑Complies 08.2.5.2 systems and equipment to the :❑Does Not [F117]3 building owner or designated representative. :Not Observable ❑Not Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting [Not Observable plans,demonstrating proposed watts are less than or equal to allowed ElNot Applicable watts. C408.3 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. :Not Observable ElNot Applicable C406 Efficient HVAC performance, efficient ❑Complies [F134]1 lighting system,or on-site supply of ❑Does Not renewable energy consistent with what is shown the approved plans. ['Not Observable ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 5 of 6 Project Title: Pepi's Bar Remodel Report date: 04/05/16 Data filename- P:\Current Projects\16001.0❑-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 6 of 6