HomeMy WebLinkAboutCOMcheck.pdf 1141 COMcheck Software Version 4.0.1
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2012 IECC
Project Title: Pepi's Bar Remodel
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
231 East Gore Creek Drive AEC
Vail, CO 81657 Avon,CO 81620
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts 1 ft2 (B X C)
1-DINING Common Space Types:Barllounge/leisure dining) '1943 1 .39 2720
Total Allowed Watts= 2720
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp l Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
DINING (Common Space Types:Bar/lounge/leisure dining 1943 sq.ft.)
LED 1:A:RECESSED DL 4":LED PAR 15W: 1 26 15 390
LED 2:B:BAR PENDENT:LED A Lamp 12W: 1 6 20 120
LED 3:C:RESTROOM SCONCE:LED A Lamp 12W: 1 4 20 80
LED 5: E:RECESSED DL 5":LED PAR 11W: 1 8 11 88
LED 6:K:KABLE LIGHT SYSTEM:LED MR 7W: 1 50 8 375
LED T M:LED STRIP LIGHTING:LED Linear 10W: 1 24 12 288
LED 8:FIL:FAN/LIGHT COMBO:LED Linear BW: 1 3 8 24
Total Proposed Watts= 1365
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement; The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.1 and to comply with the mandatory
requirements listed in the Inspection Checklist.
Name-Title Signature Date
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 1 of 6
rftCOMcheck Software Version 4.0.1
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
2012 IECC Plan Review Complies? Comments/Assumptions
C103.2 Plans,specifications, and/or ❑Complies
[PR4]' calculations provide all information ❑Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed, Information
provided should include interior
lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 2 of 6
201.2 IECC Rough-In Electrical Inspection Complies? Comments/Assumptions
•
C405.2,2, :Automatic controls to shut off all ❑Complies
1 building lighting installed in all ❑Does Not
[EL22]2 buildings.
['Not Observable
ElNot Applicable
C405.2.1. Independent lighting controls installed ❑Complies
1 per approved lighting plans and all ❑Does Not
[EL23]2 manual controls readily accessible and
['Not Observable
visible to occupants.
❑Not Applicable
C405.2.1. Lighting controls installed to uniformly ❑Complies
2 reduce the lighting load by at least ElDoes Not
[EL15]' 50%.
[Not Observable
❑Not Applicable
C405.2.2. Daylight zones provided with ❑Complies
3 individual controls that control the ElDoes Not
IEL16]2 lights independent of general area
lighting. [Not Observable
❑Not Applicable
C405.2.3 Sleeping units have at least one ❑Complies
(EL17]3 master switch at the main entry door ElDoes Not
that controls wired luminaires and •
switched receptacles. [Not Observable
❑Not Applicable
•
C405.2.2. Occupancy sensors installed in ;❑Complies
2 required spaces. •❑Does Not
[E1_18]1
pilot Observable
❑Nat Applicable
C405.2.2. Primary sidelighted areas are ❑Complies
3 equipped with required lighting ElDoes Not
[EL20]1 controls.
[Not Observable
❑Nat Applicable
C405.2.2. Enclosed spaces with daylight area ;❑Complies
3 under skylights and rooftop monitors ❑Does Not
[EL21]' are equipped with required lighting
[Not Observable
controls.
❑Not Applicable
C405.2.3 Separate lighting control devices for ❑Complies
[EL4]' specific uses installed per approved ❑Does Not
lighting plans.
[Not Observable
❑Not Applicable
C405.3 Fluorescent luminaires with odd ❑Complies
[E1_19]3 numbered lamp configurations that ElDoes Nat
are with 10 feet center to center(if
recess mounted) or are within 1 foot [Not Observable
edge to edge(if pendant or surface ❑Not Applicable
mounted)shall be tandem wired.
C405.4 Exit signs do not exceed 5 watts per ElComplies
(EL611 face. ElDoes Nat
[Not Observable
❑Not Applicable
C405.2.3 Additional interior lighting power ❑Complies
(EL8)1 allowed for special functions per the ElDoes Nat
approved lighting plans and is
automatically controlled and ❑Not Observable
separated from general lighting. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 15-1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 3 of 6
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename- P:\Current Projects\16001.0❑-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 4 of 6
2012IECC Final Inspection Complies? Comments/Assumptions
•
C408.2.5. Furnished as-built drawings for ❑Complies
1 electric power systems within 30 days ❑Does Not
(FI16]3 of system acceptance.
['Not Observable
ElNot Applicable
C303.3,C4 Furnished O&M instructions for ;❑Complies
08.2.5.2 systems and equipment to the :❑Does Not
[F117]3 building owner or designated
representative.
:Not Observable
❑Not Applicable
C405.5.2 Interior installed lamp and fixture ❑Complies See the interior Lighting fixture schedule for values.
[F118]1 lighting power is consistent with what ❑Does Not
is shown on the approved lighting
[Not Observable
plans,demonstrating proposed watts
are less than or equal to allowed ElNot Applicable
watts.
C408.3 Lighting systems have been tested to ❑Complies
[F133]1 ensure proper calibration, adjustment, ❑Does Not
programming, and operation.
:Not Observable
ElNot Applicable
C406 Efficient HVAC performance, efficient ❑Complies
[F134]1 lighting system,or on-site supply of ❑Does Not
renewable energy consistent with
what is shown the approved plans. ['Not Observable
ElNot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename: P:\Current Projects\16001.00-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 5 of 6
Project Title: Pepi's Bar Remodel Report date: 04/05/16
Data filename- P:\Current Projects\16001.0❑-TOV Fire Station #1 Renovation\Calculations\COMcheck\Pepi's.c Page 6 of 6