HomeMy WebLinkAboutB16-0117_A1-01_1478904918.pdfDN
DN
A2-10/ 02
8' - 7"
BOOT LAB
DEMO CENTER
A2-10/ 05
A2-10/ 06
A2-10/ 03
A2-10/ 01
A2-10/ 04
RESURFACED
DISPLAY WINDOW
PLATFORM WITH
LVT FINISH
PROVIDE METAL STRAPPING
AROUND EXISTING BUILDING
ELEMENTS THAT ARE TO
HAVE SLATWALL SYSTEM
UNLESS EXISTING
SUBSTRATE IS IN
SERVICABLE CONDITION
PROVIDE NEW 2" XPS
INSULATION GLUE
INTO PLACE AND
SEALED WITH SPRAY
FOAM UNDERNEATH
ALL EXTERIOR BAY
WINDOW ASSEMBLIES
RE-PAINT ALL
EXPOSED OR PAINTED
WOOD WITH
EXTERIOR GRADE
LATEX PAINT, RE-
FASTEN TRIM AS
NEEDED, TYP. USE
WOOD FILLER AS
NEEDED, TYP
PROVIDE METAL STRAPPING
ON EXISTING WALLS THAT
ARE TO HAVE SLATWALL
SYSTEM UNLESS EXISTING
SUBSTRATE IS IN
SERVICABLE CONDITION
PROVIDE NEW 11" RETROFIT
METAL STAIR TREADS AT ALL
TREADS TO BASEMENT LEVEL
(NOTE THAT STAIR TURNS
CORNER AND HAS 5 MORE
TREADS THAN SHOWN) - INFILL
REMAINING 3.25" WITH RUBBER
FLOOR 1
NEW STANLEY
DURAGLIDE 2000
AUTOMATIC
SLIDING DOOR
MECH
SHAFT
PROVIDE ALLOWANCE:
NEW CLEAR CEDAR
WRAPPED CASHIER
DESK WITH SOLID
SURFACE COUNTER-TOP
AND TRANSACTION
COUNTER
EXISTING DOOR TO REMAIN,
REPLACE GLASS
PROVIDE METAL
STRAPPING AROUND
EXISTING BUILDING
ELEMENTS THAT ARE TO
HAVE SLATWALL SYSTEM
UNLESS EXISTING
SUBSTRATE IS IN
SERVICABLE CONDITION
APPROXIMATELY 350 SF OF FLOOR THAT
REQUIRES GYPCRETE LEVELING
NEW WOOD RAINSCREEN WALL OVER
2x4 FRAMING AND SHEATHING TO
COVER NEW STEEL COLUMNS, SEE
EXTERIOR ELEVATIONS
ALTERNATE #3
COORDINATE WITH
MECHANICAL SUB-
CONTRACTOR TO
RELOCATE ALL
HYRDRONIC
BASEBOARD HEAT TO BE
CLOSER TO PERIMETER
WALLS / WINDOWS
COORDINATE THIS
DOOR WITH EXISTING
OPENING AND VERIFY
IN FIELD
3' - 0"
ALTERNATE #2
REMOVE CMU COLUMN
AND REPLACE WITH 4X4
HSS, RE: STRUCTURAL
DRAWINGS
6' - 0"
DASHED LINE INDICATES TO
PROVIDE PAINTED 3/4"
PLYWOOD AROUND
PERIMETER OF STORAGE
AREAS AND NEW WALL TO
UNDERSIDE OF JOISTS ABOVE
- BRACE AS REQUIRED TO
UNDERSIDE OF DECK
STORAGE
REMOVE ALL DEAD
SPACE AT EXTERIOR
WALLS FOR SLATWALL
SYSTEM, TYPICAL
REMOVE ALL DEAD
SPACE AT EXTERIOR
WALLS FOR
SLATWALL SYSTEM,
TYPICAL
05
A7-01
ALTERNATE #3 COORDINATE
WITH MECHANICAL SUB-
CONTRACTOR TO RELOCATE
ALL HYRDRONIC BASEBOARD
HEAT TO BE CLOSER TO
PERIMETER WALLS /
WINDOWS
ADA FITTING 2
FRAMED MIRROR WITH
LED TAPE LIGHTING
AROUND THE PERIMETER
RE: 02/A7-02
RESURFACED
DISPLAY WINDOW
PLATFORM WITH
LVT FINISH
04
A7-02
A7-02
02
MIRROR
NO SLATWALL OR
MIRROR ON SHORT
ENDS, SLATWALL ON
LONG ENDS.
MIRROR
MIRROR
ON 3-SIDES
RESURFACED
DISPLAY WINDOW
PLATFORM WITH
LVT FINISH
07
A7-02
A3-01/ 01
04
A7-02
NEW WOOD RAINSCREEN WALL OVER
EXISTING STUCCO WITH 2x4 FRAMING AND
SHEATHING TO COVER NEW STEEL
COLUMNS, SEE EXTERIOR ELEVATIONS
A7-01
06
A7-01
07
A7-01
09
WHITE WASH OAK
PANELS OF DISPLAY
WINDOWS
NEW BRAKE-FORMED
METAL DOWNSPOUT,
PAINT TO MATCH
COPPER FLASHING
NEW CONCEALED DOWNSPOUT WITH
BRAKE-FORMED METAL EXTERIOR SPOUT,
PAINT TO MATCH COPPER FLASHING
REPLACE GLASS WITH
SOLARBAN 60 AND FIX
CRANK OPERATORS
ALTERNATE #3
COORDINATE WITH MECANICAL
SUB-CONTRACTOR TO
RELOCATE ALL HYDRONIC
BASEBOARD HEAD TO BE
CLOSE TO WALLS/WINDOWS
ROUTE EXHAUST FAN
TO EXTERIOR
FITTING 3
WALL DOES NOT
NEED BLOCKING,
JUST TAPED DRYWALL
METAL FRAMED
WALLS WITH 1
LAYER DRYWALL.
ADD POWER/DATA
FITTING 1
MIN. 20" DEEP ADA
BENCH WITH MIN.
HEIGHT OF 17" AND
MAX. HEIGHT OF 19".
MIN. 42" LENGTH.
WALL WITH ACCESS
PANEL FOR DISPLAY
CASE - CONFIRM WITH
OWNER
01
02
NOTE: MINIMUM REQUIRED
32" CLEAR WHEN OPEN IN
ORDER TO MEET ADA
REQUIREMENTS FOR
PASSAGE
03
SALES COUNTER BY
OTHERS TO MEET ADA
REQUIREMENTS
SEE DOOR SCHEDULE
FOR ALL NEW WOOD
DOORS AND HOLLOW
METAL FRAMES
PROVIDE REQUIRED
60" DIAMETER CLEAR
CIRCULAR TURNING
SPACE
SALES COUNTER BY
OTHERS TO MEET ADA
REQUIREMENTS
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE PROVIDED FROM FINISH EDGE TO
FINISHED EDGE
2. HEAVY LINES ALONG PERIMETER WALLS INDICATES
REQUIREMENT FOR 18 GAGE METAL STRAPPING TO SUPPORT
SLAT WALL DISPLAY ASSEMBLIES RE: DETAILS
6" METAL STRAPPING TO BE INSTALLED, AT 2'-6", 5'-6", 6'-6" AND
7'-6" O.C. AFF
3. SLAT WALL TO BE OWNER PROVIDED, CONTRACTER
INSTALLED FROM 2' AFF TO 8' AFF, 24 FASTENERS MINIMUN
PER 4'X8' SHEET OF SLAT WALL AND CONSTRUCTION
ADHESIVE
4. ANY EXPOSED WALL TO BE PAINTED DARK GRAY FROM TOP OF
SLATWALL SYSTEM TO BOTTOM OF A.C.T. SYSTEM
ALTERNATES
#1. ALL EXTERIOR WORK INCLUDING CANOPIES, CEDAR SIDING AND
TRIM, EXTERIOR LIGHTING, REMOVAL OF PHONE BOOTHS AND
PLANTERS WITH REPATCHING OF STUCCO, AND REPAINTING
#2. REMOVAL OF CMU COLUMN INDICATED ON PLANS
#3. RELOCATE HYDRONIC BASEBOARD HEAT TO BE AS CLOSE TO
THE PERIMETER WALLS AS POSSIBLE
SLATWALL EXPOSED STANDARDS
EVERY 4'-0" O.C.
CUT AND MOUNT SLATWALL IN
BETWEEN STARDARDS, CONFIRM
STANDARD LOCATIONS WITH
OWNER PRIOR TO INSTALL
SLATWALL SYSTEM
LEGEND
PAINTED 3/4" PLYWOOD
PROJECT NUMBER
ISSUE DATE
GENERAL CONTRACTOR
GE JOHNSON
40800 HIGHWAY 6, SUITE 8
P.O. BOX 8808
AVON, CO 81620
CONTACT: JOHN HALLORAN 970.471.6048
710 W. COLFAX; DENVER, C0 80204
STRUCTURAL
MONROE & NEWELL
70 BENCHMARK RD. STE. 204
P.O. BOX 1587
AVON, CO 81620
CONTACT: HANNES SPAEH 970.949.7768
ELECTRICAL & LIGHTING DESIGN
ARCHITECTURAL ENGINEERING CONSULTANTS
40801 US HWY 6 & 24, STE. 214
P.O. BOX 8489
AVON, CO 81620
CONTACT: STANTON HUMPHRIES 970.748.8520
REVISION
SHEET TITLE
SHEET NO.
CHRISTY
SPORTS LLC
293 BRIDGE
STREET
VAIL,
COLORADO
81657
TOWN
OF VAIL
STAMP
A1-01
LEVEL 1 - FLOOR PLAN
15020
CHRISTY
SPORTS
VAIL
MARCH 18, 2016
1/4" = 1'-0"
01 LEVEL 1
No. Description Date
03/18/2016
05/27/16