Loading...
HomeMy WebLinkAboutB16-0117_A1-01_1478904918.pdfDN DN A2-10/ 02 8' - 7" BOOT LAB DEMO CENTER A2-10/ 05 A2-10/ 06 A2-10/ 03 A2-10/ 01 A2-10/ 04 RESURFACED DISPLAY WINDOW PLATFORM WITH LVT FINISH PROVIDE METAL STRAPPING AROUND EXISTING BUILDING ELEMENTS THAT ARE TO HAVE SLATWALL SYSTEM UNLESS EXISTING SUBSTRATE IS IN SERVICABLE CONDITION PROVIDE NEW 2" XPS INSULATION GLUE INTO PLACE AND SEALED WITH SPRAY FOAM UNDERNEATH ALL EXTERIOR BAY WINDOW ASSEMBLIES RE-PAINT ALL EXPOSED OR PAINTED WOOD WITH EXTERIOR GRADE LATEX PAINT, RE- FASTEN TRIM AS NEEDED, TYP. USE WOOD FILLER AS NEEDED, TYP PROVIDE METAL STRAPPING ON EXISTING WALLS THAT ARE TO HAVE SLATWALL SYSTEM UNLESS EXISTING SUBSTRATE IS IN SERVICABLE CONDITION PROVIDE NEW 11" RETROFIT METAL STAIR TREADS AT ALL TREADS TO BASEMENT LEVEL (NOTE THAT STAIR TURNS CORNER AND HAS 5 MORE TREADS THAN SHOWN) - INFILL REMAINING 3.25" WITH RUBBER FLOOR 1 NEW STANLEY DURAGLIDE 2000 AUTOMATIC SLIDING DOOR MECH SHAFT PROVIDE ALLOWANCE: NEW CLEAR CEDAR WRAPPED CASHIER DESK WITH SOLID SURFACE COUNTER-TOP AND TRANSACTION COUNTER EXISTING DOOR TO REMAIN, REPLACE GLASS PROVIDE METAL STRAPPING AROUND EXISTING BUILDING ELEMENTS THAT ARE TO HAVE SLATWALL SYSTEM UNLESS EXISTING SUBSTRATE IS IN SERVICABLE CONDITION APPROXIMATELY 350 SF OF FLOOR THAT REQUIRES GYPCRETE LEVELING NEW WOOD RAINSCREEN WALL OVER 2x4 FRAMING AND SHEATHING TO COVER NEW STEEL COLUMNS, SEE EXTERIOR ELEVATIONS ALTERNATE #3 COORDINATE WITH MECHANICAL SUB- CONTRACTOR TO RELOCATE ALL HYRDRONIC BASEBOARD HEAT TO BE CLOSER TO PERIMETER WALLS / WINDOWS COORDINATE THIS DOOR WITH EXISTING OPENING AND VERIFY IN FIELD 3' - 0" ALTERNATE #2 REMOVE CMU COLUMN AND REPLACE WITH 4X4 HSS, RE: STRUCTURAL DRAWINGS 6' - 0" DASHED LINE INDICATES TO PROVIDE PAINTED 3/4" PLYWOOD AROUND PERIMETER OF STORAGE AREAS AND NEW WALL TO UNDERSIDE OF JOISTS ABOVE - BRACE AS REQUIRED TO UNDERSIDE OF DECK STORAGE REMOVE ALL DEAD SPACE AT EXTERIOR WALLS FOR SLATWALL SYSTEM, TYPICAL REMOVE ALL DEAD SPACE AT EXTERIOR WALLS FOR SLATWALL SYSTEM, TYPICAL 05 A7-01 ALTERNATE #3 COORDINATE WITH MECHANICAL SUB- CONTRACTOR TO RELOCATE ALL HYRDRONIC BASEBOARD HEAT TO BE CLOSER TO PERIMETER WALLS / WINDOWS ADA FITTING 2 FRAMED MIRROR WITH LED TAPE LIGHTING AROUND THE PERIMETER RE: 02/A7-02 RESURFACED DISPLAY WINDOW PLATFORM WITH LVT FINISH 04 A7-02 A7-02 02 MIRROR NO SLATWALL OR MIRROR ON SHORT ENDS, SLATWALL ON LONG ENDS. MIRROR MIRROR ON 3-SIDES RESURFACED DISPLAY WINDOW PLATFORM WITH LVT FINISH 07 A7-02 A3-01/ 01 04 A7-02 NEW WOOD RAINSCREEN WALL OVER EXISTING STUCCO WITH 2x4 FRAMING AND SHEATHING TO COVER NEW STEEL COLUMNS, SEE EXTERIOR ELEVATIONS A7-01 06 A7-01 07 A7-01 09 WHITE WASH OAK PANELS OF DISPLAY WINDOWS NEW BRAKE-FORMED METAL DOWNSPOUT, PAINT TO MATCH COPPER FLASHING NEW CONCEALED DOWNSPOUT WITH BRAKE-FORMED METAL EXTERIOR SPOUT, PAINT TO MATCH COPPER FLASHING REPLACE GLASS WITH SOLARBAN 60 AND FIX CRANK OPERATORS ALTERNATE #3 COORDINATE WITH MECANICAL SUB-CONTRACTOR TO RELOCATE ALL HYDRONIC BASEBOARD HEAD TO BE CLOSE TO WALLS/WINDOWS ROUTE EXHAUST FAN TO EXTERIOR FITTING 3 WALL DOES NOT NEED BLOCKING, JUST TAPED DRYWALL METAL FRAMED WALLS WITH 1 LAYER DRYWALL. ADD POWER/DATA FITTING 1 MIN. 20" DEEP ADA BENCH WITH MIN. HEIGHT OF 17" AND MAX. HEIGHT OF 19". MIN. 42" LENGTH. WALL WITH ACCESS PANEL FOR DISPLAY CASE - CONFIRM WITH OWNER 01 02 NOTE: MINIMUM REQUIRED 32" CLEAR WHEN OPEN IN ORDER TO MEET ADA REQUIREMENTS FOR PASSAGE 03 SALES COUNTER BY OTHERS TO MEET ADA REQUIREMENTS SEE DOOR SCHEDULE FOR ALL NEW WOOD DOORS AND HOLLOW METAL FRAMES PROVIDE REQUIRED 60" DIAMETER CLEAR CIRCULAR TURNING SPACE SALES COUNTER BY OTHERS TO MEET ADA REQUIREMENTS FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE PROVIDED FROM FINISH EDGE TO FINISHED EDGE 2. HEAVY LINES ALONG PERIMETER WALLS INDICATES REQUIREMENT FOR 18 GAGE METAL STRAPPING TO SUPPORT SLAT WALL DISPLAY ASSEMBLIES RE: DETAILS 6" METAL STRAPPING TO BE INSTALLED, AT 2'-6", 5'-6", 6'-6" AND 7'-6" O.C. AFF 3. SLAT WALL TO BE OWNER PROVIDED, CONTRACTER INSTALLED FROM 2' AFF TO 8' AFF, 24 FASTENERS MINIMUN PER 4'X8' SHEET OF SLAT WALL AND CONSTRUCTION ADHESIVE 4. ANY EXPOSED WALL TO BE PAINTED DARK GRAY FROM TOP OF SLATWALL SYSTEM TO BOTTOM OF A.C.T. SYSTEM ALTERNATES #1. ALL EXTERIOR WORK INCLUDING CANOPIES, CEDAR SIDING AND TRIM, EXTERIOR LIGHTING, REMOVAL OF PHONE BOOTHS AND PLANTERS WITH REPATCHING OF STUCCO, AND REPAINTING #2. REMOVAL OF CMU COLUMN INDICATED ON PLANS #3. RELOCATE HYDRONIC BASEBOARD HEAT TO BE AS CLOSE TO THE PERIMETER WALLS AS POSSIBLE SLATWALL EXPOSED STANDARDS EVERY 4'-0" O.C. CUT AND MOUNT SLATWALL IN BETWEEN STARDARDS, CONFIRM STANDARD LOCATIONS WITH OWNER PRIOR TO INSTALL SLATWALL SYSTEM LEGEND PAINTED 3/4" PLYWOOD PROJECT NUMBER ISSUE DATE GENERAL CONTRACTOR GE JOHNSON 40800 HIGHWAY 6, SUITE 8 P.O. BOX 8808 AVON, CO 81620 CONTACT: JOHN HALLORAN 970.471.6048 710 W. COLFAX; DENVER, C0 80204 STRUCTURAL MONROE & NEWELL 70 BENCHMARK RD. STE. 204 P.O. BOX 1587 AVON, CO 81620 CONTACT: HANNES SPAEH 970.949.7768 ELECTRICAL & LIGHTING DESIGN ARCHITECTURAL ENGINEERING CONSULTANTS 40801 US HWY 6 & 24, STE. 214 P.O. BOX 8489 AVON, CO 81620 CONTACT: STANTON HUMPHRIES 970.748.8520 REVISION SHEET TITLE SHEET NO. CHRISTY SPORTS LLC 293 BRIDGE STREET VAIL, COLORADO 81657 TOWN OF VAIL STAMP A1-01 LEVEL 1 - FLOOR PLAN 15020 CHRISTY SPORTS VAIL MARCH 18, 2016 1/4" = 1'-0" 01 LEVEL 1 No. Description Date 03/18/2016 05/27/16