Loading...
HomeMy WebLinkAboutB16-0117_A1-50_1478904920.pdfEXISTING FIXTURES TO BE UPDATED TYP. EXISTING FIXTURE TO BE UPDATED TYP. LED LIGHTING PACKAGE TO BE PROVIDED BY ELECTRICAL DESIGN- BUILD ENGINEER - COORDINATE HEIGHT OF ACT SYSTEM WITH FIXTURE REQUIREMENTS RELOCATED CHRISTY SPORTS SIGN 3' - 10" 25' - 7" 6' - 10" PROVIDE NEW GYP. BD. SOFFIT IN BAY WINDOWS FOR RETAIL DISPLAY, TYPICAL NEW GYP. BD. SOFFIT OF METAL STUDS WITH (1) LAYERS OF GYP. BD. TO MAINTAIN 1HR FIRE SEPARATION BETWEEN FLOOR ABOVE - KEEP AS TIGHT TO STRUCTURE AS POSSIBLE 19' - 6" 2' - 6" 30' - 9" MECH SHAFT 5' - 9" NEW CEDAR SOFFIT CANTILEVERED FROM EXISTING BUILDING ENSURE ALL EXIT SIGNS ARE FUNCTIONING AND CORRECTLY LOCATED FOR EGRESS 03 A7-01 6' - 0" 05 A7-01 A1-51 02 A1-51 01 PROVIDE (2) LAYERS OF GYP. BD. OVER 7/8" HAT CHANNEL AND FIRE CAULK TO MAINTAIN 1HR FIRE SEPARATION BETWEEN FLOOR ABOVE AT ALL EXPOSED CEILING PENETRATIONS PROVIDE NEW GYP. BD. SOFFIT AND LIGHTING IN FITTING ROOMS 04 A7-02 EXISTING FIXTURES TO BE UPDATED TYP. PROVIDE NEW GUTTER AND BRAKE-FORMED METAL DOWNSPOUT - PAINT TO MATCH COPPER TRIM NEW BRAKE-FORMED METAL DOWNSPOUTS - PAINT TO MATCH COPPER TRIM PROVIDE A.C.T. MOUNTED AS HIGH AS POSSIBLE TO STRUCTURE. COORDINATE WITH LIGHTING PACKAGE IF RECESSED LIGHTS ARE USED THE HEIGHT MAY NEED TO BE LOWERED DRIP EDGE INSTALLED ON EDGE OF CANOPY GUTTER AND DOWNSPOUT TO FIX DRIPS ON SKI RACK PROVIDE NEW GYPSUM BOARD BULKHEAD AS TRANSITION BETWEEN SPACES FOR ACT PROVIDE NEW GYPSUM BOARD CEILING THIS LOCATION - COORDINATE HEIGHT WITH ACT CEILING WITH OWNER PROVIDE (2) LAYERS OF GYP. BD. OVER 7/8" HAT CHANNEL AND FIRE CAULK TO MAINTAIN 1HR FIRE SEPARATION BETWEEN FLOOR ABOVE AT ALL EXPOSED CEILING PENETRATIONS PROVIDE (2) LAYERS OF GYP. BD. OVER 7/8" HAT CHANNEL AND FIRE CAULK TO MAINTAIN 1HR FIRE SEPARATION BETWEEN FLOOR ABOVE AT ALL EXPOSED CEILING PENETRATIONS PROVIDE A.C.T. MOUNTED AS HIGH AS POSSIBLE TO STRUCTURE. COORDINATE WITH LIGHTING PACKAGE IF RECESSED LIGHTS ARE USED THE HEIGHT MAY NEED TO BE LOWERED PROVIDE MINIMUM (1) 2'x2' METAL ACCESS DOOR IN THIS CEILING ASSEMBLY - PAINTED WHITE. COORDINATE LOCATION WITH OWNER 3/4" / 12" REFLECTED CEILING PLAN GENERAL NOTES 1. ALL GYPSUM BOARD CEILINGS SHALL BE 8' - 2" ABOVE FINISH FLOOR OR AS HIGH AS POSSIBLE AND PAINTED WITH INTERIOR LATEX PAINT, U.N.O. 2. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS INDICATED 3. ALL LIGHTS, DIFFUSERS, EXIT SIGNS, SMOKE DETECTORS, SPEAKERS, STROBES AND MISCELLANEOUS DEVICES SHALL BE REPLACED TO MEET CODE 4. ALL CORRIDOR SPRINKLER HEADS SHALL BE ALIGNED SUCH THAT THEY ARE PARALLEL TO AN ADJACENT WALL 5. COORDINATE EXIT SIGNS WITH ELECTRICAL AT ALL ENTRANCES AND AT TOP OF STAIR 6. ACOUSTIC CEILING TILE (ACT) BASIS OF DESIGN: ARMSTRONG FINE FISSURED 2'x4' DROP CEILING PANELS ITEM #922 WITH WHITE PRELUDE 15/16" GRID SUSPENSION SYSTEM ALTERNATES #1. ALL EXTERIOR WORK INCLUDING CANOPIES, CEDAR SIDING AND TRIM, EXTERIOR LIGHTING, REMOVAL OF PHONE BOOTHS AND PLANTERS WITH REPATCHING OF STUCCO, AND REPAINTING #2. REMOVAL OF CMU COLUMN INDICATED ON PLANS #3. RELOCATE HYDRONIC BASEBOARD HEAT TO BE AS CLOSE TO THE PERIMETER WALLS AS POSSIBLE #4. ALTERNATE CEILING TILE: USG TRUE WOOD, RED OAK, W200 WITH BLACK GRID SUSPENSION SYSTEM PROJECT NUMBER ISSUE DATE GENERAL CONTRACTOR GE JOHNSON 40800 HIGHWAY 6, SUITE 8 P.O. BOX 8808 AVON, CO 81620 CONTACT: JOHN HALLORAN 970.471.6048 710 W. COLFAX; DENVER, C0 80204 STRUCTURAL MONROE & NEWELL 70 BENCHMARK RD. STE. 204 P.O. BOX 1587 AVON, CO 81620 CONTACT: HANNES SPAEH 970.949.7768 ELECTRICAL & LIGHTING DESIGN ARCHITECTURAL ENGINEERING CONSULTANTS 40801 US HWY 6 & 24, STE. 214 P.O. BOX 8489 AVON, CO 81620 CONTACT: STANTON HUMPHRIES 970.748.8520 REVISION SHEET TITLE SHEET NO. CHRISTY SPORTS LLC 293 BRIDGE STREET VAIL, COLORADO 81657 TOWN OF VAIL STAMP A1-50 LEVEL 1 REFLECTED CEILING PLAN 15020 CHRISTY SPORTS VAIL MARCH 18, 2016 1/4" = 1'-0" 01 LEVEL 1 RCP No. Description Date 03/18/2016 05/27/16