HomeMy WebLinkAboutB16-0117_A1-50_1478904920.pdfEXISTING FIXTURES TO
BE UPDATED TYP.
EXISTING FIXTURE TO
BE UPDATED TYP.
LED LIGHTING PACKAGE
TO BE PROVIDED BY
ELECTRICAL DESIGN-
BUILD ENGINEER -
COORDINATE HEIGHT OF
ACT SYSTEM WITH FIXTURE
REQUIREMENTS
RELOCATED CHRISTY
SPORTS SIGN 3' - 10"
25' - 7"
6' - 10"
PROVIDE NEW GYP.
BD. SOFFIT IN BAY
WINDOWS FOR
RETAIL DISPLAY,
TYPICAL
NEW GYP. BD. SOFFIT OF
METAL STUDS WITH (1)
LAYERS OF GYP. BD. TO
MAINTAIN 1HR FIRE
SEPARATION BETWEEN
FLOOR ABOVE - KEEP AS
TIGHT TO STRUCTURE AS
POSSIBLE
19' - 6"
2' - 6"
30' - 9"
MECH
SHAFT 5' - 9"
NEW CEDAR SOFFIT
CANTILEVERED FROM
EXISTING BUILDING
ENSURE ALL EXIT SIGNS ARE
FUNCTIONING AND
CORRECTLY LOCATED FOR
EGRESS
03
A7-01
6' - 0"
05
A7-01
A1-51
02
A1-51
01
PROVIDE (2) LAYERS OF
GYP. BD. OVER 7/8" HAT
CHANNEL AND FIRE
CAULK TO MAINTAIN 1HR
FIRE SEPARATION
BETWEEN FLOOR ABOVE
AT ALL EXPOSED
CEILING PENETRATIONS
PROVIDE NEW GYP.
BD. SOFFIT AND
LIGHTING IN FITTING
ROOMS
04
A7-02
EXISTING FIXTURES TO
BE UPDATED TYP.
PROVIDE NEW GUTTER AND
BRAKE-FORMED METAL
DOWNSPOUT - PAINT TO
MATCH COPPER TRIM
NEW BRAKE-FORMED
METAL DOWNSPOUTS
- PAINT TO MATCH
COPPER TRIM
PROVIDE A.C.T. MOUNTED AS
HIGH AS POSSIBLE TO
STRUCTURE. COORDINATE
WITH LIGHTING PACKAGE IF
RECESSED LIGHTS ARE USED
THE HEIGHT MAY NEED TO BE
LOWERED
DRIP EDGE INSTALLED
ON EDGE OF CANOPY
GUTTER AND
DOWNSPOUT TO FIX
DRIPS ON SKI RACK
PROVIDE NEW GYPSUM
BOARD BULKHEAD AS
TRANSITION BETWEEN
SPACES FOR ACT
PROVIDE NEW GYPSUM
BOARD CEILING THIS
LOCATION - COORDINATE
HEIGHT WITH ACT CEILING
WITH OWNER
PROVIDE (2) LAYERS OF
GYP. BD. OVER 7/8" HAT
CHANNEL AND FIRE
CAULK TO MAINTAIN 1HR
FIRE SEPARATION
BETWEEN FLOOR ABOVE
AT ALL EXPOSED
CEILING PENETRATIONS
PROVIDE (2) LAYERS OF
GYP. BD. OVER 7/8" HAT
CHANNEL AND FIRE
CAULK TO MAINTAIN 1HR
FIRE SEPARATION
BETWEEN FLOOR ABOVE
AT ALL EXPOSED
CEILING PENETRATIONS
PROVIDE A.C.T. MOUNTED
AS HIGH AS POSSIBLE TO
STRUCTURE. COORDINATE
WITH LIGHTING PACKAGE IF
RECESSED LIGHTS ARE
USED THE HEIGHT MAY
NEED TO BE LOWERED
PROVIDE MINIMUM (1)
2'x2' METAL ACCESS
DOOR IN THIS CEILING
ASSEMBLY - PAINTED
WHITE. COORDINATE
LOCATION WITH OWNER
3/4" / 12"
REFLECTED CEILING PLAN GENERAL NOTES
1. ALL GYPSUM BOARD CEILINGS SHALL BE 8' - 2" ABOVE FINISH
FLOOR OR AS HIGH AS POSSIBLE AND PAINTED WITH INTERIOR
LATEX PAINT, U.N.O.
2. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR
MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS
INDICATED
3. ALL LIGHTS, DIFFUSERS, EXIT SIGNS, SMOKE DETECTORS,
SPEAKERS, STROBES AND MISCELLANEOUS DEVICES SHALL BE
REPLACED TO MEET CODE
4. ALL CORRIDOR SPRINKLER HEADS SHALL BE ALIGNED SUCH
THAT THEY ARE PARALLEL TO AN ADJACENT WALL
5. COORDINATE EXIT SIGNS WITH ELECTRICAL AT ALL ENTRANCES
AND AT TOP OF STAIR
6. ACOUSTIC CEILING TILE (ACT) BASIS OF DESIGN: ARMSTRONG
FINE FISSURED 2'x4' DROP CEILING PANELS ITEM #922 WITH
WHITE PRELUDE 15/16" GRID SUSPENSION SYSTEM
ALTERNATES
#1. ALL EXTERIOR WORK INCLUDING CANOPIES, CEDAR SIDING AND
TRIM, EXTERIOR LIGHTING, REMOVAL OF PHONE BOOTHS AND
PLANTERS WITH REPATCHING OF STUCCO, AND REPAINTING
#2. REMOVAL OF CMU COLUMN INDICATED ON PLANS
#3. RELOCATE HYDRONIC BASEBOARD HEAT TO BE AS CLOSE TO
THE PERIMETER WALLS AS POSSIBLE
#4. ALTERNATE CEILING TILE: USG TRUE WOOD, RED OAK, W200
WITH BLACK GRID SUSPENSION SYSTEM
PROJECT NUMBER
ISSUE DATE
GENERAL CONTRACTOR
GE JOHNSON
40800 HIGHWAY 6, SUITE 8
P.O. BOX 8808
AVON, CO 81620
CONTACT: JOHN HALLORAN 970.471.6048
710 W. COLFAX; DENVER, C0 80204
STRUCTURAL
MONROE & NEWELL
70 BENCHMARK RD. STE. 204
P.O. BOX 1587
AVON, CO 81620
CONTACT: HANNES SPAEH 970.949.7768
ELECTRICAL & LIGHTING DESIGN
ARCHITECTURAL ENGINEERING CONSULTANTS
40801 US HWY 6 & 24, STE. 214
P.O. BOX 8489
AVON, CO 81620
CONTACT: STANTON HUMPHRIES 970.748.8520
REVISION
SHEET TITLE
SHEET NO.
CHRISTY
SPORTS LLC
293 BRIDGE
STREET
VAIL,
COLORADO
81657
TOWN
OF VAIL
STAMP
A1-50
LEVEL 1 REFLECTED
CEILING PLAN
15020
CHRISTY
SPORTS
VAIL
MARCH 18, 2016
1/4" = 1'-0"
01 LEVEL 1 RCP
No. Description Date
03/18/2016
05/27/16