Loading...
HomeMy WebLinkAboutB16-0117_E2.0_1478904946.pdfPROJECT: CHRISTIE SPORTS PANEL ENGINEER: SOH PROJECT #: 15022 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 80A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION COMPUTER POWER 500 20 1 1 2 2 20 1000 BOOT HEAT DOWNSTAIRS LIGHTING 1344 20 1 3 4 1000 " DOWNSTAIRS LIGHTING 1344 20 1 5 6 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 7 8 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 9 10 1 20 500 UNIDENTIFIED WEST OFFICE LIGHTING & REC 500 20 1 11 12 1 20 200 BASEMENT OFFICE LTG BATHRM & STORAGE 500 20 1 13 14 1 20 500 DISPOSAL AIR HANDLER KITCHEN LIGHTING & REC 500 20 1 15 16 1 20 500 UNIDENTIFIED COMPUTER REC 500 20 1 17 18 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 19 20 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 21 22 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 23 24 1 20 500 UNIDENTIFIED UNIDENTIFIED 500 20 1 25 26 1 20 500 UNIDENTIFIED SNOWBOARD GRINDER 1500 20 1 27 28 1 20 500 BOOT RM WAX MACHINE 1500 20 1 29 30 1 20 500 UNIDENTIFIED 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY CONTRACTOR TO TRACE EXISTING CIRCUITS AND IDENTIFY AND ESTABLISH LOADS FOR "UNIDENTIFIED" CIRCUITS. CALCULATED POWER FACTOR: 1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 2688 13 3360 16 RECEPTACLES 16700 80 13350 64 MECHANICAL 0 0 0 0 KITCHEN 0 0 0 0 TOTAL 19388 93 16710 80 CHRISTIE SPORTS SUB PANEL AT RIGHT PROJECT: CHRISTIE SPORTS PANEL ENGINEER: SOH PROJECT #: 15022 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 200A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION SPACE 0 1 2 0 SPACE SPACE 0 3 4 0 SPACE GRINDRITE 2050 30 2 5 6 2 80 9694 SUB PANEL TO THE RIGHT " 2050 7 8 9694 " WINTERSTEIGER 468 20 2 9 10 0 SPACE " 468 11 12 0 SPACE STORE RECEPTACLES 360 20 1 13 14 1 20 1533 MAIN LEVEL LIGHTING STORE RECEPTACLES 360 20 1 15 16 1 20 792 MAIN LEVEL LIGHTING STORE RECEPTACLES 180 20 1 17 18 1 20 792 MAIN LEVEL LIGHTING SPACE 0 19 20 0 SPACE SPACE 0 21 22 0 SPACE SPACE 0 23 24 0 SPACE SPACE 0 25 26 0 SPACE SPACE 0 27 28 0 SPACE SHOW WINDOW RECEPTACLE1080 20 1 29 30 0 SPACE SHOW WINDOW RECEPTACLE 1080 20 1 31 32 0 SPACE SHOW WINDOW RECEPTACLE1080 20 1 33 34 0 SPACE W DOOR 1000 20 1 35 36 0 SPACE FRONT AUTOMATIC DOOR 1000 20 1 37 38 0 SPACE EXISTING DOOR CURTAIN 108 20 1 39 40 0 SPACE EXISTING DOOR CURTAIN 108 20 1 41 42 0 SPACE LOAD CALCULATION SUMMARY NEW CIRCUITS ARE CLOUDED, REST ARE EXISTING CALCULATED POWER FACTOR: 1.00 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 5805 28 7256 35 RECEPTACLES 27876 134 18938 91 MECHANICAL 216 1 243 1 KITCHEN 0 0 0 0 TOTAL 33897 163 26437 127 CHRISTIE SPORTS PANEL A Back-Lit LED Mirror Back-Lit LED Mirror Locate Electrical Panel behind fitting room mirror Back-Lit LED Mirror 05/27/16