Loading...
HomeMy WebLinkAboutB16-0117_LS-02_1478904934.pdfUP DN HALLWAY REST. REST. SKI RENTAL WAITING RENATL SKIS BREAK ROOM OFFICE RENTAL SKIS MECH. RM. MECH. 50' - 8" 44' - 11" EGRESS ELECTRICAL PANEL ELECTRICAL PANEL MECHANICAL CHASE E E E 71' - 5" 61' - 5" PROJECT NUMBER ISSUE DATE GENERAL CONTRACTOR GE JOHNSON 40800 HIGHWAY 6, SUITE 8 P.O. BOX 8808 AVON, CO 81620 CONTACT: JOHN HALLORAN 970.471.6048 710 W. COLFAX; DENVER, C0 80204 STRUCTURAL MONROE & NEWELL 70 BENCHMARK RD. STE. 204 P.O. BOX 1587 AVON, CO 81620 CONTACT: HANNES SPAEH 970.949.7768 ELECTRICAL & LIGHTING DESIGN ARCHITECTURAL ENGINEERING CONSULTANTS 40801 US HWY 6 & 24, STE. 214 P.O. BOX 8489 AVON, CO 81620 CONTACT: STANTON HUMPHRIES 970.748.8520 REVISION SHEET TITLE SHEET NO. CHRISTY SPORTS LLC 293 BRIDGE STREET VAIL, COLORADO 81657 TOWN OF VAIL STAMP LS-01 LIFE SAFETY PLANS 15020 CHRISTY SPORTS VAIL MARCH 18, 2016 PROJECT INFORMATION Project Name: Vail Christy Sports Tenant Improvement Location: 293 Bridge Street, Vail, Colorado 81657 Block 5-C, Vail Village First Filing Tenant: Christy Sports, LLC Building Owner: Plaza Lodge Associates, LLC Authority Having Jurisdiction: City of Vail, Colorado 2015 International Building Code 2015 International Residential Code 2015 International Fire Code 2015 International Plumbing Code 2015 International Mechanical Code 2015 International Fuel Gas Code 2015 International Energy Conservation Code and TOV Amendments 2015 International Performance Code for Building and Facilities 2014 National Electrical Code Ground Snow Load is 145 pounds per square foot Wind Speed is 90 miles per hour (3 second gust) and Exposure B II. USE AND OCCUPANCY CLASSIFICATION Occupancy Classification: B – Business III. ALLOWABLE AREA AND HEIGHT Existing Tenant Basement 2,700 SF Existing Tenant First Floor 3,380 SF Total Existing Tenant Space 6,080 SF OCCUPANT LOAD: 61 Existing Building Number of Stories: 3 with Basement Existing Building Construction Type: V-B Existing Tenant Space: Ground Floor with Basement Description of existing Type V-B Construction space: It has been confirmed that the entire building is equipped with fire sprinklers. These are notably black iron in the basement level where they are exposed but they are plastic (orange) in most locations on the first floor and above. The plastic will need to be replaced with iron in all areas where the ceilings are to be completely open and exposed. IV. TYPE OF CONSTRUCTION 1. Building Elements: a. Structural Frame: 0 HR b. Bearing Walls – Exterior 0 HR c. Bearing Walls – Interior 0 HR d. Non-bearing Walls – Exterior: 0 HR e. Non-bearing Walls – Interior: 0 HR f. Floor Construction: 0 HR 2. Exterior Wall Rating based on Fire Separation Distance a. <5’ 1 HR b. 5’ – 10’ 1 HR c. 10’ – 30’ 0 HR d. >30’ 0 HR 3. Allowable Area of Openings (based on fire separation distance and having a fire sprinkler system): a. 3’-5’ 15% b. 5’-10’ 25% c. 10’-15’ 45% d. 15’-20’ 75% e. 20’-25’ Unlimited No change to existing opening sizes, glazing is to be replaced. V. FIRE PROTECTION SYSTEMS Smoke and heat detection is adequate. Fire panel will need to be upgraded AS existing panel is no longer serviceable. Removal of existing suspended ceiling system will require relocation of existing fire sprinklers for coverage and direction of spray. VI. EXIT REQUIREMENTS Does not apply: no change will be made to the existing exits during this remodel. VII. ACCESSIBILITY The proposed alternations are not adding additional space or obstacles to the building. Note: The First Floor is the only area of the tenant space that will be remodeled along with refinishing the stair treads to the lower level Ski Rental shop. 3/32" = 1'-0" 01 BASEMENT LIFE SAFETY 3/32" = 1'-0" 02 LEVEL 1 LIFE SAFETY No. Description Date 03/18/2016 05/27/16