Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MXZ-3B30NA.pdf
Job Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. GENERAL FEATURES• Compact side discharge outdoor unit• Wireless or wired remote controller, depending on the indoor units used• Quiet operation—both indoor and outdoor units• Automatic fan speed control• Auto restart following power outage• Self-check function—integrated diagnostics• Advanced microprocessor control• Limited warranty: five years on parts and defects and seven years on compressors OPTIONAL OUTDOOR UNIT ACCESSORIES □Air Outlet Guide (MAC-856SG) □3/8" x 1/2" Port Adapter (MAC-A454JP-E) □1/2" x 3/8" Port Adapter (MAC-A455JP-E) □1/2" x 5/8" Port Adapter (MAC-A456JP-E) □1/4" x 3/8" Port Adapter (PAC-493PI) □3/8" x 5/8" Port Adapter (PAC-SG76RJ-E) Cooling*Rated Capacity (Non-ducted/Ducted)...28,400 Btu/h / 27,400 Btu/hMinimum Capacity (Non-ducted/Ducted) ..12,600 Btu/h / 12,600 Btu/hTotal Input (Non-ducted/Ducted)..............3,120 W / 3,330 W Heating at 47°F*Rated Capacity (Non-ducted/Ducted)...28,600 Btu/h / 27,600 Btu/hMinimum Capacity (Non-ducted/Ducted)..11,400 Btu/h / 11,400 Btu/hTotal Input (Non-ducted/Ducted)..............2,150 W / 2,220 W Heating at 17°F*Rated Capacity (Non-ducted/Ducted) ...16,000 Btu/h / 15,100 Btu/hTotal Input (Non-ducted/Ducted).............2,120 W / 2,190 W* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB. Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.(Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB / 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 17ºF (-8ºC) DB / 15ºF (-9ºC) WB. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzRecommended Fuse/Breaker Size.......................20 AMCA ............................................. 15 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 ........................DC 12 - 24V OPERATING RANGE Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 14ºF (-10ºC) DB Heating Maximum 80ºF (27ºC) DB, 67ºF (19ºC) WB 75ºF (24ºC) DB, 65ºF (18ºC) WB Minimum 70ºF (21ºC) DB, 60ºF (16ºC) WB 6ºF (-14ºC) DB, 5ºF (-15ºC) WB Compressor ..................DC Inverter-driven Twin RotaryFan Motor....................................0.93 F.L.A. Sound Pressure LevelCooling (Non-ducted/Ducted)..................... . . 49 dB(A)Heating (Non-ducted/Ducted)...................... . 49 dB(A) DIMENSIONS INCHES / MM W 35-7/16 / 900 D 12-5/8 / 321 H 35-7/16 / 900 Weight ...................................150 lbs. / 68 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1Refrigerant Type..................................R410ARefrigerant Pipe Size O.D. ― Three Ports Gas Side...............A: 1/2" / 12.7mm; B,C: 3/8" / 9.52 mm Liquid Side ................................1/4" / 6.35 mmMax. Refrigerant Pipe Length.....................230' / 70 mMax. Piping Length for Each Indoor Unit .............82' / 25 mMax. Refrigerant Pipe Height Difference If Indoor Unit is Above Outdoor Unit................49' / 15 m If Indoor Unit is Below Outdoor Unit................33' / 10 mConnection Method ................................Flared SUBMITTAL DATA: MXZ-3B30NA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the Technical and Service Manuals.) Outdoor Unit: MXZ-3B30NA MXZ-3B30NA ENERGY EFFICIENCIESCOMPATIBLE INDOOR UNITS Refer to the separate submittal forms for the SEZ, PEAD, MSZ, MFZ, PCA, SLZ, and PLA Indoor Units. Wall-mounted Indoor Units: MSZ-FE09,12,18NA Wall-mounted Indoor Units: MSZ-GE06,09,12,15,18, 24NA Horizontal-ducted Indoor Units: SEZ-KD09,12,15,18NA and PEAD-A24AA Floor-standing Indoor Units: MFZ-KA09,12,18NA Ceiling-suspended Indoor Units: PCA-A24KA Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Non-ducted (06 + 06 + 09)17.5 9.1 10.5 3.9 2.77 Ducted and Non-ducted 16 8.7 10.0 3.8 2.775 Ducted (09 + 09 + 09)14.5 8.2 9.5 3.64 2.78 Ceiling-cassette Indoor Units: SLZ-KA09,12,15NA and PLA-A18,24BA © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. MXZ-3B30NA OPERATION PERFORMANCE • Minimum of two Indoor Units must be connected to the MXZ-3B30NA. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on (see table below for single Indoor Unit performance). • Indoor Units can be All Non-ducted, All Ducted, or a Combination of Non-ducted and Ducted (Select style as installa- tion requires). • Information provided at 208/230V. Refer to the MXZ Outdoor Unit Service Manual for detailed specifications and additional information per Indoor Unit Combination. Operation Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Power Usage Range (W)Heating Capacity Range (Btu/h) Unit A Unit B Unit C Total Range 6 6,500 --5,200 - 6,500 460 - 580 7,800 --6,800 - 14,400 540 - 1,460 9 9,000 --7,200 - 9,000 580 - 820 10,900 --8,600 - 15,400 780 - 1,520 12 12,000 --7,200 - 12,000 580 - 1,020 13,600 - 14,400 --8,600 - 16,400 780 - 1,600 15 14,000 - 15,000 --7,200 - 15,000 580 - 1,340 18,000 --8,600 - 21,100 780 - 2,280 18 17,200 --7,200 - 17,200 580 - 1,590 21,600 --8,600 - 24,900 780 - 2,770 24 22,000 7,200 - 22,000 580 - 2,200 23,200 --8,600 - 27,800 780 - 3,000 6 + 6 6,500 6,500 -12,000 - 13,000 920 - 960 7,800 7,800 -11,000 - 31,000 740 - 2,560 6 + 9 6,500 9,000 -12,000 - 15,500 920 - 1,260 7,800 10,900 -11,000 - 31,000 740 - 2,560 6 + 12 6,500 12,000 -12,000 - 18,500 920 - 1,600 7,800 13,600 -11,000 - 31,000 740 - 2,560 6 + 15 6,500 14,000 - 15,000 -12,000 - 21,500 920 - 1,940 7,800 18,000 -11,000 - 33,000 740 - 2,800 6 + 18 6,500 17,200 -12,000 - 23,700 920 - 2,460 7,200 19,800 -11,000 - 35,000 740 - 2,920 6 + 24 5,900 20,100 12,000 - 26,000 920 - 2,800 6,800 20,200 -11,000 - 35,000 740 - 2,860 9 + 9 9,000 9,000 -12,000 - 18,000 920 - 1,840 10,900 10,900 -11,000 - 31,000 740 - 2,560 9 + 12 9,000 12,000 -12,000 - 21,000 920 - 2,040 10,900 13,600 - 14,400 -11,000 - 33,000 740 - 2,800 9 + 15 9,000 15,000 -12,000 - 24,000 920 - 2,540 10,100 16,900 -11,000 - 35,000 740 - 2,920 9 + 18 8,900 17,100 -12,000 - 26,000 920 - 2,840 9,000 18,000 -11,000 - 35,000 740 - 2,920 9 + 24 7,600 20,400 -12,000 - 28,000 920 - 3,220 7,300 19,700 -11,000 - 35,000 740 - 2,740 12 + 12 12,000 12,000 -12,000 - 24,000 920 - 2,540 13,500 13,100 - 13,500 -11,000 - 35,000 740 - 2,920 12 + 15 11,500 14,500 -12,000 - 26,000 920 - 2,840 11,600 - 12,000 15,000 - 15,400 -11,000 - 35,000 740 - 2,860 12 + 18 10,400 15,600 -12,000 - 26,000 920 - 2,840 10,400 - 10,800 16,200 - 16,600 -11,000 - 35,000 740 - 2,860 15 + 15 13,000 13,000 -12,000 - 26,000 920 - 2,840 13,500 13,500 -11,000 - 35,000 740 - 2,800 15 + 18 11,700 - 11,800 14,200 - 14,300 -12,000 - 26,000 920 - 2,840 12,300 14,700 -11,000 - 35,000 740 - 2,800 18 + 18 13,000 13,000 -12,000 - 26,000 920 - 2,840 13,500 13,500 -11,000 - 35,000 740 - 2,800 © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Operation Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C) Cooling Capacity Range (Btu/h) Power Usage Range (W)Heating Capacity Range (Btu/h) Unit A Unit B Unit C Total Range 6 + 6 + 6 6,500 6,500 6,500 12,600 - 19,500 1,000 - 1,600 7,800 7,800 7,800 11,400 - 36,000 740 - 2,820 6 + 6 + 9 6,500 6,500 9,000 12,600 - 22,000 1,000 - 1,940 7,800 7,800 10,900 11,400 - 36,000 740 - 2,820 6 + 6 + 12 6,500 6,500 12,000 12,600 - 25,000 1,000 - 2,330 7,450 - 7,650 7,450 - 7,650 13,300 - 13,700 11,400 - 36,000 740 - 2,820 6 + 6 + 15 6,500 6,500 14,000 - 15,000 12,600 - 28,000 1,000 - 2,580 6,650 6,650 15,300 11,400 - 36,000 740 - 2,820 6 + 6 + 18 6,100 6,100 16,200 12,600 - 28,400 1,000 - 3,190 6,000 6,000 16,600 11,400 - 36,000 740 - 2,820 6 + 9 + 9 6,500 9,000 9,000 12,600 - 24,500 1,000 - 2,290 7,600 10,000 - 10,500 10,000 - 10,500 11,400 - 36,000 740 - 2,820 6 + 9 + 12 6,500 9,000 12,000 12,600 - 27,500 1,000 - 2,690 6,800 - 6,900 8,900 - 9,700 12,000 - 12,400 11,400 - 36,000 740 - 2,820 6 + 9 + 15 6,000 - 6,200 7,900 - 8,700 13,500 - 14,000 12,600 - 28,400 1,000 - 3,260 6,100 8,000 - 8,500 14,000 11,400 - 36,000 740 - 2,820 6 + 9 + 18 5,600 7,300 - 7,600 15,000 12,600 - 28,400 1,000 - 3,260 5,600 7,200 - 7,700 15,300 11,400 - 36,000 740 - 2,820 6 + 12 + 12 6,000 11,200 11,200 12,600 - 28,400 1,000 - 3,260 6,100 - 6,400 11,100 - 11,500 10,900 - 11,250 11,400 - 36,000 740 - 2,820 6 + 12 + 15 5,500 - 5,700 10,200 - 10,500 12,600 - 12,700 12,200 - 28,400 1,000 - 3,260 5,550 - 5,600 9,900 - 10,250 12,800 - 13,100 11,400 - 36,000 740 - 2,820 6 + 15 + 15 5,000 - 5,400 11,200 - 11,700 11,500 - 12,000 12,600 - 28,400 1,000 - 3,260 5,100 11,750 11,750 11,400 - 36,000 740 - 2,820 9 + 9 + 9 8,500 - 9,000 8,500 - 9,000 8,500 - 9,000 12,600 - 27,000 1,000 - 2,950 9,000 - 9,500 9,000 - 9,500 9,000 - 9,500 11,400 - 36,000 740 - 2,820 9 + 9 + 12 8,000 - 8,500 8,000 - 8,500 11,400 12,600 - 28,400 1,000 - 3,330 8,100 - 8,800 8,100 - 8,800 11,000 - 11,400 11,400 - 36,000 740 - 2,820 9 + 9 + 15 7,250 - 8,000 7,250 - 8,000 12,400 - 12,900 12,600 - 28,400 1,000 - 3,330 7,300 - 7,800 7,300 - 7,800 13,000 11,400 - 36,000 740 - 2,820 9 + 9 + 18 6,600 - 7,100 6,600 - 7,100 14,200 12,600 - 28,400 1,000 - 3,330 6,700 - 7,200 6,700 - 7,200 14,200 11,400 - 36,000 740 - 2,820 9 + 12 + 12 7,300 - 7,800 10,300 10,300 12,600 - 28,400 1,000 - 3,330 7,300 - 8,200 10,200 - 10,600 10,000 - 10,400 11,400 - 36,000 740 - 2,820 9 + 12 + 15 6,600 - 7,300 9,500 - 9,700 11,400 - 11,800 12,600 - 28,400 1,000 - 3,330 6,700 - 7,300 9,200 - 9,500 11,900 - 12,100 11,400 - 36,000 740 - 2,820 MXZ-3B30NA OPERATION PERFORMANCE, contd. 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice. © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC.FORM# MXZ-3B30NA for Multiple Indoor Unit Styles - 201109 DIMENSIONS: MXZ-3B30NA