Loading...
HomeMy WebLinkAboutPUMY-P60NKMU(-BS).pdfJob Name: Schedule Reference:Date: Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. Model: PUMY-P60NKMU (-BS) Specifications Model Name Unit Type PUMY-P60NKMU (-BS) Nominal Cooling Capacity(208/230V)Btu/h 60,000 Nominal Heating Capacity (208/230V)Btu/h 66,000 Operating Temperature Range Cooling (Outdoor) *1 23° F ~ 115° F (-5 ° ~ +46° C) DB Heating (Outdoor)-4° F ~ +60° F (-20 ° ~ +15° C) WB External Dimensions (H x W x D)In. / mm 52-11/16 x 41-5/16 x 13 (+1-3/16) / 1,338 x 1050 x 330 (+30) External finish Precoated Galvanized-steel Sheets Net Weight Lbs. / kg 313 / 142 Electrical Power Requirements Voltage, Phase, Hertz 208 / 230V, 1-phase, 60Hz Minimum Circuit Ampacity (MCA)A 35 Recommended Fuse/Breaker Size A 40 Maximum Fuse Size A 42 Piping Diameter (Flared) (In. / mm)Liquid (High Pressure)3/8 / 9.52 Gas (Low Pressure)3/4 / 19.05 Indoor Unit Total Capacity 50 to 130% of Outdoor Unit Capacity Model / Quantity P06 to P72 / 1 to 12 Sound Pressure Levels dB(A)58/59 Fan Type x Quantity Propeller Fan x 2 Airflow Rate CFM 4,940 Compressor Operating Range Cooling 38% to 100% Heating 29% to 100% Compressor Type x Quantity INVERTER-driven Scroll Hermetic x 1 Compressor Motor Output kW 3.0 Refrigerant R410A Lubricant FV50S High-pressure Protection Device High Pressure Switch Compressor / Fan Protection Device Compressor Thermo / Overcurrent Detection Inverter Protection Device Overheat / Voltage Protection AHRI RatingsDucted (06 + 06 + 06 + 18 + 24) / Non-Ducted (24 + 24 + 06 + 06) EER 11.3 / 12.5 SEER 16.5 / 16.7 COP 3.70 / 3.14 Blue Fin Anti-corrosion Protection: Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants; ≥1μm thick; Salt Spray Test Method - no unusual rust development to 960 hours. SEACOAST PROTECTION • External Panel Base, External Front Panel, Pillar: Alloyed galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces• Compressor Cover: Galvanized-aluminum sheets with thermoset polyester-resin coating on internal and external surfaces• Electrical Parts Box: Galvanized-aluminum sheets with thermoset polyester-resin coating on external surface• Fan Motor Support: Galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces• Printed Circuit Board: Epoxy resin with polyurethane-coating on external surface OUTDOOR VRF SYSTEM FEATURES • Single-phase outdoor unit with variable refrigerant flow (VRF) zoning technology • Inverter-driven (variable speed) compressor • Total refrigerant piping length of 492' (150 m) • Connects up to 12 indoor units • Uses CITY MULTI indoor units and Controls Network UNIT OPTION □Standard Model……………………….....PUMY-P60NKMU □Sea Coast (BS) Model…………......PUMY-P60NKMU-BS OPTIONAL PARTS □Joint Kit...........…for details see Pipe Accesories Submittal □Header Kit......…for details see Pipe Accesories Submittal □Air Outlet Guide (One Piece)**……......….......PAC-SH96SG-E □Wind Baffle (One Piece)**…....………………………WB-PA3 □Drain Pan…………………………………....PAC-SH97DP-E □Drain Socket………………………….…......PAC-SH71DS-E NOTES: *1. If PKFY-P06/08 indoor units are connected, then range is 50° F ~ 115° F (10° C ~ 46° C). **PUMY requires two outlet guides and wind baffles for installation. Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. 1340 Satellite BoulevardSuwanee, GA 30024Toll Free: 800-433-4822www.mehvac.com Model: PUMY-P60NKMU (-BS) – DIMENSIONS FORM# PUMY-P60NKMU (-BS) - 201504 1717 5 OUTLINES AND DIMENSIONS PUMY-P60NKMU PUMY-P60NKMU-BS Unit : mm <inch>ޓޓ࡮࡮࡮Refrigerant GAS pipe connection (FLARE):19.05㧔3/4F)ޓޓ࡮࡮࡮Refrigerant LIQUID pipe connection (FLARE): 9.52㧔3/8F㧕+㧝࡮࡮࡮Indication of STOP VALVE connection location.12Min.Min.Min.Min.Service space<Foundation bolt height>Max.The diagram below shows a basic example.Explantion of particular details aregiven in the installation manuals etc.Dimensions of space neededfor service access areshown in the below diagram.Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts and washers must be purchased locally.)1 FREE SPACE (Around the unit)2 SERVICE SPACE3 FOUNDATION BOLTS4 PIPING-WIRING DIRECTIONSPiping and wiring connectionscan be made from 4 directions:FRONT, Right, Rear and Below.30<1-3/16>150<5-29/32>500<19-11/16>500<19-11/16>10<3/8>Example of NotesPiping Knockout Hole DetailsFOUNDATIONDrain hole㧔5-:33<1-5/16>)Bottom piping hole(Knockout)154<6-1/16>136<5-11/32>45<1-25/32>110<4-11/32>160<6-5/16>160<6-5/16>160<6-5/16>81<3-3/16>86<3-3/8>Ground for the power supply("GR"marking position)Service panelHandle for moving21Terminal connectionLeft࡮࡮࡮For the power supplyCenter࡮࡮࡮For the transmission lineRight࡮࡮For concentration control( )Ground for the transmission lineGround for concentration controlHandle for moving+1ޓ450<17-23/32>+1ޓ393<15-15/32>1079<42-15/32>1050<41-11/32>26<1-1/32>369<14-17/32>632<24-7/8>1338<52-11/16>362<14-1/4>Scale 1:53/4 ConduitattachmentWhen installing the conduit.Set the attachment to the inner side of each panel.:27.8<1-3/32>:22.2<7/8>1/2 Conduitattachment100<3-15/16>24.7<31/32>5<3/16>22.5<7/8>60<2-3/8>Min. 1000mm<39-3/8>Min. 150mm<5-29/32>Min. 10mm<3/8>Min. 10mm<3/8>FREERear piping hole(Knockout)Rear trunking hole(Knockout)Conduit hole(:37<1-15/32>Knockout)Conduit hole(:24<15/16>Knockout)60<2-3/8>55<2-3/16>55<2-3/16>27<1-1/16>26<1-1/32>5<3/16>60<2-3/8>73<2-7/8>92<3-5/8>75<2-15/16>:92<3-5/8>Right trunking hole(Knockout)Conduit hole(:37<1-15/32>Knockout)Conduit hole(:24<15/16>Knockout)Right piping hole(Knockout)73<2-7/8>60<2-3/8>5<3/16>29<1-5/32>27<1-1/16>26<1-1/32>92<3-5/8>53<2-3/32>60<2-3/8>55<2-3/16>92<3-5/8>:92<3-5/8>Conduit hole(:24<15/16>Knockout)Front piping hole(Knockout)Front trunking hole(Knockout)Conduit hole(:37<1-15/32>Knockout)60<2-3/8>55<2-3/16>26<1-1/32>5<3/16>60<2-3/8>73<2-7/8>75<2-15/16>92<3-5/8>27<1-1/16>55<2-3/16>:92<3-5/8>Air DischargeRear Air IntakeSide Air Intake2-12×36 Oval holes(Foundation Bolt M10<W3/8>)2-U Shaped notched holes(Foundation Bolt M10<W3/8>)Installation Feet25<31/32>417<16-13/32>42<1-21/32>61<2-13/32>70<2-3/4>28<1-3/32>19<3/4>370<14-9/16>225<8-27/32>600<23-5/8>225<8-27/32>330<13>53<2-3/32>56<2-7/32>40<1-9/16>0Rear piping coverFront piping coverAir intakeSide Air IntakeRear Air IntakeHandle formovingHandle formovingOCH502