Loading...
HomeMy WebLinkAboutSLZ-KA09NA_For_MXZ.pdfM-SERIES Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SPECIFICATIONS Cooling Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8,400 Btu/hHeating Capacity at 47°F* . . . . . . . . . . . . . . . . . . . . .10,900 Btu/h Electrical RequirementsPower Supply . . . . . . . . . . . . . . . . . . . .208 / 230V, 1-Phase, 60 HzMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 A VoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . .AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . .DC ±24VFan Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 .23 F .L .A . Airflow (Lo - Med - Hi) . . . . . . . . . . . . . . . . .280 - 320 - 350 Dry CFM250 - 290 - 320 Wet CFM Air Filter . . . . . . . . . . . . . . . . . . . . . . . . .Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi) . . . . . . . . .29 - 32 - 38 dB(A) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 570 25-5/8 / 650 D 22-7/16 / 570 25-5/8 / 650 H 9-1/4 / 235 13/16 / 20 Weight (Unit/Grille) Lbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 / 7 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 .5 / 3External Finish (Unit/Grille) . . . . . . . . . .Galvanized-steel Sheets / Munsell 6 .4Y 8 .9 / 0 .4Field Drainpipe Size O .D . . . . . . . . . . . . . . . . . . . . . .1-1/4” / 32 mm Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R410ARefrigerant Pipe Size O .D . Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9 .52 mm Liquid Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4" / 6 .35 mmConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flared SUBMITTAL DATA: SLZ-KA09NA 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS ACCESSORIESIndoor Unit □Grille (SLP-15AAUW; required - shipped with unit) GENERAL FEATURES• Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications• Built-in drain mechanism for condensate removal; lifts to 19-11/16"• Wide air-flow pattern for better air distribution• Design features ventilation air intake knockout• Long-life air filter included with indoor unit• Indoor unit powered from outdoor unit using A-Control• Choice of fan speed: Low, Medium, High• Automatic restart following a power outage• Limited warranty: five years parts and seven years compressors Controller Options □Wireless Wall-mounted Remote Controller Kit (MHK1)* □Portable Central Controller (MCCH1)* □Outdoor Air Sensor (MOS1)* □Wired Wall-mounted Controller (PAR-31MAA)* □Simple MA Remote Controller (PAC-YT53CRAU)**See Submittal for information on each option . □Remote Temperature Sensor (M21-JKO-307) □Hand-held Wireless Remote Controller (PAR-FL32MA;req .PAR-FA32MA-E) □Wireless Signal Receiver PAR-FA32MA (for PAR-FL32MA) □Lockdown Bracket for Hand-held Controller (RCMKP1CB) SLZ-KA09NA * Rating Conditions per AHRI Standard Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WBHeating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ Technical and Service Manual.) 1340 Satellite Boulevard Suwanee, GA 30024Toll Free: 800-433-4822www.mehvac.com Specifications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc. FORM# SLZ-KA09NA for MXZ MULTI-ZONE SYSTEMS - 201411 DIMENSIONS: SLZ-KA09NA SLZ-KA15NA SLZ-KA12NA SLZ-KA09NA Models ( 6.35mm)flared connection Refrigerent pipe(liquid)Refrigerent pipe(gas) ( 9.52mm)flared connection 3/8 inch Detail drawing of fresh air intake Ceiling surface Cut out hole2-7/8(73.4) Burring hole3-1/8(2.8) 3-15/16(100)4-21/32(118)1(25)120120+5 0(27 )+3/16 01-1/1619/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620) 22-7/16(570) 20-7/8(530) Grille Fresh airintake Drain pipeVP-25 connection(O.D.1-1/4(32)) Vane motor Drain hole Air intake grille2-5/32(55)1-3/8(35)1-3/8(35)2-5/32(55) Auto vane Grille Air intake hole Air intake holeAir outlet holeAir outlet hole11-27/32(301)11-27/32(301)14-27/32(377)14-27/32(377)25-19/32(650)Suspension bolt M10 or W3/8 9-1/16(230)7-5/32(182)1-7/8(48)Wiring entry Terminal block Ceiling surface 9-1/4(235)8-3/16(208)7-19/32(193)25/32(20)3-21/32(93)1-1/2~2-9/32(38~58)2-19/32(66)4-3/4(121)21/32(17)7-15/16(202)2-7/32(56)2-1/14(57)3-7/16(87)1-7/32(31)Ceiling holeSuspension bolt pitch19/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620)16-17/32(420)22-7/16(570)13-3/16(335)7-27/32(199) 13-27/32(352)13-3/16(335) Suspension bolt pitch Ceiling hole 25-19/32(650) Brand label V/M V/M V/M V/M 1/4 inch ( 6.35mm)flared connection 1/4 inch ( 6.35mm)flared connection 1/4 inch ( 9.52mm) flared connection 3/8 inch ( 12.7mm)flared connection 1/2 inch Refrigerantpipe (gas) Refrigerantpipe (liquid)Suspension boltlower edgeUnit : inch (mm)