cut sheets_3.pdf
6 MITSUBISHI "" ELECTRIC COOLING & HEATING • lj§i§;lfi\it.);t M-SERIES SUBMITTAL DATA: MXZ-3C30NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: Plaza Lodge Unit #7 System Reference: Job #1016 Date: 3/13/17 GENERAL FEATURES • Highly energy-efficient system that features 100% heating capacity at 5° F with guaranteed capacity down to -13° F • Quiet operation • Built-in base pan heater to prevent ice in drain pan • Limited warranty: five years parts and seven years compressors l~R ACCESSORIES o 3/8" x 1/2" Port Adapter (MAC-A454JP-E) o 1/2" x 3/8" Port Adapter (MAC-A455JP-E) o 1/2" x 5/8" Port Adapter (MAC-A456JP-E) o 1/4" x 3/8" Port Adapter (PAC-493PI) o 3/8" x 518" Port Adapter (PAC-SG76RJ-E) o M-NET Adapter (PAC-IF01 MNT-E) o Drain Socket (PAC-SG60DS-E) Outdoor Unit MXZ-3C30NAHZ o Airflow Guide (PAC-SH96SG-E) (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) Specifications Unit Tvoe Rated Capacity Btu/h Cooling* Capacity Range Btu/h (Non-<lucted I Ducted) Rated Total Input w Rated Capacity Btu/h Heating at 47°F* Capacity Range Btu/h (Non-<lucted I Ducted) Rated Total Input w Rated Capacity Btu/h Heating at 17°F* Maximum Capacity Btu/h (Non-<lucted/Ducted) Rated Total Input w Heating at 5°F* Maximum Capacity Btu/h Power Supply Voltage, Phase, Hertz Electrical Requirements Recommended Fuse/Breaker Size A MCA A Voltage Indoor -Outdoor S1-S2 v Indoor -Outdoor S2-S3 v Compressor Fan Motor (ECM) F.L.A. Sound Pressure Level Cooling dB(A) Heating External Dimensions (H x W x D) In/mm Net Weight Lbs I kg External Finish Refrigerant Pipe Size O.D. -Liquid (High Pressure) In/mm Eight Ports Gas (Low Pressure) Max. Refrigerant Line Length Ft/m Max. Piping Length for Each Indoor Unit Ft/ m Max. Refrigerant Pipe Height If IOU is Above ODU Ft/ m Difference If IOU is Below ODU Connection Method Refrigerant • Rating Conditions per AHRI Standard: Cooling I Indoor: 80° F (27°C) DB /67° F (19°C)WB Cooling I Outdoor: 95° F (35° C) DB I WB. 23.9° C (75° F) Heating at47'FI Indoor: 70° F (21°C) DB/60° F (16°C)WB Heating at 47°F I Outdoor: 47° F (8° C) DB/ 43° F (6° C) WB Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. Model Name MXZ-3C30NAHZ 28,400 / 27,400 6,000 • 28,400 2,272 I 2,661 28,600 127,600 7,200 -36,000 2,096 / 2,187 18,000 / 16,500 28,600127, 600 1,991 / 1,993 28,600 208 / 230V, 1-Phase, 60 Hz 40 30 AC 208 / 230 DC±24 DC INVERTER-driven Twin Rotary 1.9 54 58 41-9/32 x 37-13/32 x 13 1048 x 950 x 330 189 / 86 Munsell No. 3Y 7.8/11 1/4 / 6.35 A:1/2 / 12.7 ; B,C: 3/8 / 9.52 230170 82 / 25 49 / 15 49 / 15 Flared/Flared R410A Heating at 17° FI Indoor. 70' F (21° C) DB Heating at 17° FI Outdoor: 17° F (~' C) DB / 15° F (·9' C) WB SPECIFICATIONS: MXZ-3C30NAHZ, contd. Operating Range: Energy Efficiencies: Outdoor Indoor Unit Type SEER EER HSPF COP@ COP 47°F @17°F Cooling D.B. 23 to 115° F [ D.B. -5 to 46° C]*1 Non-ducted (06 + 06 + 09) 18.0 12.5 11 .0 4.00 2.65 Heating D.8. -13to 70° F[ D.B. -25to21° C) *1. D.B. Sto 115° F [ D.B. -15to46° c ], Ducted and 17.00 11.40 10.40 3.85 2.58 when an optional Air Outlet Guide is installed. Non-ducted Ducted 16.0 10.3 9.8 3.70 2.50 (09 + 09 + 09) Multi-zone Indoor/Outdoor Combination Table MSZ-FH* MSZ-GE* MFZ* MVZ* SEZ-KD* SLZ* PCA PLA* PEAD* (A24)* M:XZ-3C30NAHZ OK OK OK 12,18,24 OK OK OK OK 18,24 OK 240K 30,36 NO 12,30 NO 30, 36 NO * Refer to indoor unit submittal Notes: • Minimum of two Indoor Units must be connected to the MXZ-3C30NAHZ. • Minimum installed capacity cannot be less than 12,000 Btu/h. • System can operate with only one Indoor Unit turned on. • May connect to any style indoor unit or combination. • Information provided at 208/230V. Refer to the MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected, total connected capacity must be 100% or less. • When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). Notes: Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. MXZ-3C30NAHZ OPERATIONAL PERFORMANCE DUCTED: Operational Cooling Capacity Range (Btu/h) Performance for Indoor Heating Capacity Range (Btu/h) Unit Combinations Unit A Unit B (Unit A+ Unit B + Unit C) 9 9000 0 10900 0 12 12000 0 13600 0 15 15000 0 18000 0 18 17200 0 21600 0 24 24000 0 24000 0 9+9 9000 9000 10900 10900 9 + 12 9000 12000 9771 13029 9 + 15 9000 15000 9000 15000 9 + 18 8000 16000 8000 16000 9 + 24 6545 17455 6545 17455 12 + 12 12000 12000 12000 12000 12 + 15 10667 13333 10667 13333 9600 14400 12 + 18 9600 14400 12 + 24 8000 16000 8000 16000 15 + 15 12000 12000 12000 12000 15 + 18 10909 13091 10909 13091 18 + 18 12000 12000 12000 12000 9+9+9 9000 9000 9133 9133 9 + 9 + 12 8220 8220 8280 8280 9 + 9 + 15 7473 7473 7527 7527 9 + 9 + 18 6850 6850 6900 6900 9+12+12 7473 9964 7527 10036 9+12+15 6850 9133 6900 9200 12+12+12 9133 9133 9200 9200 Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. Power Usage Range Unit C (W) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TBD 0 0 0 0 0 0 0 0 0 9000 9133 10960 11040 12455 12545 13700 13800 9964 10036 11417 11500 9133 9200 Current (208/230V) MXZ-3C30NAHZ OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range (Btu/h) Performance for Indoor Heating Capacity Range (Btu/h) Unit Combinations Unit A Unit B (Unit A+ Unit B + Unit C) 6 6000 0 7400 0 9 9000 0 11000 0 12 12000 0 14400 0 15 14000 0 18000 0 18 17200 0 21600 0 24 22500 0 22600 0 6+6 6000 6000 7400 7400 6+9 6000 9000 7360 11040 6 + 12 6000 12000 7333 14667 6 + 15 5714 14286 6286 15714 6 + 18 5750 17250 5750 17250 6 + 24 4800 19200 4800 19200 9+9 9000 9000 11000 11000 9 + 12 8571 11429 9429 12571 9 + 15 8625 14375 8625 14375 8000 16000 9 + 18 8000 16000 9 + 24 6545 17455 6545 17455 12 + 12 11500 11500 11500 11500 12 + 15 10667 13333 10667 13333 12 + 18 9600 14400 9600 14400 12 + 24 8000 16000 8000 16000 15 + 15 12000 12000 12000 12000 15 + 18 10909 13091 10909 13091 18 + 18 12000 12000 12000 12000 6+6+6 6000 6000 7400 7400 6+6+9 6000 6000 7371 7371 6 + 6 + 12 6000 6000 7100 7100 6 + 6 + 15 5778 5778 6311 6311 6 + 6 + 18 5680 5680 5720 5720 6 + 6 + 24 4733 4733 4767 4767 Specifications are subject to change without notice. <C> 2015 Mitsubishi Electric US, Inc. Power Usage Range Unit C (W) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TBD 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6000 7400 9000 11057 12000 14200 14444 15778 17040 17160 18933 19067 Current (208/230V) I MXZ-3C30NAHZ OPERATIONAL PERFORMANCE, contd . NON-DUCTED: Operational Cooling Capacity Range (Btu/h) Performance for Indoor Heating Capacity Range (Btu/h) Unit Combinations (Unit A+ Unit B + Unit C) Unit A Unit B 6+9+9 6000 9000 7100 10650 6 + 9 + 12 5778 8667 631 1 9467 6 + 9 + 15 5680 8520 5720 8580 6 + 9 + 18 5164 7745 5200 7800 6 + 12 + 12 5680 11360 5720 11440 6+12+15 5164 10327 5200 10400 6+12+18 4733 9467 4767 9533 6 + 15 + 15 4733 11833 "'""""'7 9+9+9 8667 8667 9467 9467 9 + 9 + 12 8580 8580 9 + 9 + 15 7745 7745 7800 7800 9 + 9 + 18 7100 7100 7150 7150 9 + 12 + 12 7745 10327 7800 10400 9+12+15 7100 9467 7150 9533 12+12+12 9467 9467 9533 9533 Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. Power Usage Range Unit C (W) 9000 10650 11556 12622 14200 14300 15491 15600 11360 11440 12909 13000 14200 14300 11833 TBD ""n-t"7 8667 I 9467 11440 12909 13000 14200 14300 10327 10400 11833 11917 9467 9533 Current (208/230V) DIMENSIONS: MXZ-3C30NAHZ Side Air Intake¢ N "' "' "' •1-3/32'punched hole 6-•1-5/16' Drain Hal 1Connect1ng wire hotel 2-'7 /8'punched hole 2-15/16' <Connect1nn wire holel 2-3/32" Ii 3-•7/8"knockoul hole ~~ (Connecting wire holel ~ .c::JCil CJCH u I CJCD Handle CJCD • .I ~ h: Ii Bia ~~1~1 EJEH ~";' rr;i CJCD :AN~ CJCH "' ~L CJCD "' CJOJ "' CJCH r c=JCil N -~ "' ~ 1.FREE SPACE ~ 3-15/16' or more I!> 3-15/16' or more 2.SERVICE SPACE 3-15/16' or more A.~~= CERTIFIED --~ 1 I II•) ,'IJ-F,' 1 .. ' . ..,, lntertek FORM# MXZ-3C30NAHZ for Multiple Indoor Unit Styles -201505 Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc. -7/8' 23-518' ,,_7/32' 2-U Shaped Notched Hole <Foundahan Boll M10l "' "' 2-(15/32'X1-13/32'1 Oval Hole <Foundation Bolt M101 31132" 19/32' Lock nut Conduit plate Top Unit: inch (mm) • MITSUBISHI ...... ELECTRIC COOLING & HEATING 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com