Loading...
HomeMy WebLinkAboutB16-0144_MP.211_1478906557.pdfLV 5 LV 5 LV 5 WC 6 WC 6 SH 7 BT 8 KS 9 DW 11 IM 12 (E) FP LV 5 CWB 10 INSTALL EXHAUST FAN WITH CEILING RADIATION DAMPER IN LOCATION SHOWN ON ARCHITECTURAL PLAN & RECONNECT TO THE EXISTING 4"Ø EXHAUST DUCT ABOVE THE CEILING. IF EXISTING DUCT IS IN POOR CONDITION OR HAS BEEN REMOVED DURING DEMOLITION, INSTALL NEW DUCT. CONNECT 6"Ø DUCT TO THE NEW MICROWAVE/HOOD COMBO. THE HOOD SHALL NOT EXCEED 400 CFM. FIREPLACE FLUE PER FIREPLACE CONTRACTOR. INSTALL 4"Ø DRYER VENT ABOVE FIRE RATED CEILING. THE DUCT SHALL BE WRAPPED WITH 3M FIRE BARRIER DUCT WRAP, OR EQUAL, FROM THE CEILING PENETRATION TO THE EXTERIOR WALL PENETRATION TO MAINTAIN THE REQUIRED FLOOR/CEILING ASSEMBLY FIRE RATING. TOTAL EQUIVALENT LENGTH OF THE DRYER DUCT SHALL NOT EXCEED 35' AS MEASURED BY THE INTERNATIONAL MECHANICAL CODE, OR SHALL NOT EXCEED THE LENGTH SPECIFIED BY THE MANUFACTURER'S REQUIREMENTS. CONNECT 1 2" CW, 1 2" HW, 1 1 2" W & 1 1 2" V TO LV. CONNECT 1 2" CW, 3" W & 2" V TO WC. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO SH. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO BT. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO KS. CONNECT 3 4" CW, 3 4" HW, 2" W & 1 1 2" V TO CWB. CONNECT 1 2" HW & 1 1 2" W TO DW. INSTALL INDIRECT WASTE CONNECTION TO THE KITCHEN SINK PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONNECT 1 2" CW TO IM. CONNECT 3 8" CW TO SS-1. MAINTAIN CLEARANCE'S PER MANUFACTURER'S INSTRUCTIONS. DO NOT RUN THE STEAM LINE DOWN AND THEN UP AS THIS WILL CREATE A STEAM TRAP BLOCKING THE FLOW OF STEAM. PROVIDE ACCESS PANEL FOR SERVICING. CONNECT 3 4" CW TO PF. INSTALL 6"Ø KITCHEN EXHAUST DUCT ABOVE THE FIRE RATED CEILING. THE DUCT SHALL BE WRAPPED WITH 3M FIRE BARRIER DUCT WRAP, OR EQUAL, FROM THE CEILING PENETRATION TO THE EXTERIOR WALL PENETRATION TO MAINTAIN THE REQUIRED FLOOR/CEILING ASSEMBLY FIRE RATING. IF 4"Ø CANNOT ROUTE BENEATH THE BEAM AT THIS LOCATION, TRANSITION TO A 6" X 3". MAINTAIN CLEARANCES OF 3FT FROM OPERABLE OPENINGS & 10FT FROM MECHANICAL AIR INTAKES. CONNECT 1 2" CW TO WF. PROVIDE WASTE CONNECTION IF REQUIRED BY MANUFACTURER. 9 10 11 SPECIFICATIONS: 1. REFER TO THE BOOK SPECIFICATIONS FOR THE BASE BUILDING PROJECT. 12 13 14 15 16 GENERAL NOTES: 1. THE EXISTING BATH EXHAUST FANS SHALL BE REMOVED, UNLESS NOTED OTHERWISE. 2. EXISTING PLUMBING FIXTURES SHALL BE REMOVED DURING DEMOLITION, UNLESS NOTED OTHERWISE, AND THE ASSOCIATED PIPING SHALL BE CAPPED FOR RECONNECTION. THE PLUMBING CONTRACTOR SHALL ROUTE THE PIPING TO THE NEW FIXTURES AS REQUIRED AND CONNECT THE PIPING SIZE NOTED. ALL NEW HOT AND COLD WATER PIPING FOR EACH BATHROOM GROUP AND KITCHEN SHALL ORIGINATE FROM THE LARGEST PIPE SIZE AVAILABLE. DO NOT ROUTE LARGER PIPES FROM SMALLER PIPES. 3. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 4. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 5. ALL DUCTWORK AND PIPING SHOWN DASHED IS EXISTING OR COMPLETED AS PART OF THE BASE BUILDING SCOPE OF WORK. SHEET DETAIL NOTES: 2 3 4 EF 1 1 EF 1 1 16 4"Ø 16 6"Ø 4"Ø 6"Ø 15 17 17 17 8 7 6 5 4 3 2 1 4"Ø SS 1 PF 14 WF 18 18 13 EAST BUILDING LIONSHEAD PLACE VAIL, COLORADO LION SQUARE LODGE Fax: 970-748-8521 Architectural EngineeringCGE Eagle-Vail, Colorado, 81620 Telephone: 970-748-8520 PO Box 8489 40801 US Hwy 6 & 24, Ste 214 Mechanical, Electrical & Lighting Design Services Consultants, Inc. An Office with LEED Accredited Professionals TMNORTH UNIT 211 HVAC PLAN SCALE: 1/4" = 1'0" NORTH UNIT 211 PLUMBING PLAN SCALE: 1/4" = 1'0" MP.211 UNIT 211 SCHECK 08/15/16