Loading...
HomeMy WebLinkAboutB16-0149_2.2A7-R_1478899482.pdf1 2 3 A B A7-R 5 Mens - West 2 Mens - North 3 Mens-East 4 Mens - South Concrete Fl ELEC HAND DRYER ELEC UNIT HEATER 16" A.F.F., CENTER IN ROOM 1' - 6 1/2" 2' - 9 5/8" 0' - 3 1/2" 2' - 7 5/8" 0' - 0 3/4" 5' - 1 1/2" 0' - 5 1/2" 5' - 0" 5' - 0" GRAB BARS, PROVIDE BLOCKING IN WALL GRAB BARS, PROVIDE BLOCKING IN WALL COUNTERTOP & SINK AT 34" A.F.F. URINAL ADA W.C . 1' - 4 3/8" 5' - 0" FD 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 0' - 4 5/8" 2' - 10 3/4" 0' - 6" 3' - 0" 1' - 1" 2' - 11" 0' - 5 11/32" 2' - 4" TP HOLDER 2' - 11 3/4" 2' - 8" 4' - 0" 2 2 A5.1-R 1 A5.1-R MDF MDF TILE 4' - 1 1/2" PARTIAL HEIGHT WALL W/ FRP, CORNER, EDGE TRIM 3 A5.1-R B 2 A5.1-R 2' - 10 1/32" 4' - 1 1/2" GRAB BARS, PROVIDE BLOCKING IN WALL MDF TILE SOLID SURFACE PARTITION PARTIAL HEIGHT WALL, FRP CORNER, EDGE TRIM GLU-LAM BEAM PER STRUCTURAL MIRROR 8' - 0" 7' - 9" 2 MDF CEILING MDF TILE SOLID SURFACE PARTITION B MDF TILE 1' - 4" 1' - 8" 3' - 5 1/4" UNIT HEATER A.1 B.1 2.1 3.1 A7-R 7 1 - a 101 - d 9 1 - c 8 1 - b WOMEN 102 Concrete Fl ELEC HAND DRYER ELEC. UNIT HEATER 16" A.F.F., CENTER IN ROOM FD 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 5' - 0" 5' - 0" 1' - 6 1/2" 0' - 5 1/2" 5' - 0" 0' - 5 1/2" 2' - 9 1/2" 0' - 3 1/2" 2' - 7 3/4" 0' - 0 3/4" 5' - 1 1/2" 0' - 5 1/2"2' - 11 3/4" 2' - 8" 2' - 4" 0' - 5" 2' - 10 3/4" 0' - 4 1/4" 2' - 0" 0' - 4 1/4" COUNTERTOP & SINK AT 34" A.F.F. 1' - 4 3/8" ADA W.C. GRABBARS PROVIDE BLOCKING 8' PARTITION W/ TILE FINISH 0' - 6" 2' - 11" 1' - 1" 0' - 6" 3' - 0"B.1 MDF. TILE GLU-LAM BEAM 2.1 MDF. MDF. TILE SOLID SURFACE PARTITION GLU-LAM BEAM PER STRUCTURAL MDF TILE MIRROR 3' - 0" 4' - 0" 2' - 10" 2.1 MDF. TILE SHEET NUMBER 1309 ELKHORN DRIVE . VAIL . COLORADO. 81657 970.479.2158 P.O. Box 445 Edwards, CO 81632 ph 970.926.2622 cell 970.471.0667 Ann@DarbyArchitects.com DARBY ARCHITECTS,p.c. DESIGNWORKSHOP Landscape Architecture . Land Planning 120 E. Main St. Aspen, CO 81611 (970) 925-8354 Facsimilie (970) 920-1837 W W W . D E S I G N W O R K S H O P . C O M # DATE DESCRIPTION ISSUE DATE REVISIONS DRAWN: REVIEWED: 4/4/2016 3:31:29 PM A7-R BOOTH CREEK PARK RESTROOMS 2900 MANNS RANCH ROAD VAIL. COLORADO PERMIT SET 3-25-2016 Author Checker 1505 1/2" = 1'-0" 1 Men's Restroom - Enlarged Plan 1/2" = 1'-0" 2 Mens - North 1/2" = 1'-0" 3 Mens-East 1/2" = 1'-0" 4 Mens - South 1/2" = 1'-0" 5 Mens - West 1/2" = 1'-0" 6 Women's Restroom - Enlarged Plan 1/2" = 1'-0" 7 1 - a 1/2" = 1'-0" 8 1 - b 1/2" = 1'-0" 9 1 - c 1/2" = 1'-0" 10 1 - d 08/19/16