HomeMy WebLinkAboutB16-0149_6E2.1_1478906674.pdf1. EXTERIOR LIGHTING SHALL BE CONTROLLED BY
LIGHTING CONTROL PANEL (LCP).
2. NUMBERS ADJACENT TO DEVICES AND EQUIPMENT
INDICATE CIRCUIT IN PANEL
NOTES:
LIGHTING CONTROL PANEL (LCP). RE: A/E1.0 FOR
LIGHTING CONTROL PANEL DIAGRAM.
PROVIDE WATTSTOPPER ULTRASONIC LINE
VOLTAGE CEILING SENSOR.
PROVIDE WATTSTOPPER PASSIVE INFRARED
WALL SWITCH.
PROVIDE ELECTRICAL CONNECTION TO AUTOMATIC
PLUMBING FIXTURES.
FLAG NOTES:
SCALE:
RESTROOM ELECTRICAL PLAN
1/4" = 1'-0"
PANEL 'P1'
W1
W1
W1
W1
W2
W2
S1 S1
S1
S1
S1
LUMINAIRE SCHEDULE
TYPE DESCRIPTION MOUNTING LUMENS LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER
SPECIFIC
NOTES
QTY TYPE
W1 4FT WALL MOUNTED LED VANDAL RESISTANT SURFACE
FIXTURE, VERIFY FINISH WITH ARCHITECT
SURFACE 2080 -- LED AS SUPPLIED,
3500K
30 UNV PHILIPS LPLS4L30-35K-UNV-F1
W2 2FT WALL MOUNTED LED VANDAL RESISTANT SURFACE
FIXTURE, VERIFY FINISH WITH ARCHITECT
SURFACE 2200 -- LED AS SUPPLIED,
3500K
30 UNV PHILIPS LPLS2L30-35K-UNV-F1
S1 5" ROUND, LOW PROFILE, SURFACE MOUNTED LED
DOWNLIGHT
SURFACE 650 -- LED AS SUPPLIED,
2700K
9.5 120 PHILIPS S5R827K7AL
GENERAL NOTES:
A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE
PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND
SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING.
B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS.
C. ALL FLUORESCENT LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE
SPECIFIC NOTES:
(1)
(2)
(3)
(4)
1
1
OS
OS
2
2 2
S
O
S O
3
3
3
MECHANICAL EQUIPMENT SCHEDULE
MARK DESCRIPTION VOLT /
PHASE
HP WATTS FLA DISCONNECT/
FUSE SIZE
FEEDER SPECIFIC NOTES
BB-1 BASEBOARD HEATER 120/1 -- 500 4.2 1P MOTOR RATED
SWITCH
(2#12 & 1#12G) 3/4"C
UH-1 UNIT HEATER 120/1 -- 1500 12.5 1P MOTOR RATED
SWITCH
(2#12 & 1#12G) 3/4"C
WH-1 TANK ELECTRIC WATER
HEATER
120/1 -- 2000 29 2P MOTOR RATED
SWITCH
(2#10 & 1#10G) 3/4"C
BB
1
BB
1
WP
WP
+48"
+48"
+48"
+48"
J
J
J
J
4
4
4
4
4
CONTROLLED
BY LCP
SCALE:
PICNIC ELECTRICAL PLAN
1/4" = 1'-0"
UH
1
UH
1
WP WP
13
13
13
13
WH
1
7
7
7
9
11
11
11
11
4
3
8
8
8
2
1
11
11
10
10
2-#10, #10 GRD
TO IRRIGATION CONTROLLER
C
DATE # DESCRIPTION
ISSUE DATE:
SHEET NUMBER
REVIEWED:
PROJECT NUMBER:
DRAWN:
1
REVISIONS
5431
2 3 4 5 6 7
A
B
C
D
E
REDEVELOPMENT
2900
MANNS
RANCH
ROAD
VAIL,
COLORADO
C O P Y R I G H T D E S I G N W O R K S H O P, I N C.
F
8 9
1 2 3 4 5 6 7 8 9
CONSTRUCTION
DOCUMENTS
March 25, 2016
BOOTH
CREEK
PARK
1309 ELKHORN DRIVE. VAIL, COLORADO. 81657
970.479.2158
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www˛bgbuildingworks˛com
Project No. 9667.00 Copyright 2016
E2.1
RESTROOM
ELECTRICAL
PLAN
BAS MAS