HomeMy WebLinkAboutB16-0149_6M2.1_1478899547.pdf4" PLUMBING VENT THROUGH SIDEWALL, 10' ABOVE GRADE. PROVIDE WITH BIRD SCREEN. TERMINATE PER 2009 IPC RQT'S. 1 FLAG NOTES: SCALE: 1 RESTROOM MECHANICAL PLAN 1/4" = 1'-0" P1 P5 P5 P3 P2 P2 P2 P5 P1 P4 P7 WATER SERVICE. RE: B/M2.1 FFI. DOMESTIC WATER SERVICE, I.E.=8316' A.S.L., MINIMUM 4' BELOW FINAL GRADE. RE: CIVIL FOR CONTINUATION. P8 MOUNTED HIGH ON WALL SHELF. RE: A/M2.1 FFI. P6 W W CW FD WC WC LAV DF DF LAV MS FS FD UR FD WC WCO 4" W EXIT WCO SCALE: 2 WASTE & VENT ISOMETRIC NONE SCALE: 3 DOMESTIC WATER ISOMETRIC NONE W WW W 4"W EXIT, I.E.=8316' A.S.L., MINIMUM 4' BELOW FINAL GRADE. RE: CIVIL FCT. WC WC H/C HB LAV EH (EXTERIOR) DF MS LAV UR WC CW WATER ENTRY LOW POINT, MEN'S RESTROOM SIDE. SLOPE PIPES TO DRAIN VALVE. LOW POINT, WOMEN'S RESTROOM SIDE. SLOPE PIPES TO H/C HOSEBIB. SLOPE FROM HIGH POINT ABOVE WH TO HOSE END DRAINS. WH WOMEN'S RESTROOM BLGD. MEN'S RESTROOM BLGD. 2" 2-1/2" 1 1 IN WALL 16" A.F.F. 1 1 IN WALL 16" A.F.F. P9 PIPING THROUGH UN-HEATED ROOF TO BE INSULATED TO EXTERIOR PIPING RQT'S.; PROVIDE WITH HEAT TAPE THROUGH ENTIRE EXTERIOR RUN. EXTEND HEAT TAPE AND EXTERIOR-LEVEL INSULATION 12" INTO INTERIOR HEATED SPACE 4" 2" 2" 4" 4" 1" 1 - 1/4 " 1-1/2" 1-1 / 4" 1" 1" 1" 3 /4" 1" 1. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, ELECTRICAL, FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS. 2. AVOID ROUTING DUCTWORK OR PIPING OVER OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 3. VERIFY ALL EQUIPMENT ACCESS WITH MANUFACTURER AND ARCHITECT. 4. PROTECT PIPING ROUTED ALONG COLUMNS, WALLS, ETC. FROM DAMAGE AS NECESSARY WITH CAGES. COORDINATE WITH ARCHITECT. 5. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED. 6. EXHAUST FAN TO OPERATE UPON DETECTION OF OCCUPANCY BY ELECTRICAL-PROVIDED OCCUPANCY SENSOR FOR COMBINED LIGHTING AND EXHAUST CONTROL. COORDINATE CONTROLS WITH ELECTRICAL AND LIGHTING. EXHAUST FAN TO CONTINUE TO OPERATE 10 MIN (ADJ) AFTER LAST DETECTED OCCUPANCY. 7. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 8. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS, AND ELECTRICAL. 9. REFER TO THE PLUMBING FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 10. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER. 11. INSTALL THERMOSTATIC MIXING VALVES, ASSE 1070 LISTED, AT EACH PUBLIC HANDWASHING LAVATORY/SINK. SIZE TO MATCH HW PIPE SIZE. 12. WINTERIZATION: ALL FREEZE-PRONE SYSTEMS SHALL BE CONSTRUCTED TO FACILITATE COMPLETE SEASONAL DRAIN DOWN. HVAC NOTES: EAGLE RIVER WATER ENTRANCE DIAGRAM M NO SCALE DOMESTIC WATER SERVICE SHUT-OFF VALVE. 1-1/2" CW TO BLDG. 1-1/2" REDUCED PRESSURE TYPE BACKFLOW PREVENTER. CERTIFIED TESTER TO TEST. 1" WATER METER WITH REMOTE READOUT. PRESSURE REDUCING VALVE, WATTS 223, 3/4" SET @ 60 PSI CW SERVICE ENTRY FROM UTILITY. : 1. WATER METER AND BACKFLOW PREVENTER MUST BE MOUNTED HORIZONTALLY. 2. METER, SHUT-OFF, AND BYPASS LOCATED IN METER PIT. BACKFLOW PREVENTER LOCATED IN WATER ENTRY CLOSET AT MEN'S RESTROOM. METER BYPASS. D PIPING DIAGRAM DOMESTIC WATER HEATER FLOOR D S NO SCALE SUPPORT FROM STRUCTURE. TEMPERING VALVE. COLD WATER SUPPLY. DIAPHRAGM TYPE EXPANSION TANK. AMTROL ST-8. PIPE RELIEF VALVE INDIRECT TO DRAIN PAN. TERMINATE 1-1/2" ABOVE DRAIN PAN. SHELF WITH SAFE PAN, DRAIN PIPE FROM SAFE PAN TO EXTEND & SPILL 6" ABOVE MOP BASIN OR FLOOR DRAIN. HW TO MEN'S. WATER HEATER MOP BASIN 3/4" (ELECTRIC) SLOPE CW PIPE SERVING BUILDING BACK TO DRAIN-DOWN VALVE WITH HOSE END LOCATED IN WATER ENTRY CLOSET FOR SEASONAL BUILDING DRAINAGE. HW TO WOMEN'S. VENT HIGH POINTS. METER PIT ENTRY CLOSET A B WATER HEATER DRAIN POINT. C DATE # DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 5431 2 3 4 5 6 7 A B C D E REDEVELOPMENT 2900 MANNS RANCH ROAD VAIL, COLORADO C O P Y R I G H T D E S I G N W O R K S H O P, I N C. F 8 9 1 2 3 4 5 6 7 8 9 CONSTRUCTION DOCUMENTS March 25, 2016 BOOTH CREEK PARK 1309 ELKHORN DRIVE. VAIL, COLORADO. 81657 970.479.2158 ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9667.00 Copyright 2016 RESTROOM MECHANICAL PLAN M2.1 08/19/16