Loading...
HomeMy WebLinkAboutB16-0149_S9_1478907828.pdf97'-0" 99'-0" 100'-0" 96'-0" PT 2x6 STUDS @ 16" w/ PT 7/16 OSB SHEATHING w/ 3" STONE VENEER w/ HB-213, 12 Ga TWO PIECE ADJUSTABLE WIRE TIES @ 16” VERT ALONG EA STUD COORDINATE OPENING w/ ARCH (24"Ø MAX) (3) 2x8 HEADER SIMPSON HDU2-SDS2.5 w/ 5/8"Ø GALV ANCHOR BOLT w/ 6" EMBEDMENT AT EACH CORNER OF CHIMNEY 12" SURFACING PER ARCH FOOTING, SEE PLAN CONC PEDESTAL, SEE 11/S3 107'-6" 112'-6 1/4" 4" BRICK LEDGE PT 2x6 SILL PL w/ GALV 1/2"Øx10" ANCHOR BOLT @ 24", BUILD UP PL PER ARCH TO ACCOMODATE OPENING 150.00° 2'-1 3/8" 4'-0" 2'-1 3/8" 1'-0" 2'-0" 1'-0" 109'-2 3/4" (3) 2x8 HEADER 108'-1 3/4" 150.00° 11 13 8'-2 3/4" 3" STONE VENEER 4'-0" SHEET NUMBER 1309 ELKHORN DRIVE . VAIL . COLORADO. 81657 970.479.2158 # DATE DESCRIPTION ISSUE DATE REVISIONS DRAWN: REVIEWED: 7/27/2016 10:36:08 AM S9 BOOTH CREEK PARK 2900 MANNS RANCH ROAD VAIL, CO 81657 CONSTRUCTION DOCUMENTS ADDENDUM - 3 4/22/2016 Author Checker 17831 0 6" 1' 2' 3' 3/4" 3/4" = 1'-0" S9 CHIMNEY ELEVATION - LOOKING NORTH 1 1 1 7/20/2016 Revision 1 – Cabin Chimney 7/20/2016 08/03/16