HomeMy WebLinkAboutB16-0180_A1_1478902005.pdf5 1/2" 8' - 1" 7' - 10" EXISTING CONCRETE SLAB "WARMBOARD" PROPRIETARY IN-FLOOR HOT WATER RADIANT HEATING SYSTEM 1 1/8" THICKNESS WOOD FLOORING 3/4" THICKNESS (SELECTION BY OWNER) SECOND LEVEL UNIT FLOORING MATERIAL UNKNOWN EXISTING PLYWOOD SHEATHING EXISTING STEEL BAR JOISTS RECESSED CEILING LIGHT FIXTURE SELECTION BY OWNER / CONTRACTOR. "TENMAT" PROPRIETARY CERAMIC FIRE RATED LIGHT COVER. 1-HR FIRE RATING - UL LISTED. ALTERNATIVE: 5/8" TYPE "X" DRYWALL "BOX" OR RATED LIGHT FIXTURE. CEILING FIRE-RATED ASSEMBLY NOTE: 5/8" TYPE "X" DRYWALL HUNG ON 1/2" RESILIANT SOUND-MITIGATION HAT CHANNELS. SEE GA FILE 2030 2-HR RATED ASSEMBLY FOR "SIMILAR" ASSEMBLY. UL LISTED 1-HR ASSEMBLY CANNOT BE REASONABLY ACHIEVED WITHIN EXISTING CONSTRUCTION. PARTY WALL FIRE-RATED ASSEMBLY NOTE: 5/8" TYPE "X" DRYWALL ATTACHED TO EXISTING WOOD STAGGERED STUD PARTY WALL. RUN DRYWALL FROM CONC. FLOOR TO SHEATHING OF FLOOR ABOVE. CUT DRYWALL TIGHTLY AROUND STEEL JOISTS. SEE GA FILE WP 3380 1-HR RATED ASSEMBLY FOR "SIMILAR" ASSEMBLY. UL LISTED 1-HR ASSEMBLY CANNOT BE REASONABLY ACHIEVED WITHIN EXISTING CONSTRUCTION. 3 1/2" UNIT 103 FLEXIBLE SEALANT STUFF 11" UNFACED BATT INSULATION INTO CEILING SPACES FOR NOISE MITIGATION. SPRAY-FOAM STUD CAVITY FOR SOUND MITIGATION AND AIR-INFILTRATION. 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 6/23/2016 8:51:27 AM 121 W Meadow Dr #A103 Vail, Colorado A1 COVER SHEET xxxx FULLER RENOVATION PERMIT SET 4-21-16 4-21-16 FULLER FULLER RENOVATION ALPENHORN CONDOS A103 PROJECT NARRATIVE THE CONDO UNIT HAS BEEN GUTTED DOWN TO WOOD STUDS. THE OWNER PROPOSES AN IMPROVED CUSTOM WALL LAYOUT. ALL ELECTRICAL AND PLUMBING WILL BE REPLACED AND/OR IMPROVED. ALL NEW APPLIANCES, FIXTURES, AND FINISHES ARE PROPOSED. Owner: Steven M. Pesso 4800 N. Federal Hwy. Su. E302 Boca Raton, FL 33531 Spesso@aol.com Cell: 561-212-9544 Location: 1030 Lions Ridge Loop #304 (Lions Ridge Filing #1 ) Vail, Colorado 81658 Parcel # 2103-014-16-014 Class of Work: Alteration / Renovation Type of Construction: Type V-a Non-sprinklered Type of Occupancy: R1 (original) R2 (current code) Levels: 3-Story ALSO SEE BUILDING CODE NOTES THIS SHEET Architect: John G Martin, AIA Martin Manley Architects www.martinmanleyarchitects.com john@martinmanleyarchitects.com 970-328-1299 PROJECT INFORMATION Structural Engineer: Not Required General Contractor: T. Horn Enterprises Inc. PO Box 552 Edwards, CO 81632 Zoning Summary: All work will be completed within existing unit space. Exterior window upgrades will require HOA approval. No DRB submittal or approval necessary. THE CONDO UNIT HAS ALREADY BEEN DEMOLISHED. ALL DRYWALL AND ASBESTOS HAS BEEN REMOVED. ONLY WOOD STUDS REMAIN. THE UNIT SEPERATION FIRE-RATINGS HAVE BEEN COMPROMISED. ALL FIXTURES AND EQUIPMENT HAVE BEEN REMOVED OR ARE GOING TO BE REMOVED. MOST OF THE WOOD STUD WALLS ARE GOING TO BE REMOVED AS WELL. A FEW WOOD STUD WALLS WILL REMAIN IN PLACE. SEE FLOOR PLANS FOR EXISTING AND NEW WALL LOCATIONS. THE BEDROOM WINDOWS WILL REMAIN UNTOUCHED. IF THE WINDOWS ARE CHANGED DURING CONSTRUCTION THEN THEY MUST MEET EGRESS REQUIREMENTS OF THE 2015 IBC AND MEET HOA REQUIREMENTS FOR MATCHING EXISTING WINDOWS. THE LIVING ROOM WINDOWS AND DOORS WILL BE UPGRADED IN QUALITY BUT REMAIN WITHIN THE EXISTING SIZE OPENINGS OF THE EXTERIOR WALL. THE UPGRADED ALUMINUM CLAD WINDOWS MUST MATCH EXISTING COLORS AND BE APPROVED BY THE HOA. ANY NEW WINDOW OR DOOR MUST MEET THE IBC 2015 MAXIMUM U-VALUE OF .30. A NEW FRONT DOOR MUST BE APPROVED BY THE HOA. ALL NEW INTERIOR FINISHES AND COLORS ARE TO BE SELECTED AND APPROVED BY THE OWNER. THE EXISTING WOOD BURNING FIREPLACE MUST NOT BE ALTERED EXCEPT FOR AESTHETIC SURFACE MATERIAL UPGRADES. IF ANY ALTERATION IS PROPOSED DURING CONSTRUCTION, A STRUCTURAL ENGINEER MUST BE RETAINED AND ALL CHANGES ENGINEERED. ALSO ALTERATIONS MAY REQUIRE THE LOSS OF THE WOOD-BURNING FIREPLACE AND A HIGH-EFFICIENCY OR GAS APPLIANCE FIREPLACE MUST BE PROPOSED AND APPROVED BY THE TOWN OF VAIL, IN IT'S PLACE. MUCH OF THE PLUMBING WITHIN THE COMMON WALLS IS HIGH-QUALITY COPPER PIPING WHICH IS AN APPROVED MATERIAL FOR 1-HR RATED ASSEMBLY WALLS. ALL NEW PLUMBING MUST ALSO BE HIGH-QUALITY COPPER PIPING WITHIN COMMON WALLS. AN EXISTING CHASE FOR LAUNDRY EXHAUST WILL BE RE-USED FOR THE NEW STACKABLE W/D IN APPROX. SAME LOCATION. THE PENETRATION MUST BE SEALED PER CODE. AN EXISTING CHASE FOR THE MECHANICAL EXHAUST AND AIR-INTAKE WILL BE ABANDONED. THE CHASE OPENING WILL BE COVERED AND MEET SAME FIRE RATING DETAIL AS THE SURROUNDING LID. A HIGH-EFFICIENCY WALL-MOUNTED BOILER WILL BE SELECTED BY THE OWNER/CONTRACTOR. THE AIR INTAKE AND EXHAUST PVC PIPES WILL RUN THROUGH THE CEILING JOIST SPACE HORIZONTALLY TO THE REAR WALL AND EXHAUST AT A LOCATION APPROVABLE BY THE HOA AND THE BUILDING OFFICIAL. MINIMIUM CLEARANCES TO OPERABLE WINDOWS MUST BE ACHIEVED. THE WATER HEATER WILL BE A SIDE-ARM WATER TANK (HEATED USING THE BOILER) OR A PROPRIETARY WATER HEATER SELECTED BY THE OWNER/CONTRACTOR AND APPROVED BY THE TOWN OF VAIL. AN EXISTING STRUCTURAL POINT-LOAD WOOD-STUD GANGED POST LOCATED ALONG THE REAR EXTERIOR WALL HAS BEEN COMPROMISED WITH A CUT-IN PLUMBING PIPE. STRENGHTEN PER STRUCTURAL ENGINEER - KRM CONSULTANTS MEMO DATED 6-22-16. CONSTRUCTION NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 10. ALL WORK MUST BE COMPLETED IN ACCORDANCE WITH THE 2015 EDITIONS OF THE "INTERNATIONAL BUILDING CODE" (IBC), "INTERNATIONAL PLUMBING CODE", "INTERNATIONAL FUEL GAS CODE", "INTERNATIONAL ENERGY CONSERVATION CODE" (IECC), "INTERNATIONAL FIRE CODE", THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE, AND TOWN OF VAIL ORDINANCE SERIES 2015 FOR ADOPATION OF THE ABOVE LISTSED CODES. BASED ON REVIEW OF THE EXISTING DRAWINGS, THE EXISTING BUILDING WAS CONSTRUCTED AS A NON-CONFORMING TYPE V 1-HR BUILDING. ALL NEW WORK WILL BE COMPLETED IN ACCORDANCE WITH THE REQUIREMENTS OF A TYPE V-a CONSTRUCTION CLASSIFICATION. IT IS ASSUMED THAT THIS PORTION OF THE EXISTING BUILDING WAS CLASSIFIED AS AN R-1 OCCUPANCY WHEN IT WAS CONSTRUCTED. UNDER THE PRESENT CODE IT IS CLASSIFIED AS AN R-2 OCCUPANCY. ALL NEW WORK WILL BE COMPLETED IN ACCORDANCE WITH THIS CLASSIFICATION. THE EXISTING BUILDING IS (3) STORIES TALL AND THE BUILDING HEIGHT WILL NOT BE INCREASED WITH THE PROPOSED WORK. THIS UNIT IS LOCATED ON THE FIRST STORY. SHOULD ANY PENETRATIONS OF NEW WALL ASSEMBLIES AND FLOOR / CEILING ASSEMBLIES BE REQUIRED DURING THE CONSTRUCITON PROCESS, THEY ARE TO BE SEALED IN ACCORDANCE WITH THE "IBC" AND WITH U.L. APPROVED ASSEMBLIES. REFER TO GENERAL CONSTRUCTION NOTES AND CONSTRUCTION DESCRIPTION NOTES FOR ADDITIONAL SPECIFIC CODE RELATED INFORMATION. REFER TO FIRE RESISTIVE RATED ASSEMBLIES LOCATED IN THIS DRAWING SET. 1. 2. 3. 4. 5. 6. 7. BUILDING CODE NOTES: 1" = 1'-0" 1 WALL SECTION PROVIDE THE NEW ELECTRICAL OUTLETS AND LIGHT FIXTURES CONTROLLED BY SWITCHING INDICATED ON THE PROPOSED REFLECTED CEILING PLAN WITH THE NEW LIGHT FIXTURES TO COMPLY WITH INTERNATIONAL ENERGY CONSERVATION CODE (IECC) SECTION C402.4.8 FOR METHOD OF INSTALLATION AND WILL RECIEVE HIGH EFFICIENCY LAMPS. NEW ELECTRICAL DEVICES AND INTERIOR LIGHTS ARE TO BE APPROVDED BY THE OWNER. VERIFY LOCATIONS OF ALL ELECTRICAL DEVICES AND LIGHT FIXTURES WITH THE OWNER AFTER INSTALLATION OF ROUGH-IN BOXES AND PRIOR TO INSTALLING WIRING. THE ELECTRICAL BOX IS BEING MOVED AND ALL OF THE ELECTRICAL WIRING IS BEING REPLACED AND/OR UPGRADED. ELECTRICAL ENGINEERING STAMPED DRAWINGS AND LOAD CALCULATIONS MUST BE SUBMITTED WITH THE BUILDING PERMIT SUBMITTAL. 9. GENERAL ELECTRICAL NOTES: E1. E2. 11. Fire Suppression Notes: The unit does not currently have an automatic sprinkler system. No sprinkler system is proposed. Wired smoke detectors will be installed per UBC 1015 requirements. General contractor to verify with the Town of Vail fire dept. that an automatic sprinkler system and monitored smoke detectors will not be required. Sheet List Sheet Number Sheet Name A1 COVER SHEET A2 FLOOR PLAN & RCP VAIL CORE - VICINITY MAP EXTERIOR PHOTO BUILDING LOCATION RATED ASSEMBLIES AND PRODUCTS No. Description Date 1 Revision 1 6-23-16 x 1 07/26/16