1' - 0"
BEDROOM 1 BEDROOM 2
(BUNK ROOM)
BATH 1
BATH 2
MECH.
ENTRY
W/D
PANTRY
CABINET
COATS
UTIL.
CLOSET
NEW ELECTRICAL
BOX LOCATION
0 1 5 10
PROJECT
NORTH
EXISTING 2X4 WALL (TYP)
NEW 2X4 WALL (TYP)
1
1
WINDOWS TO REMAIN UNTOUCHED 2
WINDOWS TO BE REPLACED FRONT DOOR TO BE REPLACED
3 3
NEW FLOORING AND
OTHER FINISHES TO BE
SELECTED BY
OWNER/CONTRACTOR.
4
WOOD BURNING
FIREPLACE TO
REMAIN W/ NEW
FINISHES
5
SEE PLUMBING NOTE
6 SEE DRYER
VENT NOTE
7
SEE MECH.
CEILING NOTE
8
SEE MECH.
NOTES 9 10
SEE POINT-
LOAD NOTE
11
25' - 0"
5 1/2" 10' - 9" 3 1/2" 2' - 0" 3 1/2" 10' - 9" 5 1/2"
5' - 2" 3 1/2"
3' - 3" 3' - 1" 2' - 7" 3' - 5" 3 1/2" 3' - 4" 2' - 8"
2' - 0"
E2
5' - 2"
5 1/2" 4' - 2" 2' - 7" 11' - 4" 3 1/2" 5' - 1" 3 1/2" 15' - 4"
40' - 0"
3' - 9" 4' - 9 1/2"
105
104
108
107
103
106
109
111
110
102
GLASS SHOWER
& DOOR
GLASS SHOWER
& DOOR
2' - 9"
3' - 0" 2' - 6" 101
112
NEW TOILET LOCATION
NEW DRAIN LOCATION
NEW SINK LOCATION
CONTINUOUS 5/8"
TYPE "X" DRYWALL
CONTINUOUS 5/8"
TYPE "X" DRYWALL
NEW DRAIN
LOCATION
EXISTING TOILET
LOCATION
EXISTING SINK
LOCATION
LIVING ROOM
DINING /
KITCHEN
CABINET DESIGN BY
OTHERS
APPLIANCE/FIXTURE
SELECTIONS BY OTHERS
A1
1 ALL COMMON WALLS TYP.
SEE DETAIL SECTION
FRONT PORCH
NO CHANGE
1-HR RATED
PANEL DOOR
FOR ACCESS TO
LEGACY WATER
VALVE
12' - 2"
LOUVERED DOOR
1
0 1 5 10
SEE MECH.
NOTES
9 10
4' - 3 3/4" 5' - 4 1/4"
SEE DRYER
VENT NOTE
7
SEE MECH.
CEILING NOTE
8
A1
1 ALL COMMON WALLS TYP.
SEE DETAIL SECTION
WP RECESSED CAN LIGHT (wet location)
RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED CHANDELIER
RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
UNDERCABINET LIGHT
FLUORESCENT CLOSET LIGHT
(JS=JAMB SWITCH)
CEILING EXHAUST FAN
1/2 HOT DUPLEX OUTLET
ELECTRICAL SYMBOL LEGEND
DUPLEX OUTLET RECEPTACLE
S D
3S SSINGLE SWITCH
3-WAY SWITCH
DIMMER SWITCH
CEILING MOUNTED SCONCE OR PENDANT
F
WIRED SMOKE DETECTOR
RECESSED FLOOR DUPLEX OUTLET
S F FAN CONTROLS
S
GFCI DUPLEX OUTLET
PHONE/DATA OUTLET
TV CABLE/COAX OUTLET
TRACK LIGHTING
LIGHT BAR - VANITY
WIRED CARBON MONOXIDE DETECTOR
CM
NOTES:
1. 75% OF LIGHTING TO BE HIGH EFFICACY - 2014 NEC.
2. ONLY SELECT RECEPTACLES SHOWN. ELECTRICAL CONTRACTOR TO PROVIDE
ALL REQUIRED BY CODE.
R314.3 Location.
Smoke alarms shall be installed in the following locations:
1. In each sleeping room.
2. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
3. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level
is less than one full story below the upper level.
R314.4 Power source.
Smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial
source, and when primary power is interrupted, shall receive power from a battery. Wiring shall be permanent and
without a disconnecting switch other than those required for overcurrent protection.
R315.1 Carbon monoxide alarms.
For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in
the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling
units that have attached garages.
R315.4 Alarm requirements.
Single-station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance
with this code and the manufacturer’s installation instructions.
ELECTRICAL NOTES
3
S
3
S
3 S
3
S
3 S
3 S
S S
S
D
S F
S
D
S F SD
+42" +42"
+42"
+42"
WP
WP
F F
CEILING EXHAUST FAN:
"AIR KING" MODEL FRAK90
FIRE RATED 90 CFM
CEILING EXHAUST FAN
(OR EQUAL)
S
S
S
CM
D SPOWER FOR HOOD
FAN & LIGHT
GARBAGE DISPOSAL
S
S S
S D
S D
+42"
+42"
CEILING EXHAUST FAN:
"AIR KING" MODEL FRAK90
FIRE RATED 90 CFM
CEILING EXHAUST FAN
(OR EQUAL)
1
1
1
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project number
Date REVISIONS
6/23/2016
8:51:27 AM
121 W Meadow Dr #A103
Vail, Colorado A2
FLOOR
PLAN & RCP
xxxx FULLER
RENOVATION
PERMIT
SET
4-21-16
4-21-16
FULLER
No. Description Date
1 Revision 1 6-23-16
3/8" = 1'-0"
1
FLOOR PLAN
3/8" = 1'-0" 2
REFLECTED CEILING PLAN
INTERIOR DOOR SCHEDULE
Mark Family Width Height Comments
101 Single-6-panel 2' - 6" 6' - 8"
102 Single-6-panel 2' - 6" 6' - 8"
103 Single-6-panel 2' - 0" 6' - 8"
104 Single-6-panel 2' - 0" 6' - 8"
105 Single-6-panel 2' - 0" 6' - 8"
106 Single-6-panel_ 2' - 8" 6' - 8" louvered
door
107 Sliding-Closet-6 panel 4' - 0" 6' - 8"
108 Sliding-Closet-6 panel 4' - 0" 6' - 8"
109 Single-6-panel_ 2' - 0" 6' - 8"
110 Single-6-panel_ 2' - 0" 6' - 8"
111 Sliding-Closet-6 panel 4' - 0" 6' - 8"
112 Sliding-Closet-6 panel 4' - 0" 6' - 8"
DOOR NOTES:
1. ALL DOOR SELECTIONS BY OWNER / CONTRACTOR.
2. ALL HARDWARE AND LOCK SELECTIONS BY OWNER / CONTRACTOR.
EXISTING COLUMN
1
1
07/26/16