Loading...
HomeMy WebLinkAboutB16-0192_A2_1478902047.pdfUP DN UP DN EXISTING BEARING WALL EXISTING POSTS AT STAIR EXISTING POST IN WALL EXISTING CONC. FOUNDATION WALL NEW "POINT LOAD" POST, ON TOP OF EXISTING FOUNDATION WALL 3 A5 1 A5 2 A5 4 A5 2' - 6" 19' - 0" 2' - 6" EXTEND STOOP NEW ANGLED POST NEW ENCLOSURE FOR ELEC METER WOOD SIDING TO REMAIN PAINT HANDRAILS EXISTING STAIRS TO RECEIVE NEW TREAD MATERIAL AND RAILING DESIGN REMOVE POSTS AND CEILING STRUCTURE NEW "POINT LOAD" POST CUT INTO STUD WALL ON TOP OF EXISTING FOUNDATION WALL NEW "POINT LOAD" POST, CUT INTO STUD WALL ON TOP OF EXISTING FOUNDATION WALL FASCIA AND SHORT ROOF OVERHANG TO BE SALVAGED FASCIA AND SHORT ROOF OVERHANG TO BE SALVAGED SNOW MELT BOILER TO REMAIN DURING CONSTRUCTION. CONTRACTOR TO BUILD A TEMPORARY PROTECTIVE ENCLOSURE. GARAGE DOORS TO BE REPLACE WITHIN EXISTING OPENING EXISTING WINDOWS TO REMAIN NEW STEEL BEAM ABOVE RE: STRUCT. DWGS. LIVING ROOM DINING ROOM STORAGE GUEST BEDROOM KITCHEN MUD ROOM ENTRY GUEST BATH POWDE R EXISTING GARAGE CONC. SLAB TO REMAIN DECK PAINT HANDRAILS WOOD SIDING TO REMAIN STONE TO REMAIN 0' 2' 4' 8' 16' PROJECT NORTH LIGHTING AND ALARM NOTES: 1. 50% OF LIGHTING TO BE HIGH EFFICANCY. 2. ELECTRICAL SWITCHING PLAN AND LOAD CALCS BY OTHERS. 3. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS PER IBC 2015: R314.3 Location. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. R314.4 Power source. Smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source, and when primary power is interrupted, shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. R315.1 Carbon monoxide alarms. For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages. R315.4 Alarm requirements. Single-station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this code and the manufacturer’s installation instructions. S CM SMOKE DETECTORS (WIRED) CARBON MONOXIDE DETECTORS (WIRED) CM S S 1172.8 SF BASEMENT 577.5 SF GARAGE 1184.3 SF MAIN LEVEL 450 SF UPPER LEVEL EXIST 409.3 SF UPPER LEVEL NEW GRFA CALCULATIONS: BASEMENT PERCENTAGE CALCULATIONS: TOTAL WALL SURFACE = 1,230 SQ. FT. TOTAL UNEXPOSED SURFACE = 614 SQ. FT. THE BASEMENT IS 50% UNEXPOSED BASEMENT LEVEL GROSS = 1,172 S.F. BASEMENT DEDUCTION (50%) = -586 S.F. BASMENT GRFA = 586 S.F. MAIN LEVEL GROSS = 1,761 S.F. GARAGE DEDUCTION = (-577 S.F.) MAIN LEVEL GRFA = 1,184 S.F. UPPER LEVEL GRFA = 859 S.F. TOTAL GRFA = 2,629 S.F. 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 5/24/2016 2:17:43 PM 2528 Arosa Drive, Vail, CO Vail Das Schone Filing 1, Block C, Lot 7 A2 MAIN, BASEMENT & AREA PLANS xxxx Harris Renovation PERMIT SET 4-20-16 4-20-16 Harris Family 1/8" = 1'-0" 2 1. FLOOR PLAN - BASEMENT LEVEL 1/4" = 1'-0" 3 2. FLOOR PLAN - MAIN LEVEL 1" = 10'-0" 1 Basement 1" = 10'-0" 4 Main Level 1" = 10'-0" 5 Upper Level Area Schedule (Gross Building) Name Area BASEMENT 1172.8 SF GARAGE 577.5 SF MAIN LEVEL 1184.3 SF UPPER LEVEL EXIST 450 SF UPPER LEVEL NEW 409.3 SF Grand total: 5 3793.8 SF Area Schedule (Living Area) Name Area BASEMENT 1172.8 SF MAIN LEVEL 1184.3 SF UPPER LEVEL EXIST 450 SF UPPER LEVEL NEW 409.3 SF Grand total: 4 3216.3 SF 1 1/2" = 1'-0" 6 GRFA SUMMARY No. Description Date 06/13/16