HomeMy WebLinkAboutB16-0192_A2_1478902047.pdfUP
DN
UP
DN
EXISTING BEARING WALL
EXISTING POSTS AT STAIR
EXISTING
POST IN WALL
EXISTING CONC.
FOUNDATION WALL
NEW "POINT LOAD" POST, ON TOP
OF EXISTING FOUNDATION WALL
3
A5
1
A5
2
A5
4
A5
2' - 6" 19' - 0" 2' - 6"
EXTEND STOOP
NEW ANGLED
POST
NEW ENCLOSURE
FOR ELEC METER
WOOD SIDING TO
REMAIN
PAINT HANDRAILS
EXISTING STAIRS TO RECEIVE
NEW TREAD MATERIAL AND
RAILING DESIGN
REMOVE POSTS AND
CEILING STRUCTURE
NEW "POINT LOAD" POST CUT INTO STUD WALL
ON TOP OF EXISTING FOUNDATION WALL
NEW "POINT LOAD" POST, CUT INTO STUD WALL
ON TOP OF EXISTING FOUNDATION WALL
FASCIA AND SHORT
ROOF OVERHANG TO
BE SALVAGED
FASCIA AND SHORT
ROOF OVERHANG TO
BE SALVAGED
SNOW MELT BOILER TO REMAIN
DURING CONSTRUCTION.
CONTRACTOR TO BUILD A
TEMPORARY PROTECTIVE
ENCLOSURE.
GARAGE DOORS TO BE
REPLACE WITHIN
EXISTING OPENING
EXISTING WINDOWS TO REMAIN
NEW STEEL BEAM ABOVE
RE: STRUCT. DWGS.
LIVING ROOM DINING ROOM
STORAGE
GUEST BEDROOM
KITCHEN
MUD
ROOM
ENTRY
GUEST BATH
POWDE
R
EXISTING GARAGE
CONC. SLAB TO REMAIN
DECK
PAINT HANDRAILS
WOOD SIDING TO REMAIN
STONE TO REMAIN
0' 2' 4' 8' 16'
PROJECT
NORTH
LIGHTING AND ALARM NOTES:
1. 50% OF LIGHTING TO BE HIGH EFFICANCY.
2. ELECTRICAL SWITCHING PLAN AND LOAD CALCS BY OTHERS.
3. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS PER IBC 2015:
R314.3 Location.
Smoke alarms shall be installed in the following locations:
1. In each sleeping room.
2. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
3. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling
units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level
provided that the lower level is less than one full story below the upper level.
R314.4 Power source.
Smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source, and when primary power is interrupted,
shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection.
R315.1 Carbon monoxide alarms.
For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms
in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.
R315.4 Alarm requirements.
Single-station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this code and the manufacturer’s installation
instructions.
S
CM
SMOKE DETECTORS
(WIRED)
CARBON MONOXIDE DETECTORS
(WIRED)
CM
S
S
1172.8
SF
BASEMENT
577.5 SF
GARAGE
1184.3
SF
MAIN LEVEL
450 SF
UPPER LEVEL EXIST
409.3 SF
UPPER LEVEL NEW
GRFA CALCULATIONS:
BASEMENT PERCENTAGE CALCULATIONS:
TOTAL WALL SURFACE = 1,230 SQ. FT.
TOTAL UNEXPOSED SURFACE = 614 SQ. FT.
THE BASEMENT IS 50% UNEXPOSED
BASEMENT LEVEL GROSS = 1,172 S.F.
BASEMENT DEDUCTION (50%) = -586 S.F.
BASMENT GRFA = 586 S.F.
MAIN LEVEL GROSS = 1,761 S.F.
GARAGE DEDUCTION = (-577 S.F.)
MAIN LEVEL GRFA = 1,184 S.F.
UPPER LEVEL GRFA = 859 S.F.
TOTAL GRFA = 2,629 S.F.
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project number
Date REVISIONS
5/24/2016
2:17:43 PM
2528
Arosa
Drive,
Vail, CO
Vail Das Schone
Filing 1, Block C, Lot 7 A2
MAIN,
BASEMENT & AREA
PLANS
xxxx
Harris
Renovation
PERMIT
SET
4-20-16
4-20-16
Harris
Family
1/8" = 1'-0" 2
1. FLOOR PLAN - BASEMENT LEVEL
1/4" = 1'-0"
3
2. FLOOR PLAN - MAIN LEVEL
1" = 10'-0"
1
Basement
1" = 10'-0" 4
Main Level
1" = 10'-0" 5
Upper Level
Area Schedule (Gross Building)
Name Area
BASEMENT 1172.8 SF
GARAGE 577.5 SF
MAIN LEVEL 1184.3 SF
UPPER LEVEL EXIST 450 SF
UPPER LEVEL NEW 409.3 SF
Grand total: 5 3793.8 SF
Area Schedule (Living Area)
Name Area
BASEMENT 1172.8 SF
MAIN LEVEL 1184.3 SF
UPPER LEVEL EXIST 450 SF
UPPER LEVEL NEW 409.3 SF
Grand total: 4 3216.3 SF 1 1/2" = 1'-0"
6
GRFA SUMMARY
No. Description Date
06/13/16