Loading...
HomeMy WebLinkAboutB16-0192_A6_1492207860.pdfW.P.MEMBRANE OVER SLOPING RIGID INSULATION R-35 BLOWN-IN INSULATION TO FILL 9 1/4" STUD SPACE T.O.PLYWOOD 8'-6" TO SLAB BELOW 9'-0" TO SLAB BELOW 5/8" DRYWALL FINISH FLOOR 11 7/8" JOISTS SHEATHING 2X14 BELLY BAND METAL FLASHING W/ DRIP EDGE DECKING PALETTES: 2X6 REDWOOD DECKING NAILED TO 2X4 SLEEPERS W/ RIPPED (SLOPING) BOTTOMS. PALETTES SIT ON MEMBRANE W/ NO PENETRATIONS AND CAN BE REMOVED FOR MAINTENANCE. 6X6 POST BEYOND SEE RAILING DETAIL 8 1/8"9 1/4"6"1' - 2"1X4 T&G CEDAR SOFFIT STEEL BEAM SURROUND W/ SPRAY FOAM INSULATION 2' - 1 3/4" 11 1/4"1' - 2"2X12 OUTRIGGERS BLOCKING R-56 BIBS INSULATION COMPLETELY FILL 14" SPACE NO VENTING METAL ROOF METAL FLASHING 12" FASCIA BOARD (TO MATCH EXISTING) 1X4 T&G CEDAR SOFFIT METAL PANEL SIDING OVER W.P. MEMBRANE R-22 BLOWN-IN INSULATION 5/8" DRYWALL 5/8" DRYWALL 12 2 Town of Vail amendment to the code: Table C402.1.3 - Opaque Thermal Envelope Insulation Components Minimum Requirements, R- Value Method: Table C402.1.3 is amended by the addition of the following: "Wood framed and other may use R-21 in lieu of continuous insulation." Section R402.2.11 - Heated Slab- On- Grade Floors: Section R402.2.11 is added, to read as follows: "A minimum of R-10 insulation shall be installed under the slab extending horizontally from the exterior wall of the building envelope for 4 feet." 1 1/2"3 1/2" 2' - 2 1/2" 3 1/2" 2 1/2" 3' - 1 1/2"3 1/2" 1 1/2" 5 1/2" 1 1/2" 2X2 PICKETS 2X4 TOP AND BOTTOM RAILS 2X6 TOP RAIL (SLOPE TOP) 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS3/23/2017 5:05:08 PMA6 DETAILS xxxxHarris RenovationPERMIT SET 4-20-16 11-16-16 Harris Family 2528 Arosa Drive, Vail, CO Vail Das Schone Filing 1, Block C, Lot 7 1" = 1'-0" 1 DECK DETAIL 1" = 1'-0" 2 ROOF SECTION INSULATION SUMMARY ALL MINIMUM INSULATION VALUES FROM IRC 2015 TABLE N1102.1.2 (R402.1.2) AND AMENDED CODES ROOF JOIST CAVITY = R-56 NON-VENTED (MIN. R-49) EXTERIOR WALL INSULATION = R-22 (MIN. R-21) BASEMENT WALL INSULATION = NA (MIN. R-19) SLAB PERIMETER INSULATION = NA (MIN. R-10) UNDER-SLAB INSULATION = NA (MIN. R-10) GARAGE CEILING AND FLOOR SOFFITS= R-35 (MIN. R-30) WINDOWS U-VALUE MAX. = U-.30 (MAX. U-.32) INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST SPACES AND HAVE PROPER AIR-BARRIER SHEATHING ON BOTH SIDES OF THE STUD/JOIST SPACES. GENERAL: FOAM ALL WINDOWS, DOORS, PENETRATIONS, ELECTRICAL BOXES, HEADERS. R-11 UNFACED FIBERGLASS BATTS AT 2X4 INTERIOR WALLS (SOUND) R-19 UNFACED FIBERGLASS BATTS AT 2X6 INTERIOR WALLS (SOUND) IRC 2015 AND IECC 2015 ENERGY EFFICIENCY 1" = 1'-0" 4 RAILING DETAIL No. Description DateDRB APPROVED 3/31/2017 12:00:00 AM 04/14/17