Loading...
HomeMy WebLinkAboutB16-0200_A20_1478897916.pdf6 7 8 9 10 11 DECK ABOVE SOFFIT ABOVE FF. = 8078.3' 15' - 10 13/16" 6' - 3 5/8" UNIT 6 672 SF 22' - 2 3/8" 31' - 10 13/16" 4' - 0" 6 7 8 9 10 11 LIVING ROOM ADDITION; SOFFIT ABOVE FF. = 8078.3' UNIT 6 672 SF 22' - 2 3/8" 31' - 10 13/16" ENTRY ADDITION NEW INSULATED GARAGE DOOR (TO MATCH DOOR AT UNIT 3) NEW WINDOWS AT FRONT & BACK SOFFIT ABOVE W/ NEW T&G FINISH & DOWNLIGHT 6 7 8 9 10 11 UNIT 6 EXTERIOR DECK HARDWOOD DECK 8087.5' FF. = 8087.5' FIREPLACE 6 7 8 9 10 11 UNIT 6 HARDWOOD DECK 8087.5' FF. = 8087.5' FIREPLACE AT MAIN LEVEL; MUD ROOM ADDITION AT LOWER LEVEL BELOW NEW WINDOWS AT FRONT & BACK PROPOSED LIVING ROOM ADDITION typ. 13 A501 typ. 1 A501 typ. 6 A500 8 A500 typ. typ. 6 A500 7' - 2 3/8" 15' - 4 11/16" 6 7 8 9 10 11 FIREPLACE FF. = 8098.2' UNIT 6 6 7 8 9 10 11 FIREPLACE FF. = 8098.2' UNIT 6 NEW WINDOWS AT FRONT & BACK typ. 12 A500 typ. 12 A500 12 A500 typ. typ. 12 A500 Drive & Parking Lot 70' - 0" Lower Level - Existing Plan 74' - 1 1/4" Main Level - Existing Plan 83' - 6" Upper Level - Existing Plan 94' - 1 1/4" Roof Level TH.1 104' - 10 3/4" 6 7 UNIT 6 Vertical Wood Siding to be replaced with alternate material Horizontal Wood Siding to be replaced with CVG 1x 6 Cedar T&G Siding Stucco to be refinished with new Drive & Parking Lot 70' - 0" Lower Level - Existing Plan 74' - 1 1/4" Main Level - Existing Plan 83' - 6" Upper Level - Existing Plan 94' - 1 1/4" Roof Level TH.1 104' - 10 3/4" 6 7 UNIT 6 NOTES: - Entry Mud Room Addition at Units 2 & 6 - Living Room Addition at Units 2 & 6 - Deck Extension at Units 1, 3, & 5 - Bedroom Additions at Units 2 & 4 - Stucco finish on all wing walls - Plywood Sheathing & VaproShield "WrapShield R.S." Rainscreen replacement; vfy damaged locations @ exterior - Entry Mud Room Addition - Living Room Addition - Standing Seam Roof ≥ 3:12 - Stone Veneer - New Pella Entry Door & Sidelight - New Windows & Doors - New Insulated Garage Door - Heattape all gutter and downspouts, typ. Fireplace Renovations - Stone Veneer Wall Surrounds - Metal Clad Fireplace Cap Roof Cap, Paint to match siding CVG 1x 6 Cedar T&G Siding Living Room Addition - Standing Seam Roof ≥ 3:12 - Stucco Wall Finish w/ 3/8" Reglet Stone Veneer Base on Stucco wing walls; vfy fastening system 48"AFF New Unit Number, Finish TBD, 6' typ. height Roof Additions at Units 2 & 6 - Standing Seam Metal Roof 16" - Facia to match Wood Siding - Snow Retention (clip by roofer) New T&G finish at Soffit w/ new downlight, typ. Reglet at Stucco Wood trim at windows on siding, Stain to match Stucco trim at windows on stucco Wood trim at windows on siding, Stain to match 5 A500typ. typ. 6 A500 typ. 10 A501 typ. 3 A501 4 A501 typ. 2 A501 typ. All exist. recessed cans at Entry soffits to be upgraded to Dark Sky Complaint fixtures 1 A501 typ. Stucco finish w/ 3/8" Reglet Project number Date Drawn by 5/27/2016 6:37:24 PM A2.0 Existing and Proposed Floor Plans and Elevations ----Capstone Townhomes 1817 Meadow Ridge Rd. Vail, CO 81657 UNIT #6 ENTRY AND LIVING ROOM ADDITION 05-24-2016 Author No. Description Date 1/8" = 1'-0" 1 Unit #6 Lower Level - Existing Plan 1/8" = 1'-0" 2 Unit #6 Lower Level - Proposed Plan 1/8" = 1'-0" 3 Unit #6 Main Level - Existing Plan 1/8" = 1'-0" 4 Unit #6 Main Level - Proposed Plan 1/8" = 1'-0" 5 Unit #6 Upper Level - Existing Plan 1/8" = 1'-0" 6 Unit #6 Upper Level - Proposed Plan 1/8" = 1'-0" 7 Unit #6 East Elevation - Existing 1/8" = 1'-0" 8 Unit #6 East Elevation - Proposed 08/23/16