HomeMy WebLinkAboutB16-0200_A20_1478897916.pdf6
7
8 9 10 11
DECK
ABOVE
SOFFIT
ABOVE
FF. = 8078.3'
15' - 10 13/16"
6' - 3 5/8" UNIT 6
672 SF
22' - 2 3/8"
31' - 10 13/16"
4' - 0"
6
7
8 9 10 11
LIVING ROOM ADDITION;
SOFFIT ABOVE
FF. = 8078.3'
UNIT 6
672 SF
22' - 2 3/8" 31' - 10 13/16"
ENTRY ADDITION
NEW INSULATED GARAGE DOOR
(TO MATCH DOOR AT UNIT 3)
NEW WINDOWS AT FRONT &
BACK
SOFFIT ABOVE W/
NEW T&G FINISH &
DOWNLIGHT
6
7
8 9 10 11
UNIT 6
EXTERIOR
DECK
HARDWOOD
DECK
8087.5'
FF. = 8087.5'
FIREPLACE
6
7
8 9 10 11
UNIT 6
HARDWOOD
DECK
8087.5'
FF. = 8087.5'
FIREPLACE AT MAIN LEVEL;
MUD ROOM ADDITION AT
LOWER LEVEL BELOW
NEW WINDOWS AT
FRONT & BACK
PROPOSED LIVING
ROOM ADDITION
typ.
13
A501
typ.
1
A501
typ.
6
A500
8
A500
typ.
typ.
6
A500
7' - 2 3/8"
15' - 4 11/16"
6
7
8 9 10 11
FIREPLACE
FF. = 8098.2'
UNIT 6
6
7
8 9 10 11
FIREPLACE
FF. = 8098.2'
UNIT 6
NEW WINDOWS
AT FRONT &
BACK
typ.
12
A500
typ.
12
A500
12
A500
typ.
typ.
12
A500
Drive & Parking Lot
70' - 0"
Lower Level -
Existing Plan
74' - 1 1/4"
Main Level - Existing
Plan
83' - 6"
Upper Level -
Existing Plan
94' - 1 1/4"
Roof Level TH.1
104' - 10 3/4"
6
7
UNIT 6
Vertical Wood Siding to be
replaced with alternate material
Horizontal Wood Siding to be
replaced with CVG 1x 6 Cedar
T&G Siding
Stucco to be refinished with new
Drive & Parking Lot
70' - 0"
Lower Level -
Existing Plan
74' - 1 1/4"
Main Level - Existing
Plan
83' - 6"
Upper Level -
Existing Plan
94' - 1 1/4"
Roof Level TH.1
104' - 10 3/4"
6
7
UNIT 6
NOTES:
- Entry Mud Room Addition at Units 2 & 6
- Living Room Addition at Units 2 & 6
- Deck Extension at Units 1, 3, & 5
- Bedroom Additions at Units 2 & 4
- Stucco finish on all wing walls
- Plywood Sheathing & VaproShield "WrapShield
R.S." Rainscreen replacement; vfy damaged
locations @ exterior
- Entry Mud Room Addition
- Living Room Addition
- Standing Seam Roof ≥ 3:12
- Stone Veneer
- New Pella Entry Door & Sidelight
- New Windows & Doors
- New Insulated Garage Door
- Heattape all gutter and downspouts, typ.
Fireplace Renovations
- Stone Veneer Wall Surrounds
- Metal Clad Fireplace Cap
Roof Cap, Paint to match siding
CVG 1x 6 Cedar T&G Siding
Living Room Addition
- Standing Seam Roof ≥ 3:12
- Stucco Wall Finish w/ 3/8" Reglet
Stone Veneer Base on Stucco wing walls;
vfy fastening system 48"AFF
New Unit Number, Finish TBD, 6' typ. height
Roof Additions at Units 2 & 6
- Standing Seam Metal Roof 16"
- Facia to match Wood Siding
- Snow Retention (clip by roofer)
New T&G finish at Soffit w/ new downlight, typ.
Reglet at Stucco
Wood trim at windows on siding,
Stain to match
Stucco trim at windows on stucco
Wood trim at windows on siding,
Stain to match
5
A500typ.
typ.
6
A500
typ.
10
A501
typ.
3
A501
4
A501
typ.
2
A501
typ.
All exist. recessed cans at Entry soffits to be
upgraded to Dark Sky Complaint fixtures
1
A501
typ.
Stucco finish w/ 3/8" Reglet
Project number
Date
Drawn by
5/27/2016
6:37:24 PM
A2.0
Existing and Proposed Floor Plans
and Elevations
----Capstone
Townhomes
1817
Meadow
Ridge Rd.
Vail, CO 81657
UNIT #6 ENTRY
AND
LIVING
ROOM
ADDITION
05-24-2016
Author
No. Description Date
1/8" = 1'-0" 1
Unit #6 Lower Level - Existing Plan
1/8" = 1'-0" 2
Unit #6 Lower Level - Proposed Plan
1/8" = 1'-0" 3
Unit #6 Main Level - Existing Plan
1/8" = 1'-0" 4
Unit #6 Main Level - Proposed Plan
1/8" = 1'-0"
5
Unit #6 Upper Level - Existing Plan
1/8" = 1'-0"
6
Unit #6 Upper Level - Proposed Plan
1/8" = 1'-0" 7
Unit #6 East Elevation - Existing
1/8" = 1'-0" 8
Unit #6 East Elevation - Proposed
08/23/16