HomeMy WebLinkAboutB16-0204_5MP2.0_1478906847.pdfLV 1 FD 4 FD 4 WC 2 UR 3 MS 5 3" V.U.T.R EF 1 L 1 LV 1 WC 2 HB 6 UR 3 CONNECT 1 2" CW, 1 1 2" W & 1 1 2" V TO LV. CONNECT 1" CW, 3" W & 2" V TO WC. CONNECT 1" CW, 2" W & 1 1 2" V TO UR. CONNECT 2" W & 1 1 2" V TO MS. CONNECT 2" W & 1 1 2" V TO FD. CONNECT 3 4" CW TO HB. 2" V TO HANDLE ALL FIXTURES CONVERGING IN THIS LOCATION. SHEET DETAIL NOTES: 1 2 3 4 5 6 WATER ENTRY (SEE DETAIL) D STRAINER RPBFP-1 WATER SERVICE BY THE CIVIL CONTRACTOR. RE: CIVIL PLAN FOR CONTINUATION, EXACT SIZE, LOCATION & INVERT ELEVATIONS. ANCHOR PIPING TO WALL TO WALL ANCHOR PIPING PRV: PRESSURE REDUCING VALVE REFERENCE THE ELECTRICAL DOCUMENTS FOR GROUNDING DETAILS ANCHOR PIPING TO WALL MAIN DOMESTIC WATER ENTRY DETAIL NO SCALE 1 1 4" 1" MINIMUM OF FIVE DIAMETERS OF STRAIGHT PIPE M MAIN SHUT OFF VALVE LOCATE WITHIN 5' OF THE ENTRY INTO THE BUILDING LINK SEAL PROVIDE APPROVED VERTICAL JOINT RESTRAINTS AS REQUIRED D RPBFP-2 ANCHOR PIPING TO WALL ROUTE DN TO FD OR PROVIDE TRAPPED FUNNEL INTO WASTE PIPE. ROUTE DN TO FD OR PROVIDE TRAPPED FUNNEL INTO WASTE PIPE. 1 1 4" TO PLUMBING FIXTURES TO IRRIGATION (MAX FLOW NOT TO EXCEED 12 GPM) VERIFY SIZE WITH LANDSCAPE ARCHITECT. PROVIDE AIR HOSE CONNECTION FOR WINTERIZATION. PROVIDE AIR HOSE CONNECTION FOR WINTERIZATION. SEE CIVIL PLANS FOR CONTINUATION INCLUDING AUXILIARY CURB STOP & WINTERIZATION DRAIN DOWN DETAIL. GENERAL NOTES: 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING AND/OR DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT AND/OR FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 3. INSTALL CLEANOUTS PER SECTION 708 OF THE IPC. NOT ALL REQUIRED CLEANOUTS NECESSARILY SHOWN. COORDINATE ALL FINAL LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION. R=W W RADIUS ELBOW DETAIL NO SCALE R=W W RADIUS ELBOW DETAIL NO SCALE 29" MAX 32"-34" 27" MIN 8" MIN 8" MIN DOES NOT INCLUDE OVERFLOW 9" MIN 17" MIN. PROVIDE 'TRUEBRO' #103 INSULATION KIT ADA PEDESTAL LAVATORY NO SCALE 5 1/2" INSIDE WALL OUTSIDE WALL 1" PIPE INSULATION LOCATE PIPE TO INSIDE WALL VERIFY THAT ALL INSULATION AROUND PIPING IS EQUALLY DISTRIBUTED WITHOUT ANY AIR GAPS OR UN-INSULATED AREAS. INSULATION PIPE IN OUTSIDE WALL DETAIL NO SCALE: WALL CLEANOUT DIAGRAM NO SCALE BALANCE OF PIPING SAME AS CLEANOUT TO GRADE 1 8 " C.I. BEND FLOOR LINE PLUGGED TEE WITH CLEAN OUT EXTERIOR WALL CHROME WALLCOVER AND SCREW 1'-0" 2-WAY C.O.T.G. DETAIL NO SCALE FINISHED GRADE OR FLOOR COTG TOP COVER CITY SEWER LINE GRAVEL C.I. 6" 2-WAY COTG WASTE LINE CLEANOUT SCHEMATICS NO SCALE CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/TOP OF FLOOR FLOOR LINE BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 C.I. BEND FLOOR CLEANOUT (FCO) CLEANOUT NOT TO BE LOCATED IN CARPETED AREA. CLEANOUT TO GRADE (COTG) 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. C.I. WASTE LINE. LGTH TO SUIT. 1/8 C.I. BEND FINISHED GRADE BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD 16"Ø CONC. PAD TROWEL SMOOTH & EDGE UPSIZE TO 4" W PRIOR TO EXITING BUILDING. SEE CIVIL PLANS FOR CONTINUATION. 1" CW BELOW SLAB 1 1 4" CW 1 1 4" CW 3 4" CW 3" W 2" W 1" METER 7 7 7 PROVIDE HAMMER ARRESTOR TO PROTECT PIPING DURING WINTERIZATION of Drawn By: Checked By: DATE: ISSUE: 04-15-16 PROGRESS AEC PROJECT #: VAIL PICKLEBALL COURT BATHROOM VAIL,CO 16022 www.aec-vail.com a 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620 Mechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 c eAn Office with LEED™ Accredited Professionals 04-18-16 PERMIT -$9 61% /'%*#0+%#.  2.7/$+0) 2.#05 &6.5  5%*'&7.'5 5%#.'   žÄ /2   NORTH WASTE & VENT PLAN SCALE: 1/4" = 1'0" NORTH DOMESTIC WATER PLAN SCALE: 1/4" = 1'0" NORTH MECHANICAL PLAN SCALE: 1/4" = 1'0" Paint exterior vent pipes to match exterior background color. 06/23/16