HomeMy WebLinkAboutB16-0212_A000_1478905109.pdfFOR CONSTRUCTION
Project number
Date
Drawn by
6/7/2016
10:42:47 AM
A000
COVER SHEET
ROA-16
1450
LIONSRIDGE
LOOP
VAIL,
COLORADO
ROACH
RESIDENCE
05/27/16
WMC
PERMIT 05.27.2016
ROACH RESIDENCE
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING
ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE
PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD
COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND
ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL
PLATES OR BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS
INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS,
TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE
BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR
DOOR TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR
WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING
FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE
CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL
IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT
SHALL NOT CONSTITUTE A DELAY IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL
APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS
PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE
INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION
DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT
CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING,
OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT
THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING
ANY SITE WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF &
DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE
MINIMAL PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S
WRITTEN APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL
CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS
TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE
RECOGNIZED STANDARDS OF THE INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE
SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION
IMPACTS TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE
ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF
EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH
THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL
BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS
FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT.
1450 LIONSRIDGE LOOP
DRAWING INDEX
ARCHITECTURAL:
A001 GRFA PLANS
A101 EXISTING FLOOR PLANS
A102 EXISTING FLOOR PLANS
A103 DEMO PLANS
A104 DEMO PLANS
A105 PROPOSED FLOOR PLANS
A106 PROPOSED FLOOR PLANS
A111 PROPOSED RCPs
A112 PROPOSED RCPs
A201 EXISTING ELEVATIONS
A202 PROPOSED ELEVATIONS
A901 3D DRAWINGS/RENDERINGS
STRUCTURAL:
S1 STRUCTURAL PLANS
S2 STRUCTURAL DETAILS
PROJECT SUMMARY:
CODE:
IRC 2015
ZONING:
SPECIAL DEVELOPMENT DISTRICT #22
UNDERLYING TWO-FAMILY PRIMARY/SECONDARY
OCCUPANCY CLASSIFICATION:
TYPE R DIV. 3
PROJECT TEAM:
ARCHITECT:
CURRENT ARCHITECTS
PO BOX 5293
VAIL, CO 81657
PH: 970.331.6345
CONTACTS:
MICHAEL CURRENT
PROXIMITY MAP:
1450 LIONSRIDGE LOOP
VAIL, COLORADO 81657
No. Description Date
06/22/16