Loading...
HomeMy WebLinkAboutB16-0258_E-GR-414_1478899861.pdfSP LT-01 N4L N2 DB N4 N1 J LT-02 LT-02 SP DB GFCI LT-01 N4L N2 DB N1 LT-02 LT-02 J DB LT-03 SP N2 N4 GFCI GFCI SP SP SP DB DB SP SP N4L LT-01 N2 N1 LT-02 LT-02 J LT-03 N4 ST ST GFCI ACTIVITY Draw Design Manager BY Check DATE KEY PLAN REVISIONS DESCRIPTION NO. FILE LOG STAMP RYAN TAYLOR XX TRAVIS LEAST XX 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 Project No. © LEO A DALY Company 2016 OWNER: LAURUS CORPORATION 1880 CENTURY PARK EAST, SUITE 1016 LOS ANGELES, CA 90067 DEVELOPER: DESTINATION HOTELS &RESORTS 10333 EAST DRY CREEK ROAD, SUITE 450 ENGLEWOOD, CO 80112 VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 EST. 1915 P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S ENLARGED ELECTRICAL GUESTROOM PLANS 3CK, 3DK AND 3EKADA E-GR-414 1. PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, SUPERVISION, COSTS, AND SERVICES REQUIRED TO INSTALL COMPLETE AND WORKING SYSTEMS INCLUDING ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLY INCIDENTAL, OR CUSTOMARILY INCLUDED, EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFICALLY SPECIFIED OR SHOWN. 2. PROVIDE AN EMPTY CONDUIT RACEWAY, INCLUDING BACKBOXES, FOR ALL TELEPHONE, DATA, TELEVISION, SECURITY, AND FIRE ALARM SYSTEM CABLING REQUIREMENTS. RACEWAYS SHALL BE INSTALLED FROM DEVICE TO NEAREST ACCESSIBLE CEILING SPACE OR ACCESS DOOR LOCATION. 3. PROVIDE AND SECURE ALL CABLING AND CONDUIT RACEWAYS PER NEC AND LOCAL CODE REQUIREMENTS. ALL FITTINGS, BOXES, SLEEVES, AND PENETRATIONS SHALL BE SEALED AND RATED ACCORDINGLY. 4. REFER TO VOLTAGE DROP CHART ON SHEET MR-E-001 FOR WIRING SIZES FOR LONG RUNS OF CIRCUIT. 5. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ELECTRICAL WIRING DEVICES. 6. PROVIDE AND INSTALL LIGHTING FIXTURES IN ACCORDANCE WITH THE ELECTRICAL LIGHTING PLAN AND AS SPECIFIED ON THE ELECTRICAL LIGHTING FIXTURE SCHEDULE; REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS AND DIMENSIONAL DATA. REFER TO ARCHITECTURAL PLANS FOR ALL "LT" FIXTURES FOR SPECIFICATION. 7. PROVIDE PUTTY PADS ON BACK AND SIDES OF EACH OUTLET BOX LOCATED ON A GUESTROOM DEMISING WALL AND THE CORRIDOR DEMISING WALL. 1. REMOVE EXISTING LIGHT FIXTURE; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 2. REMOVE EXISTING WALL SWITCH; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 3. REMOVE EXISTING RECEPTACLE; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 4. REMOVE EXISTING CEILING FAN; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 5. REMOVE EXISTING DATA/PHONE/TV OUTLET; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 6. REMOVE EXISTING SMOKE DETECTOR; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 7. REMOVE EXISTING POWER CONNECTION TO LIGHTED MIRROR; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 8. EXISTING HVAC UNIT TO REMAIN. 9. EXISTING FIRE ALARM SPEAKER TO BE RELOCATED. 10. REMOVE EXISTING ELECTRICAL BASE BOARD HEATER; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 1. PROVIDE NEW FIRE ALARM DEVICES AS SHOWN TO MATCH EXISTING BUILDING STANDARD. TIE IN NEW NOTIFICATION AND INITIATION CIRCUITS ON THE FLOOR. NEW SMOKE/HEAT DETECTOR TO BE SINGLE STATION TYPE WITH HEAT/SMOKE/CARBON MONOXIDE DETECTOR AND SOUNDER BASE. BASIS OF DESIGN: GENTEX 9120T. 2. CONNECT NEW BATHROOM RECEPTACLE TO EXISTING DEDICATED 120V BRANCH CIRCUIT RETAINED FROM DEMOLITION. 3. EXTEND EXISTING LOW-VOLTAGE CABLING FROM EXISTING DATA/PHONE/TV OUTLET (JUNCTION BOX) LOCATION TO NEW WIRING DEVICE. 4. PROVIDE DOOR JAMB SWITCH IN DOOR FRAME TO TURN LIGHTS ON WHEN DOOR IS OPEN. BASIS OF DESIGN: HUBBEL 2968. 5. NEW LIGHT TO BE MOUNTED UNDER VANITY. ALL PARTS OF LIGHT, CIRCUITING AND DRIVERS TO BE COMPLETELY CONCEALED. POWER TO BE BROUGHT IN FROM WALL UNDER VANITY SUCH THAT IT IS AT THE EDGE OF THE INSIDE OF VANITY AND CONCEALED COMPLETELY THROUGHOUT. 6. EXTEND EXISTING BRANCH CIRCUIT WIRING FROM EXISTING WIRING DEVICE (JUNCTION BOX) LOCATION TO NEW WIRING DEVICE(S). 7. PROVIDE NEW WIRED DOORBELL SYSTEM WITH PRIVACY AND HOUSEKEEPING COMMUNICATIONS. INSTALL DOORBELL BUTTON OUTSIDE OF ENTRY DOOR, CHIME AND PRIVACY / HOUSEKEEPING BUTTONS ON INSIDE OF ENTRY DOOR. MOUNT THE SYSTEM 120VAC TO 12VDC TRANSFORMER WITHIN JUNCTION BOX LOCATED IN CLOSET, INTERCONNECT SYSTEM COMPONENTS WITH HARNESS CABLING PER MANUFACTURER SPECIFICATIONS. BASIS OF DESIGN INNCOM #P563 (DOORBELL BUTTON), #P564 (PRIVACY / HOUSEKEEPING BUTTON), #PS564 (120VAC TO 12VDC TRANSFORMER). 8. EXISTING FIRE ALARM SPEAKER RELOCATED. PROVIDE NEW WIRING TO SPEAKER FROM CORRIDOR CIRCUIT. 9. PROVIDE LIGHTED SWITCH. BASIS OF DESIGN: LEVITON 5639-2X. UTILIZE EXISTING BRANCH CIRCUIT RETAINED FROM DEMOLITION AND CONNECT TO NEW LIGHTING FIXTURES. 10. PROVIDE DIMMER SWITCH. BASIS OF DESIGN: LEVITON IPL6-010. UTILIZE EXISTING BRANCH CIRCUIT RETAINED FROM DEMOLITION AND CONNECT TO NEW LIGHTING FIXTURES. 11. REPLACE EXISTING DUPLEX RECEPTACLE WITH NEW QUAD; INSTALL NEW DOUBLE GANG BACKBOX, OR AS REQUIRED, TO SUPPORT NEW WIRING DEVICE. 12. REPLACE EXISTING RECEPTACLE WITH NEW RECEPTACLE PER THE ELECTRICAL SPECIFICATIONS. 1. REFER TO MR-E-004 FOR DEMOLITION NOTES. 1 5 10 10 2 8 7 11 3 3 9 6 4 6 6 6 7 1 5 10 2 8 7 11 3 3 9 4 6 6 6 7 3 10 4 1 5 2 8 11 3 3 9 6 7 10 4 10 8 6 06-24-2016 Project No. 012-10378-000 JUNE 24, 2016 08/15/16