HomeMy WebLinkAboutB16-0258_E-GR-420_1490730420.pdf1 1 1 2 2 2 2 4 6 7 8 10 N4L LT-01 LT-02 LT-02 SP N4 GFCI N2 N4 EF-1 N1 1 2 3 3 6 4 5 8 9 11 6 LT-03 6 3 1 GFCI H 2 1 EF-1 2 N4L LT-01 LT-02 LT-02 SP N4 GFCI N2 N4 EF-1 N1 1 2 3 3 6 4 5 8 9 10 11 3 6 LT-03 6 1 GFCI 1 H 2 1 EF-1 2 1 1 1 ENLARGED ELECTRICAL GUESTROOM PLANS 6K AND 6QQ E-GR-420 1. PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, SUPERVISION, COSTS, AND SERVICES REQUIRED TO INSTALL COMPLETE AND WORKING SYSTEMS INCLUDING ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLY INCIDENTAL, OR CUSTOMARILY INCLUDED, EVEN THOUGH EACH AND EVERY ITEM IS NOT SPECIFICALLY SPECIFIED OR SHOWN. 2. PROVIDE AN EMPTY CONDUIT RACEWAY, INCLUDING BACKBOXES, FOR ALL TELEPHONE, DATA, TELEVISION, SECURITY, AND FIRE ALARM SYSTEM CABLING REQUIREMENTS. RACEWAYS SHALL BE INSTALLED FROM DEVICE TO NEAREST ACCESSIBLE CEILING SPACE OR ACCESS DOOR LOCATION. 3. PROVIDE AND SECURE ALL CABLING AND CONDUIT RACEWAYS PER NEC AND LOCAL CODE REQUIREMENTS. ALL FITTINGS, BOXES, SLEEVES, AND PENETRATIONS SHALL BE SEALED AND RATED ACCORDINGLY. 4. REFER TO VOLTAGE DROP CHART ON SHEET MR-E-001 FOR WIRING SIZES FOR LONG RUNS OF CIRCUIT. 5. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ELECTRICAL WIRING DEVICES. 6. PROVIDE AND INSTALL LIGHTING FIXTURES IN ACCORDANCE WITH THE ELECTRICAL LIGHTING PLAN AND AS SPECIFIED ON THE ELECTRICAL LIGHTING FIXTURE SCHEDULE; REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS AND DIMENSIONAL DATA. REFER TO ARCHITECTURAL PLANS FOR ALL "LT" FIXTURES FOR SPECIFICATION. 7. PROVIDE PUTTY PADS ON BACK AND SIDES OF EACH OUTLET BOX LOCATED ON A GUESTROOM DEMISING WALL AND THE CORRIDOR DEMISING WALL. 1. REMOVE EXISTING LIGHT FIXTURE; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 2. REMOVE EXISTING WALL SWITCH; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 3. REMOVE EXISTING RECEPTACLE; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 4. REMOVE EXISTING CEILING FAN; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 5. REMOVE EXISTING DATA/PHONE/TV OUTLET; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 6. REMOVE EXISTING SMOKE DETECTOR; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 7. REMOVE EXISTING POWER CONNECTION TO LIGHTED MIRROR; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 8. EXISTING HVAC UNIT TO REMAIN. 9. EXISTING FIRE ALARM SPEAKER TO BE RELOCATED. 10. REMOVE EXISTING ELECTRICAL BASE BOARD HEATER; CAP EXISTING WIRE (PROVIDE SPLICE CONNECTION WHERE NECESSARY FOR CIRCUIT CONTINUITY) AND PROVIDE NEW COVERPLATE. FINISH TO MATCH THAT OF NEW WALL FINISHES. 1. REFER TO MR-E-004 FOR DEMOLITION NOTES. ACTIVITY Draw Design Manager BY Check DATE KEY PLAN REVISIONS DESCRIPTION NO. FILE LOG STAMP RYAN TAYLOR SAM NAHAS SAM NAHAS JEFFERY MUSSER 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 Project No. © LEO A DALY Company 2016 OWNER: LAURUS CORPORATION 1880 CENTURY PARK EAST, SUITE 1016 LOS ANGELES, CA 90067 DEVELOPER: DESTINATION HOTELS &RESORTS 10333 EAST DRY CREEK ROAD, SUITE 450 ENGLEWOOD, CO 80112 VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 EST. 1915 P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S 012-10378-000 AUGUST 30, 2016 08/30/2016 REVISION 1 1 1. PROVIDE NEW FIRE ALARM DEVICES AS SHOWN TO MATCH EXISTING BUILDING STANDARD. TIE IN NEW NOTIFICATION AND INITIATION CIRCUITS ON THE FLOOR. NEW SMOKE/HEAT DETECTOR TO BE SINGLE STATION TYPE WITH HEAT/SMOKE/CARBON MONOXIDE DETECTOR AND SOUNDER BASE. BASIS OF DESIGN: GENTEX 9120T.CARBON MONOXIDE DETECTORS ONLY REQUIRED IN ROOMS WITH OPEN FLAMES. 2. CONNECT CIRCUIT AS FOLLOWS: -LOWER AND ENTRY LEVELS MAIN HOTEL- USE EXISTING CIRCUIT IN ROOM. -2ND-4TH MAIN HOTEL- PROVIDE CIRCUITS AS SHOWN IN THE OVERALL PLANS. -TERRACE WING- USE EXISTING CIRCUIT IN ROOM. 3. EXTEND EXISTING LOW-VOLTAGE CABLING FROM EXISTING DATA/PHONE/TV OUTLET (JUNCTION BOX) LOCATION TO NEW WIRING DEVICE. 4. PROVIDE DOOR JAMB SWITCH IN BOTH DOOR FRAMES TO TURN LIGHTS ON WHEN DOOR IS OPEN. BASIS OF DESIGN: HUBBEL 2968. 5. NEW LIGHT TO BE MOUNTED UNDER VANITY. ALL PARTS OF LIGHT, CIRCUITING AND DRIVERS TO BE COMPLETELY CONCEALED. POWER TO BE BROUGHT IN FROM WALL UNDER VANITY SUCH THAT IT IS AT THE EDGE OF THE INSIDE OF VANITY AND CONCEALED COMPLETELY THROUGHOUT. 6. EXTEND EXISTING BRANCH CIRCUIT WIRING FROM EXISTING WIRING DEVICE (JUNCTION BOX) LOCATION TO NEW WIRING DEVICE(S). 7. NOT USED 8. EXISTING FIRE ALARM SPEAKER RELOCATED. PROVIDE NEW WIRING TO SPEAKER FROM CORRIDOR CIRCUIT. 9. PROVIDE LIGHTED SWITCH. BASIS OF DESIGN: LEVITON OSS10 OCCUPANCY SENSOR WITH LIGHT SWITCH. UTILIZE EXISTING BRANCH CIRCUIT RETAINED FROM DEMOLITION AND CONNECT TO NEW LIGHTING FIXTURES. 10. PROVIDE DIMMER SWITCH. BASIS OF DESIGN: LEVITON IPL6-010. UTILIZE EXISTING BRANCH CIRCUIT RETAINED FROM DEMOLITION AND CONNECT TO NEW LIGHTING FIXTURES. 11. REPLACE EXISTING DUPLEX RECEPTACLE WITH NEW QUAD; INSTALL NEW DOUBLE GANG BACKBOX, OR AS REQUIRED, TO SUPPORT NEW WIRING DEVICE. 12. REPLACE EXISTING RECEPTACLE WITH NEW RECEPTACLE PER THE ELECTRICAL SPECIFICATIONS. 13. NOT USED. 1 1 1 09/30/2016 ASI # 1 2 8/30/16 09/30/2016 03/28/17