Loading...
HomeMy WebLinkAboutE16-0138 load calcsViola Residence Load Calculation 795 Potato Patch Drive #B, Vail CO A-Phase Electric, LLC www.aphaseelectricllc.com General Lighting and Receptacle Demand Load: 1914 sq. ft. x 3VA = 5742 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load:10,242 3,000 VA @ 100% =3,000 VA @ 35% =2,534.7 887.145 Total general lighting and Receptacle demand load:3,887 Range demand load: 12,000VA 8,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1.2 kva 1 1,200 Garbage disposal .8 kva 1 800 Washer 1.2 kva 1 1,200 Microwave 1.2 kva 1 1,200 Steam shower 9.6 kva 0 0 Hot tub 12 kva 0 0 Total fixed appliance load: 4,400 Heating load: boiler 0.2 1 200 heat tape 4 kva 1 4,000 Total heating load: 4,200 25% of largest motor:1,200 Viola Residence Load Calculation 795 Potato Patch Drive #B, Vail CO A-Phase Electric, LLC www.aphaseelectricllc.com Totals: General lighting and receptacles: 3,887 Range: 8,000 Dryer: 5,000 Fixed appliance: 4,400 Heating: 4,200 25% of largest motor: 1,200 Total:VA 26,687 AMPS 111.20 Installed Service Size: 200A single phase Secondary Conductors: 4/0 AL XHHW