Loading...
HomeMy WebLinkAboutElectrical Load Calculation July 2016__44 Willows Place.pdfRESIDENTIAL LOAD CALCULATION - CENTRAL AIR CONDTIONING AND GAS HEATING NEC 220.82 Richard J. Moss, PE Rader Engineering, Inc. July, 2016 44 Willows Place Area 3,231 3va/sf 9693 Kitchen Appl Circuits 2 1500 3000 Electric Ovens 1 8900 8900 Microwave Ovens 1 1200 1200 Dishwashers 1 1500 1500 Large Refrigerators 1 1200 1200 Disposers 1 800 800 Clothes Washer 1 1200 1200 Clothes Dryer 1 5000 5000 Humidifiers 2 2400 0 Non Simultaneous Load w/ A/C Steam Generator 1 9000 9000 Elevator 0 0 0 Elevator Lts and Cntrols 0 0 0 Whirlpool Tubs 1 5000 5000 Snow Melting 1 21960 0 Non Simultaneous Load w/ A/C Outdoor Spa 1 10000 10000 Misc Pumps 1 6595 6595 Subtotal 63088 First 10kVA 10000 Balance at 40%21235 SUBTOTAL 31235 Air Conditioning Eqpt Chillers 1 8400 8400 Non Simultaneous with Snow melting and humidifiers Fan Coil Units 1 7245 7245 Non Simultaneous with Snow melting and humidifiers A/C Total 15645 29160 Snow Melting and Humidifiers Total SUB TOTAL 60395 VA 120/240V 1ph 3w 252 A 20% Spare Capacity 12079 TOTAL 72474 VA 120/240V 1ph 3w 302 A