HomeMy WebLinkAboutboyd application 7-25.pdf Department of Community Development 75 South Frontage Road West Vail,CO 81657 TOWN OF V IL ' Tel: 970-479-2128 Community Development www.vailgov.com Department Development Review Coordinator WINDOW REPLACEMENT PERMIT APPLICATION (This permit is applicable to one and two family dwelling units only) (Permit fee=standard building fees and design review fee) Project Information Type Owner Name: Tania Boyd Yp of Building: One Family( Two Family(Duplex)(0) Multi-Family( Parcel#: 2103-114-06-002 (For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit Submittal Requirements: www.eaglecounty.uslpatie) • Joint Property Owner Written Approval Letter(duplex or multi-family HOA) Project Street Address: • Two(2)plan sets indicating: 2249 Chamonix Lane 2 • Floor plans showing window location(s)and eleva- (Number) (Street) (Unit#) tions(window schedule may be substituted for eleva- tions) Contractor Information • Emergency egress requirements in bedrooms • Size of windows and openings Business Name: The Home Depot at Home Services • U-Value of windows 9500 W. 49th Ave. Suite #A-100 • Material,cut sheets and color of windows(must Business Address: match style and color of building) Wheat Ridge CO 80033 • Full view elevation photos of all sides of building City g state: P. (3) Replacement Jules Landis Detailed Scope and Location of Work: Contact Name: windows and (1) patio door, like tor like. Contact Phone: 720-496-7322 New windows:Andersen "Flbrex" -color "Sand Contact E-Mail: copermits@gmail.com Tone (use additional sheet if necessary) Applicant Information(fill in if different from contractor) Jules Landis Valuation Applicant Name: Work Included Plans Included of Work Applicant Phone: 720-496-7322 Electrical ()Yes ( No ()Yes ONo Applicant E-Mail: copermits@gmail.com ®NoMechanical ( Yes ()Yes ONo I hereby acknowledge that I have read this application,filled out in Plumbing (0Yes (OW 0Yes ONo full the information required,completed an accurate site plan, and state that all the information as required is correct. I agree to 'Building (0Yes ONo °Yes ONo $7,524 comply with the information and site plan,to comply with all Town ordinances and state laws, and to build this structure accordingto Value of all work being7,524 ' performed: $ the town's zoning and subdivision codes, design review approval, (value based on IBC Section 109.3&IRC Section 108.3) International Building and Residential Codes and other ordinances of the Town applicable thereto. Date Received: X Jules Landis Owner/Owner's Representative Signature Required(typed or digital signature) (44 Checking this box indicates you are electronically signing this application and agree to the above statement. For Office Use Only: ®Project#: Fee Paid: Received From: Building Permit#: Cash Check# CC: Visa/MC Last 4 CC# Auth#: Lot#: Block# Subdivision: 12-Sep 20 May 3rd 2016 The Board of Directors of Brandywine Trace Condominium Association gives permission to Ms Tania Boyd of Unit 2 to install replacement wi is ws in her condominium. Tania Boyd Brandywine Trace President ...ipagr,jre Michael Spiers Brandywine Trace Treasurer Jerry Kurtz Brandywine Secretary ) /(-144-• =7, Pir \VF'' Cr3 ,Ct I, rrn ti 10 _ vri (----- 0,, , A\ 4" PXVIP PWOr0 PHD?) Boyd Windows - Room Floor Window Type Width Height Sill Height U-value f Living Room 1 3 Panel Slider(1/3) 71.00in 63.00in 36" 0.26 Bedroom 1 Slider 49.00in 41.00in 48" 0.26 1: //31Bedroom#2 1 Slider 49.00in 41.00in 48" 0.26 (41Kitchen 1 Patio Door 72.00in 80.00in 0" 0.26 s../ Line Item#: 0001 Line Item Qty: 1 Initial: Location: `� _.._..__...__ _�.^...._.__...._._._._._..._. ROSize=5'11 1/2"W x 5'3 1/2"H Unit Size:-5'11"Wx5'3"H - 100 Series,100GX0X Single Units Unit Code/Item Size: 100GX0X5'11"x 5'3"'EQ(Custom) I, � Operation/Handing:XOX {� Frame Option: No Flange ),i I Exterior Color: Sandtone Interior Color: Sandtone - L___._.`I Glass Type(Left Sash): Low.ElHeatLock Tempered Glass -�� =_ Glass Type(Center Sash): Lbw E Heatlock Tempered Glass Glass Type(Right Sash): Low E HeatLock Tempered Glass Insect Screens:insect Screen,Sandtone Lock Color:Sandtone Zone:None1 ono U-Factor:0.26, SHGC;0,31 Line item#: 0005 Line Item Oty: t Initial: Location: 1,1\.‘\\17L .-$ 5 ROSize=4'11/2"Wx3'51/2"H Unit Size==4'1"Wx3'5"14 100 Series, 100GXO Single Units I Unit Code/Item Size: 100GX04'1"x 3'5"(Custom) I -÷ I Operation/Handing:XO Frame Option: No Flange '��^ �C) Exterior Color: Sandtone jv Interior Color: White Glass Type(Left Sash): Low E HeatLock Glass Glass Type(Right Sash): Low E HeatLock Glass Insect Screens:Insect Screen,Sandtone Lock Color:White Zone:None U-Factor:0.26, SHGC:0.31 -.-->- -,� �, .�.,- -... :Lgip,-r-... A .ur. ,_, ...---.1,..2-,..-C.......,.,1,....,= ,... Lticalron`__`--_—_._...-._—.__. _.._.._-_-___, ROSize-6'03/4"Wx6'81/2"H Unit Size=6'0"Wx6'8"H _ c 100 Series, 100GD2P 2 Panel _ ! ,_—.„- e _„—:,... --__..,..1 ( Unit Code/Item Size: 100GD2P6'0"x 6'8"(Custom) I I Operation/Handing:SR Frame Option: No Flange Exterior Color: Sandtone I1 Interior Color: Sandtone f Glass Type(Left Sash): Low E HeatLock Tempered Glass L__...._...._.) I L.....__...._,._1 Glass Type(Right Sash): Low E HeatLock Tempered Glass e ,-_1:•_.:- Insect Screens:Gliding Insect Screen,Sandtone Hardware:Tulsa-Trimset Hardware Style&Finish:Tulsa,Sandtane/Sandtone Auxiliary Lock Finish; Sandtone Exterior Keyed Lock Finish: Sandtone Zone:None aptitU-Factor:0.25, SHGC:0,32 ANDERSEN 100 SERIES • • 1 PANEL SLIDER (1 PNL) Sizes are Tip-to-Tip For MIN/MAX&Egress,Round UP measurement to NEXT WHOLE NUMBER NOTE:Egress requirements apply only in Bedrooms and habitable Basements MAX UI 143 ® ► WIDTH 231/2 24 25 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 71 1/2 111/2 AAA 1 e UK• .'7641M01 ROM OUR is �e+s xt 12 a a r rt 1 d { r 3 i Does Not Meet Egress Code tet. a v ' ffge s, f u o Requirements g INF l,. tc S 'i ,t.Jl x i V S 0 29 N mat a k ° '1 1 7 S . 1 30 g2'r r # r gltli f9 t a 31 Ik° Fytr N1j � ff?e/ 32 j i ria s:VV OAk L., tk ��81,00 ' • 33r11;04,', 3 Y we 34 SRI x 35 r f Meets 6 Sq Ft Ground 36 : r &ew.z.0 ,;; ;6. Floor Egress Exception REF G 37 H 38 39 t 40 [13.kW,P4U10:41 1p tag . 42 :W.A0r Meets 5.7 Sq Ft Egress 43 "V;16141 r Requirements 44 < • 45 ' fr 71 1 - £' u ai . 711/2 r F - ; Does Not Meet Egress Code Requirements MI Meets 5 Sq Ft Ground Floor Egress Exception IMO Meets 5.7 Sq Ft Egress Requirements 09-02-13 6 � il /�i I e dti � 14y �� eb r , ,WINOWS"M"RS 1 Anciersen. 10,,,..,,,, - _, ",,,,„,,,..„..,,:,,,,,,„,....„...,,,:,„:,, ,-,,,,,,, ....„ ,...„„„,,,.,.....,,,,...,,.,,.....,,,,,,, ,..„,,,..,.. „,,,...,,,,„.„,...„ ,..„,,,,,,..,,,„,,,,,,,,,,,,,,,A14"1,,,6r,„,;;;$,',4c1:4441%,,.'4.4,,,.'"(40;&al.f,tgill : '''' ' ,` etRViii�n w.�r1, 4,'rd 4 a5u�N���`` %ri r orf . PA,`t rr i iv €� 5"i, �.y ilf�ilR I i -Y� ,.); ti lU4` qI 'hln� lottrtittat, � rs 'K . :0 Andersen 100 Series awning windows are made with 5.4 . �Y 4 e .' our revolutionary Fibrex composite material to give . � <l h: , i n�4 - 4 you a window that is durable, environmentally smart, u a r , a `, . tegt.' , ,3a .,:: and energy efficient. 100 Series products are available � �4.f/ „ ' in deep, rich exterior colors that are low maintenance � a ;,'.';; ;;.::::k ?l0 —; 4 . 'j � x �� �.�, �s £ , 1 ��4 : and compliment virtually any architectural style. On the a;� t E C a . ie m ,_t you�i �� � a � ' ✓ �i �� � inside have the choice of low-maintenance white a ,iz� -,4,Z,',.,;:: or sandtone finish. For added style there is a wide =',.1f4 • � n 4kov. � � :'/1 range of grille patterns and patterned glass options. a,n fi 0' A^ " '; ; A ;wf �' 7,1 �� DURABLE :.:....-.2.-,..:,.,�at, � `nip �s ,, ''',1,:r • virtually maintenance-free r t •Rigorously tested to deliver ears'of smooth, reliable operation a, • Fibrex material construction provides long-lasting performance �lY U. ,R R �� ai' µfz .^fir ,rt , ,rz,"'�r` a° ' • Durable, low-maintenance finish won't fade,flake,blister,chalk or peel' §`ti • 1` d ti tom, 11 • Fibrex material is twice as stable and rigid as vinyl ENERGY EFFICIENT • Weather-resistant construction for greater comfort and energy efficiency I 3 � r, �f N L..,F ,i ', �It 45 , 'i y • kY 1? P, � �� Weatherstrippingis designed to seal .. . F mr 0 ; out drafts,wind and water c l • Fibrex material blocks thermal transfer nearly 700 times better than aluminum e.• ' • A variety of Low-E®glass options are available to C , control heating and cooling costs in any climate • Many 100 Series Awning Windows have options that achieve ENERGY STAR®version 6.0 certifications in all 50 states" '''� �,-, ,,., � BEAUTIFUL y. A,,, ?. 4 y- j,,, • Clean, attractive corner seams • Six exterior color options • Attractive matte finish interiors available in White or Sandtone • Add style with grilles or patterned glass EXTERIOR COLORS � �. y , White Sandtone Terratone Cocoa Bean Dark Bronze Black *Visit andersenwindows.com/warranty for details. o ,,, Visit andersenwindows.com to verify that the product and glass type are ENERGY STAR certified in your area. ,,, lifl `fir,, "ENERGY STAR"is a registered trademark of the U.S.Environmental Protection Agency. :us rom SIZES