HomeMy WebLinkAboutB16-0296_E3.0_1474657380.pdfT (E) PANEL UNIT #3 UNIT #3 200/2 M UNIT #2 200/2 M UNIT #1 200/2 M BASEMENT FIRST LEVEL SCALE: 1 DEMO ELECTRICAL ONE-LINE DIAGRAM NOT TO SCALE T UNIT #2 200/2 M UNIT #1 200/2 M BASEMENT FIRST LEVEL SCALE: 2 PROPOSED ELECTRICAL ONE-LINE DIAGRAM NOT TO SCALE (N) PANEL UNIT #3 SEC. 1 M NEW 600A, 208V, 1-PHASE, 2 SECTION PANEL NEW 600A, 208V, 1-PHASE DISCONNECT WITH 500A BUSSMANN JJN-500 FAST-ACTING FUSE. NEW UTILITY CT CABINET AND METER MOUNTED ON EXTERIOR OF BUILDING. COORDINATE EXACT LOCATION WITH ARCHITECT AND ELECTRIC UTILITY PRIOR TO ROUGH-IN. 500A (3W) 500A (3WG) 500A (3WG) GROUNDING ELECTRODE CONDUCTORS SIZED PER N.E.C. TABLE 250-66. WATER SERVICE I.A.W. N.E.C. 250-52(A)(1) 20 L.F. OF #4CU ENCASED IN MIN. 2" OF CONCRETE. I.A.W. N.E.C. 250-52(A)(3) BLDG. STEEL I.A.W. N.E.C. 250-52(A)(2) F1 F2 EXISTING TO REMAIN. 1 FLAG NOTES: 1 1 1 1 (N) PANEL UNIT #3 SEC. 2 WIRING SCHEDULE - COPPER AMPS (2WG) (3WG) 1Ø, 2 WIRE, GROUND 1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND 20 (2#12 & 1#12 G) 3/4"C (3#12 & 1#12 G) 3/4"C 30 (2#10 & 1#10 G) 3/4"C (3#10 & 1#10 G) 3/4"C 40 (2#8 & 1#10 G) 3/4"C (3#8 & 1#10 G) 3/4"C 50 (2#6 & 1#10 G) 3/4"C (3#6 & 1#10 G) 1"C 60 (2#4 & 1#10 G) 1"C (3#4 & 1#10 G) 1"C 70 (2#4 & 1#8 G) 1"C (3#4 & 1#8 G) 1 1/4"C 80 (2#2 & 1#8 G) 1"C (3#2 & 1#8 G) 1 1/4"C 90 (2#2 & 1#8 G) 1"C (3#2 & 1#8 G) 1 1/4"C 100 (2#1 & 1#8 G) 1 1/4"C (3#1 & 1#8 G) 1 1/2"C CONDUCTOR SIZES ARE BASED ON 60° TERMINATIONS LESS THAN 100A AND 75° TERMINATIONS GREATER THAN 100A CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). MECHANICAL EQUIPMENT SCHEDULE MARK DESCRIPTION VOLT / PHASE HP WATTS FLA MCA MOCP DISCONNECT/ FUSE SIZE FEEDER CIRCUIT SPECIFIC NOTES FC-1 FAN COIL UNIT #1 208/1 - 116 0.56 1.1 20 30A, 2P, NF (3#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-2 FAN COIL UNIT #2A 208/1 - 682 - 4.1 20 30A, 2P, NF (3#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-3 FAN COIL UNIT #3 208/1 - 116 0.56 1.1 20 30A, 2P, NF (2#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-4 FAN COIL UNIT #4 208/1 - 139 0.67 1.5 20 30A, 2P, NF (2#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-5 FAN COIL UNIT #5 208/1 - 137 0.66 1.2 20 30A, 2P, NF (3#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-6 FAN COIL UNIT #6 208/1 - 137 0.66 1.2 20 30A, 2P, NF (2#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-7 FAN COIL UNIT #7 208/1 - 272 1.31 2.7 20 30A, 2P, NF (2#12 & 1#12G) 3/4"C UNIT #3 - 43,45 FC-8 FAN COIL UNIT #8 208/1 - 116 0.56 1.1 20 30A, 2P, NF (2#12 & 1#12G) 3/4"C UNIT #3 - 43,45 CU-1 CONDENSING UNIT 208/1 - 5408 - 26.0 40 60A, 2P, NF (2#8 & 1#10G) 3/4"C UNIT #3 - 47,49 CU-2 CONDENSING UNIT 208/1 - 5408 - 26.0 40 60A, 2P, NF (2#8 & 1#10G) 3/4"C UNIT #3 - 51,53 H-1 HUMIDIFIER 120/1 - 3300 27.5 - 40 60A, 1P, NF (2#8 & 1#10G) 3/4"C SEE PLANS SG-1 MASTER BATH STEAM GENERATOR 208/1 - 10000 49.0 - 70 100A, 2P, NF (2#4 &1#8G) 1"C UNIT #3 - 52,54 SG-2 STEAM GENERATOR #2 208/1 - 12000 58.0 - 80 100A, 2P, NF (2#2 & 1#8G) 1"C UNIT #3 - 56,58 B-1 UNIT #3 BOILER 120/1 - 1224 - 10.2 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C SEE PLANS P-1 DHW RECIRC PUMP 120/1 - 85 0.7 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C UNIT #3 - 59 P-2 BOILER CIRC PUMP 120/1 - 139 1.7 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C - (1) P-3 HEATING WATER CIRC 120/1 - 442 1.5 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C UNIT #3 - 61 P-4 WH PUMP 120/1 - 360 2.3 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C UNIT #3 - 59 GF-1 GLYCOL FEEDER 120/1 - 50 0.4 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C UNIT #3 - 61 EF-1 CEILING EXHAUST FAN 120/1 - 32.4 0.3 - 20 1P MOTOR RATED SWITCH (2#12 & 1#12G) 3/4"C UNIT #3 - 60 GENERAL NOTES: A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION. B. PROVIDE PHASE PROTECTION FOR ALL THREE PHASE MOTORS ABOVE 7-1/2 HP. C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3R RATING. D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C. SPECIFIC NOTES: (1) PUMP SHALL BE FED FROM B-1. (2) (3) (4) SHORT CIRCUIT / VOLTAGE DROP CALCULATION SUMMARY POINT TAG VOLTAGE / PHASE LENGTH (FT) COPPER / ALUMINUM CONDUIT WIRE SIZE # OF SETS FEEDER VOLTAGE DROP (%) TOTAL VOLTAGE DROP (%) Isc AVAILABLE UPSTREAM Isc (FAULT) F1 DISCONNECT 208V, 1Ø 25 350 2 0.3% 0.3% 99,500 58,141 F2 PANEL 'UNIT #3' 208V, 1Ø 110 A S 350 2 1.4% 1.8% 9,975 7,440 ** PER THE UTILITY, THE MAXIMUM AVAILABLE (SYMMETRICAL) FAULT AT THE SECONDARY SIDE OF THE SERVICE TRANSFORMER IS 99,500 AMPS, ASSUMING A 500 KVA TRANSFORMER. SHORT CIRCUIT CALCULATIONS ARE FURNISHED FOR ALL FAULT LEVELS ABOVE 10,000 AMPS @ 208 VOLT (14,000 AT 480 VOLT). ANY FAULT CURRENT BELOW THIS LEVEL IS CONSIDERED SAFE FOR THE ELECTRICAL SYSTEM TO CLEAR OR EQUIPMENT IS BUILT TO WITHSTAND THIS LEVEL OF FAULT SAFELY. PANEL: (N)UNIT #3 - SEC. 1 VOLTAGE: 120/208V, 1PH, 3W MINIMUM BUS: 600 LOCATION: MECHANICAL 101 MAIN: MLO MOUNTING: RECESSED MINIMUM AIC: 10,000 AIC NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO. POLE TRIP A B TRIP POLE 1 312 R (1) REC - FOYER/MUD RM 1 20 + 20 1 R (1) REC - LAUNDRY 312 2 3 312 R (1) REC - LIVING RM 1 20 + 20 1 A (1) WASHER 1500 4 5 312 R (1) REC - DINING 1 20 + 30 2 A DRYER 2496 6 7 312 R (1) REC - KITCHEN ISLAND 1 20 + A 2496 8 9 312 R (1) REC - KITCHEN COUN 1 20 + 20 1 R (1) REC - BEDROOM 2 312 10 11 312 R (1) REC - KITCHEN COUN 1 20 + 20 1 R (1) REC - BATHROOM 2 312 12 13 1500 R (1) REC - SMALL APP 1 20 + 20 1 R (1) REC - MASTER BED 312 14 15 1500 R (1) REC - SMALL APP 1 20 + 20 1 R (1) REC - MASTER BATH 312 16 17 1500 A (1) DISHWASHER 1 20 + 20 1 R (1) REC - MECHANICAL 312 18 19 1500 A (1) DISHWASHER 1 20 + 20 1 R (1) REC - LOFT 312 20 21 1500 A (1) GARBAGE DISP 1 20 + 20 1 R (1) REC - LOFT BAR 312 22 23 2496 A RANGE 2 30 + 20 1 A (1) UC REF 1000 24 25 2496 A + 20 1 A (1) DISHWASHER 1500 26 27 1500 A HOOD 1 20 + 20 1 R (1) REC - LOFT BATH 312 28 29 1500 A (1) REF/FRZR 1 20 + 20 1 R (1) REC - BEDROOM 3 312 30 31 312 R (1) REC - PANTRY 1 20 + 20 1 R (1) REC - BATHROOM 3 312 32 33 312 R (1) REC - POWDER 111 1 20 + 20 1 R (1) REC - BEDROOM 4 312 34 35 312 R (1) REC - 1ST FLR DECK 1 20 + 20 1 R (1) REC - BATHROOM 4 312 36 37 312 R (1) REC - 2ND FLR DECK 1 20 + 20 1 R (1) REC - 3RD FLR DECK 312 38 39 SPARE 1 20 + 20 1 SPARE 40 41 SPARE 1 20 + 20 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 1027 1027 125% 1284 B. (R) RECEPTACLES 10488 180 10668 NEC 220 10334 C. (LM) LRG. MOTOR 0 25% 0 D. (M) MOTORS (ALL) 0 11980 11980 100% 11980 E. (E) EQUIPMENT 0 45870 45870 100% 45870 SPECIFIC NOTES: (A) APPLIANCES 21484 0 21484 0 21484 (1) PROVIDE AFCI TYPE CIRCUIT BREAKER. PANEL TOTAL (KVA): 91.0 (2) (3) PANEL TOTAL (A): 437 (4) (5) PANEL: (N)UNIT #3 - SEC. 2 VOLTAGE: 120/208V, 1PH, 3W MINIMUM BUS: 600 LOCATION: MECHANICAL 101 MAIN: MLO MOUNTING: RECESSED MINIMUM AIC: 10,000 AIC NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO. POLE TRIP A B TRIP POLE 43 858 E FAN COIL UNITS 2 20 + 40 1 E H-1 (FOR FC-1) 3300 44 45 858 E + 40 1 E H-1 (FOR FC-5) 3300 46 47 2704 M CU-1 2 40 + 40 1 E H-1 (FOR FC-6) 3300 48 49 2704 M + 40 1 E H-1 (FOR FC-8) 3300 50 51 2704 M CU-2 2 40 + 70 2 E SG-1 5000 52 53 2704 M + E 5000 54 55 1224 E B-1 1 20 + 80 2 E SG-2 6000 56 57 1224 E B-1 1 20 + E 6000 58 59 445 M P-1/P-4 1 20 + 20 1 M EXHAUST FANS 227 60 61 492 M P-3/GF-1 1 20 + 20 2 E (1)HEAT TRACE 1115 62 63 48 E SMOKE DETECTORS 1 20 + E 1115 64 65 620 L LGT - LVL 1 LIGHTING 1 20 + 20 2 E (1)HEAT TRACE 1094 66 67 407 L LGT - LVL 2/3 LIGHTING 1 20 + E 1094 68 69 180 R REC - SERVICE ENT 1 20 + 20 1 SPARE 70 71 1320 E LVL 1 SHADES 1 20 + 20 1 SPARE 72 73 720 E LVL 2 SHADES 1 20 + 20 75 SPARE 1 20 + 20 1 SPARE 76 77 SPARE 1 20 + SPACE 78 79 SPARE 1 20 + SPACE 80 81 SPARE 1 20 + SPACE 82 83 SPACE + SPACE 84 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 1027 1027 125% 1284 B. (R) RECEPTACLES 180 180 NEC 220 180 C. (LM) LRG. MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 11980 11980 100% 11980 E. (E) EQUIPMENT 45870 45870 100% 45870 SPECIFIC NOTES: (A) APPLIANCES 0 0 (1) PROVIDE 30-mA GFCI CIRCUIT BREAKER PANEL TOTAL (KVA): 59.3 (2) (3) PANEL TOTAL (A): 285 (4) (5) LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING RECESS DEPTH LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC NOTES QTY TYPE A 5" LENSED RECESSED DOWNLIGHT FOR FLAT CEILING RECESSED 7.5" - LED W/ UNIT 10.2 120 HALO H550RICAT - ML5606935 - 593WB B 5" LENSED RECESSED DOWNLIGHT FOR SLOPED CEILINGS RECESSED 7.5" - LED W/ UNIT 10.2 120 HALO H550RICAT - ML5606935 - 594WB GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS. C. ALL FLUORESCENT LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE SPECIFIC NOTES: (1) (2) (3) (4) EXISTING UTILITY TRANSFORMER EXISTING UTILITY TRANSFORMER SERVICE WIRING SCHEDULE AMPS ALUMINUM (3W) GROUNDING ELECTRODE CONDUCTOR 1Ø, 3 WIRE W.P. M.F. C.E.C. G.RING G. ROD 500 2[(3-350 KCMIL) 2 1/2"C] #1/0 CU #1/0 CU #1/0 CU #1/0 CU #6 CU CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). ABBREVIATIONS: W.P. - WATER PIPE; M.F. - METAL FRAME OR STRUCTURE; C.E.C. - CONCRETE ENCASED ELECTRODE; G.RING. - GROUND RING; G.ROD - GROUND ROD, PIPE OR PLATE ELECTRODE WIRING SCHEDULE - ALUMINUM AMPS (3WG) 1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND 500 2[(3-350 KCMIL & 1#1/0 G) 3"C] CONDUCTOR SIZES ARE BASED ON 75° TERMINATIONS. CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). Sheet Title: Sheet No: Project No: Revisions: Issue Dates: Seal © 2016 Judge + Associates Architects + Planners 1509.00 Red Lion Condo 3 Renovation 304 Bridge St, Vail Village, CO Judge + Architects + Planners Vail CO 81658.1734 (970) 949.7034 Post Office Box 1734 Edwards, CO 81632 105 Edwards Village Blvd, Suite G104 email: general@vagarchitects.com Associates H "E" 03.14.16: PEC Meeting "H" 04.20.16: 40% DD E3.0 Electrical 09/23/16