SCALE: PROPOSED SECOND FLOOR PLUMBING PLAN 1/4" = 1'-0" A 6 4.8 4.6 3.9 3.1 2 1 E D C RADIANT ZONE 14 RADIANT ZONE 12 INSTALL NEW CW/HW/HWC BRANCHES FROM MAIN PLUMBING DSTIRBUTION LINES TO (N) BATHROOM FIXTURES. REARRANGED BATHROOM FIXTURES. RE-ROUTE WASTE & VENT SYSTEMS TO MATCH NEW ARRANGEMENT. CONNECT CW, HW, & HWC PIPING TO (E) DISTRIBUTION PIPING SERVING THE ORIGINAL LAYOUT. NEW PLUMBING FIXTURE. CONNECT TO (E) WASTE 3" OR LARGER, (E) VTR 3" AND LARGER, PROVIDE NEW CW, HW, & HWC PIPING TO MECHANICAL ROOM WATER ENTRY AND WATER HEATER. 1 FLAG NOTES: 2 1. RE: M4.0 FOR CLEANOUT DIAGRAMS. 2. RE: M4.0 FOR ISLAND VENT DIAGRAM. 3. RE: M4.0 FOR TRAP PRIMER CONNECTION. 4. REFER TO THE PLUMBING FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 5. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER. 6. COORDINATE ROUTING OF CONDENSATE DRAIN LINES WITH ARCHITECT PRIOR TO INSTALLATION. 7. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 8. TERMINATE PLUMBING VENTS NOT LESS THAN 12" ABOVE ROOF. 9. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 10. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 11. ROUTE DOMESTIC HOT WATER RECIRC TO WITHIN 10 FEET OF ALL HOT WATER FIXTURES. CONNECT WITHIN 3 FEET OF 0.5 GPM AND LOWER FAUCETS. 12. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED. 13. ALL VALVES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN OTHERWISE UN-ACCESSIBLE LOCATIONS. PLUMBING NOTES: 1. ALL RE-USED (E) DUCTWORK SHALL BE INSPECTED FOR LEAKAGE AND CLEANED/SANITIZED. 2. ADDITIONAL STORM, HYDRONIC, DOMESTIC, WASTE AND VENT PIPING MAY BE ROUTED IN SPACE THAT IS NOT REPRESENTED, BUT IS TO REMAIN. OTHER SYSTEMS MAY EXIST WITHIN THE SPACE THAT ARE NOT REPRESENTED ON THESE DRAWINGS; MODIFICATIONS TO THESE SYSTEMS ARE NOT ANTICIPATED. 3. FIELD VERIFY ALL COMPONENTS PRIOR TO DEMOLITION. THE INFORMATION ON THIS SHEET WAS OBTAINED, IN PART, FROM HISTORIC DESIGN DRAWINGS. ONLY PORTIONS OF THE SYSTEMS WERE ACCESSIBLE FOR VISUAL CONFIRMATION DURING DESIGN PROCESS. 4. TEMPORARILY SEAL OR CAP PIPING TO BE RE-USED FOR LATER CONNECTION. 5. SEAL ALL OPEN DUCTS DURING CONSTRUCTION TO MITIGATE DUST AND DEBRIS FROM SYSTEM. CAP DUCTWORK IN LOCATIONS THAT ARE NOT BEING RECONNECTED. 6. REMOVE ALL DEMOLISHED COLD WATER, HOT WATER AND HOT WATER RECIRCULATION PIPING BACK TO BRANCH FROM MAIN TO ELIMINATE ALL DEAD ENDS IN DOMESTIC WATER PIPING. 7. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OF INFORMATION REPRESENTED IN THE DOCUMENTS VERSUS WHAT IS FOUND IN THE FIELD. 8. COORDINATE PATCHING AND REPAIRS OF WALLS, CEILINGS AND FLOORS WITH ARCHITECT. 9. PATCH STRUCTURAL OPENINGS IN FLOORS, WALLS AND ROOFS THAT WERE PREVIOUSLY OCCUPIED BY SYSTEMS AND EQUIPMENT DEMOLISHED UNDER THIS CONTRACT IN ACCORDANCE WITH STRUCTURAL ENGINEER'S REQUIREMENTS. DEMOLITION NOTES: 3 2 2 UNIT 3 RADIANT MANIFOLD SCHEDULE ZONE DESCRIPTION AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS MAX LOOP PRESSURE LOSS (FtWC) FLOOR COVERING 11 BATH 210 220 0.5 2 8 12 BEDROOM 209 240 0.6 2 8 13 LOFT 410 1.1 14 BATH 203 45 0.1 15 BEDROOM 3 175 0.5 2 6 16 BATH 3 65 0.2 1 3 MANUFACTURERS: * GENERAL NOTES: A: PROVIDE UPONOR 10" QUICK TRACK OR EQUAL. USE 5/16" TUBING TO LIMIT FLOOR ASSEMBLY HEIGHT. B: UNIT 2 RADIANT MANIFOLD SCHEDULE ZONE DESCRIPTION AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS MAX LOOP PRESSURE LOSS (FtWC) FLOOR COVERING 220 0.6 2 BATHROOM 234 126 0.3 MANUFACTURERS: * GENERAL NOTES: A: PROVIDE UPONOR QUICK TRACK OR EQUAL. USE 5/16" TUBING TO LIMIT FLOOR ASSEMBLY HEIGHT. B: RADIANT ZONE 11 RADIANT ZONE 13 RADIANT ZONE 15 RADIANT ZONE 16 3 3 3 3 UNIT 3 (N) BOILER FLUES AND COMBUSTION AIR PIPES UP TO ROOF CONCENTRIC TERMINATION. Sheet Title: Sheet No: Project No: Revisions: Issue Dates: Seal © 2016 Judge + Associates Architects + Planners 1509.00 Red Lion Condo 3 Renovation 304 Bridge St, Vail Village, CO Judge + Architects + Planners Vail CO 81658.1734 (970) 949.7034 Post Office Box 1734 Edwards, CO 81632 105 Edwards Village Blvd, Suite G104 email: general@vagarchitects.com Associates H "E" 03.14.16: PEC Meeting "H" 04.20.16: 40% DD M3.2 Floor Plan Proposed 09/23/16