HomeMy WebLinkAboutB16-0296_M4.0_1478898171.pdfWALL CLEANOUT DIAGRAM NO SCALE 1'-0" MAY EXTEND AS A WASTE OR VENT. CHROME WALLCOVER AND SCREW. PLUGGED TEE WITH CLEANOUT. WALL. FLOOR LINE. 1/8 C.I. BEND. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. MIN. HEIGHT PER MFR. BALL VALVE. TAKE-OFF FROM TOP OF CW PIPE. TRAP PRIMER VALVE, SIOUX CHIEF PRIME PERFECT OR EQUAL. DISTRIBUTION UNIT (FOR MULTIPLE DRAINS). 1 2 " TYPE K SOFT COPPER LINE(S) TO FLOOR DRAIN(S). QUANTITY AS REQUIRED. NO JOINTS BELOW GRADE. 1/2" DIAGRAM TRAP PRIMER CONNECTION NO SCALE FLOOR (E) WATER ENTRANCE DIAGRAM (TYPICAL UNIT) M NO SCALE DOMESTIC WATER SERVICE SHUT-OFF VALVE. 1"CW TO UNIT. REDUCED PRESSURE TYPE BACKFLOW PREVENTER. CERTIFIED TESTER TO TEST. 1" WATER METER WITH REMOTE READOUT. CONFIRM METER SIZE AND (E) CW PIPE SIZE. PRESSURE REDUCING VALVE (WATTS 223 OR EQUIV. SET @ 60 PSI). 1"CW SERVICE (CONTRACTOR TO CONFIRM (E) SIZE). : WATER METER AND BACKFLOW PREVENTER MUST BE MOUNTED HORIZONTALLY. PIPE THRU ROOF DIAGRAM NO SCALE 6" MIN. 24 GA. GALV. ROOF JACK W/ 6" FLANGE BY M.C., SET IN PLASTIC CEMENT BY G.C. PIPE BY M.C. 24 GA. GALV. STORM COLLAR BY M.C., CLAMP IN PLACE & CAULK WEATHERTIGHT. FINISHED ROOF FELTS BY G.C. SOLDERED LAP SEAM PIPE SLEEVE & CAULKING BY M.C. 2" MIN. ROOF 2 LAYERS OF FELT BY G.C. COOR'D ROOF PENETRATION AND SEALING WITH ROOF MANUFACTURER AND INSTALLING CONTRACTOR. B C E A HEAT PUMP REFRIGERANT PIPING SCHEMATIC NO SCALE D RS/L LINESETS BETWEEN OUTDOOR UNIT AND HEADER, TYP. 1. RS/L LINESETS NOT SHOWN ON PLAN. 2. SIZING PER MANUFACTURER. RS/L LINESETS BETWEEN BRANCH BOX AND INDOOR UNITS, TYP. HEADER AIR FLOW NO SCALE USE DUCT SEALANT OR GASKETED FITTING ON HIGH VELOCITY DUCT. CONICAL SPIN-IN FITTING W/ MANUAL DAMPER, HANDLE, & LOCK NUT. FLEX DUCT. WORM DRIVE S.S. CLAMP. DIAGRAM FOR LOW & HIGH VELOCITY DUCTWORK EXCEPT UPSTREAM OF VAV BOXES. OMIT DAMPER & FLEX DUCT UPSTREAM OF VAV BOXES. ROUND DUCT TAKE-OFF DIAGRAM COIL PIPING DIAGRAM NO SCALE (DC-2, DC-7) COIL : 1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH AS DUCT COILS. 2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 4. 3-WAY VALVE WITH COIL RETURN PIPED TO NORMALLY OPEN PORT FOR HEATING AND NORMALLY CLOSED PORT FOR COOLING. L MANUAL AIR VENT AT HIGHEST POINT IN PIPING. STRAINER WITH BLOWDOWN VALVE AND CAP. SUPPLY RETURN 3-WAY (DIVERTING VALVE) NO SCALE CONTROL VALVE. MANIFOLD BOX (WALL MOUNTED FOR RADIANT; LOCATED IN SLAB OR LANDSCAPE BOX FOR SNOWMELT). MANUFACTURER'S MANIFOLD ASSY. LOOP BALANCE/ISOLATION VALVE MANUFACTURER'S MANIFOLD ASSEMBLY WITH REVERSE RETURN PIPING. RADIANT/SNOWMELT TUBING. LOOP QUANTIITY AS REQUIRED. 1. PROVIDE MANUFACTURER'S MANIFOLDS AND ISOLATION VALVES WITH PIPING. 2. FOR EXTERIOR MANIFOLD LOCATIONS PROVIDE WATERPROOF MANIFOLD BOX OR WATERPROOF CONTROL VALVE. TO PIPING MAINS AIR VENT AT HIGH POINTS, TYPICAL. MANIFOLD BALANCE VALVE. RADIANT MANIFOLD PIPING DIAGRAM REQUIRED. CABLE OR AS 24" STANDARD SUPPLY DIFFUSER BALANCE DAMPERS ADJUSTS WITH r" NUTDRIVER SPECIFY OPTIONAL SCREWDRIVER TIP IF LESS THAN y" CLEAR ACCESS. NO SCALE ROUND DAMPER PLENUM ADJUSTABLE MOUNTING CLAMP DIFFUSER TAKE-OFF AS REQ. DAMPER IF H<8" OPPOSED BLADE DAMPER IF H>=8" SINGLE BLADE END BEARING W H ACCESSIBLE BRANCH DUCT DAMPER NON-ACCESSIBLE BRANCH DUCT DAMPER FLOOR DIFFUSER SIMILAR. CEILING DIFFUSER SHOWN. NOTE: INSULATED SUPPLY AIR PLENUM. G K J THRU ROOF DIAGRAM DRYER VENT NO SCALE STORM COLLAR/ COUNTER FLASHING. SEAL TO DUCT. MEMBRANE, INSULATION, FLASHING, ETC. LONG RADIUS ELBOW. FULLY WELDED CURB CAP, SIMILAR TO TRANSITION. TIGHT TO, BUT NOT FASTENED TO DUCT. PREFAB, INSULATED ROOF CURB WITH TREATED WOOD NAILER. SUPPORT DUCT FROM STRUCTURE. DRYER VENT CAP W/ BACKDRAFT DAMPER. GOOSENECK DIAGRAM NO SCALE 135° SPOT WELD REINFORCING ANGLE. NUT & BOLT. BIRD SCREEN FRAME. DUCT SIZE PLUS 25%. 1/4" SCREEN. 20" MIN. FLASHING AND COUNTER FLASHING. 12" MIN. 14" MIN. COOR'D ROOF PENETRATION WITH ROOF MANUFACTURER. N Q SMS/R OR HWS/R BALANCE TO COIL GPM. BALANCE IN FIELD BASED ON TAB EXERCISES. HEADER DOMESTIC WATER HEATER PIPING DIAGRAM NO SCALE (SIDEARM) HW TO FIXTURES. COLD WATER SUPPLY. HWC FROM FIXTURES. DIAPHRAGM TYP. EXPANSION TANK, . RELIEF VALVE, PIPE INDIRECT TO FLOOR DRAIN. DOMESTIC HOT WATER RECIRC PUMP WATER HEATER. D A HWR HWS S P 1-1/2" 1-1/2" 3/4" GAS PIPING ONE-LINE DIAGRAM NO SCALE M M 2 PSI DISCHARGE. (E) GAS PIPING TO REMAIN CONTRACTOR TO TEST PIPING FOR REUSE AND CONFIRM (E) PIPE LENGTH TO METER IS LESS THAN 150' AND PIPE SIZE IS 1" OR LAGRER. 100 FT, 1386 CFH, 2-1/2" KITCHEN RANGE 129 MBH 161 CFH 1" BBQ 90 MBH 112 CFH 1" LIVING RM FP 60 MBH 75 CFH 3/4" (N) GAS UTILITY METER/PRV ASSEMBLY. NO SCALE LINED S.A. DUCT UNLINED ALUMINUM DUCT CONDENSATE TRAP SHORT ABSORPTION STEAM DISTRIBUTION MANIFOLD PROVIDED BY HUMIDIFIER MANUFACTURER. SLOPE DRAIN TO NEAREST APPROVED RECEPTOR. SLOPE 1" DRAIN TO NEAREST APPROVED RECEPTOR. 1/2" H BOILER 399 MBH 500 CFH 1-1/2" BOILER 399 MBH 500 CFH 1-1/2" PRV IN UNIT 3 MECHANICAL ROOM, REDUCE PRESSURE FROM 2 PSI TO 11" WC. MASTER BR FP 60 MBH 75 CFH 3/4" FAN COIL UNIT INSTALLATION NO SCALE D SA FAN COIL UNIT D OSA FILTER W/ ACCESS PANEL. ACOUSTICAL LINING. RA DUCT. CONDENSATE DRAIN. PIPE INDIRECT TO APPROVED RECEPTOR (PROVIDE MIN. 2" DEEP TRAP). SHEET METAL DRAIN PAN. 3/4" SECONDARY DRAIN TO APPROVED RECEPTOR. PIPE INDIRECT TO FLOOR DRAIN ON SINK TAIL PIECE, TYP. ROUND HANGER ROD TYP. SPRING VIBRATION ISOLATORS, TYP. DOUBLE LOCKNUT. 1. RETURN AIR PLENUM FULL SIZE OF UNIT CONNECTION. 2. MOTORIZED OSA & RA DAMPERS NOT NECESSARILY USED IN ALL APPLICATIONS CEILING MOTORIZED DAMPERS ON UNIT WITH DCV, ECONOMIZER, OR MAKE-UP AIR APPLICATONS OTHERWISE MANUAL DAMPER. F MOTORIZED DAMPER RESILIENT ANCHOR DETAIL NO SCALE ANCHOR BOLT. EQUIPMENT BASE MASON INDUSTRIES TYPE HG GROMMET. STEEL WASHER 3/4" MASON INDUSTRIES SUPER W PAD. FLOOR. R P 1 H 1 CU 1 CU 2 FC 1 FC 2 FC 3 FC 4 FC 5 FC 6 FC 7 FC 8 : 1. PROVIDE ACCESSIBLE OR KEYED SHUT OFF VALVE AT EACH GAS APPLIANCE. 2. GAS LOADS ARE ESTIMATES OR BASED ON PRELIMINARY INFORMATION. CONTRACTOR TO VERIFY EXACT GAS LOADS AND INFORM ENGINEER OF ANY LOADS HIGHER THAN ESTIMATED PRIOR TO INSTALLATION. 3. GAS PIPE SIZING BASED ON 100 FT TOTAL DEVELOPED LENGTH, 11"WC INLET PRESSURE, 0.5 IN.WC. PRESSURE DROP AND SCH. 40 METALLIC PIPE. 4. CALCULATIONS BASED ON A NATURAL GAS CONTENT OF 800 BTU/CF. 75 CFH 3/4" 165 CFH 1" 225 CFH 1-1/4" 386 CFH 1-1/2" 886 CFH 2" REFER TO DIAGRAM 1, SHEET M4.1, FOR 2"HWS/R CONTINUATION. 2" 2" Sheet Title: Sheet No: Project No: Revisions: Issue Dates: Seal © 2016 Judge + Associates Architects + Planners 1509.00 Red Lion Condo 3 Renovation 304 Bridge St, Vail Village, CO Judge + Architects + Planners Vail CO 81658.1734 (970) 949.7034 Post Office Box 1734 Edwards, CO 81632 105 Edwards Village Blvd, Suite G104 email: general@vagarchitects.com Associates H "E" 03.14.16: PEC Meeting "H" 04.20.16: 40% DD M4.0 Diagrams Mechanical 09/23/16