HomeMy WebLinkAboutB16-0330_A1.3 Details_1478903978.pdfASSUMED EXIST. PERIMETER DRAIN
EXIST. FOOTING
EXIST. CONC. FOUNDATION WALL
NEW SLOPED STONE PATIO OVER SETTING BED
W/ HEAT TUBING OVER WATERPROOFING OVER
SHEATHING OVER SLOPED JOISTS. SLOPE IN. 1
4"
PER FOOT
EXIST. DOOR TO REMAIN. REPLACE FLASHING
AND EXTEND OVER STONE
WHERE FOUNDATION WALL IS LOWER THAN
GRADE, ADD BLOCKING BETWEEN JOISTS AND
NEW WATERPROOFING UP WALL MIN. 12" AND
OVER EXIST. FOUND. WATERPROOFING MIN. 12".
FLASHING OVER WATERPROOFING TO TURN
DOWN AT STONE. SEALANT AT CAULKING
NEW FOUNDATION WALL W/ STONE VENEER
3'-0" MIN. 4'-6"
1'-3" 3'-0"
LOWER LEVEL ELEV.
81'-10"
UPPER LEVEL ELEV.
90'-10"
PATIO ELEV.
89'-10"
1'-3"
1'-0"
TYP.
T.O. WALL
RE: PLAN
1
2"
C KRUEGER
ARCHITECTURE
& DESIGN PO box 8332
Avon CO 81620
970.390.0968
pavan@kruegerarchitecture.com
COPYRIGHT 2016
KRUEGER ARCHITECTURE & DESIGN
ISSUED FOR: DATE:
DRAWN BY: 327 ROCKLEDGE
RENOVATION
UNIT B, PARCEL A, RESUB. OF LOTS 14 & 17, BLOCK 7, FILING 1, VAIL,
COLORADO
SHEET SCALE:
PROJECT : 327 ROCKLEDGE
PK
PRICING 2-15-16
A1.3
NEW SITE PLAN
SCALE:
DETAIL AT PATIO/STEPS/PLANTER
1
1/2" = 1'-0"
A1.3
PRICING 6-21-16
SCALE:
DETAIL AT NEW STONE LANDING 2
1" 1'-0"
A1.3
DRB/PERMIT 7-19-16
SCALE:
TYPICAL SITE WALL DETAIL
3
1" 1'-0"
A1.3
09/12/16